Provide us with a few simple details, and our in-house engineers can produce your zone plan chart.
| Product | Price (ex VAT) | Quantity | Total (ex VAT) |
|---|---|---|---|
|
|
£
ex VAT
|
£0.00
|
Code: FDS100/359
INC VAT
Code: FDS100/359
The Apollo 55000-199APO AlarmSense CS High Temperature Heat Detector with sounder beacon base provides integrated heat detection with combined audible and visual alarm signalling.
This package includes the Apollo 55000-193 CS High Temperature Heat Detector and the Apollo 45681-509 sounder beacon base, delivering detection and warning from a single point. The CS heat detector operates at a fixed temperature of 90°C, making it suitable for environments with high ambient temperatures or rapid temperature fluctuations, such as boiler rooms and plant areas.
The included sounder beacon base provides both a selectable audible output and a visual warning, improving alarm awareness in noisy or complex environments.
As part of the AlarmSense range, the unit connects to a two-wire system that allows detectors, sounders and call points to be installed on a single cable pair, reducing wiring complexity and simplifying installation.
Apollo 55000-199APO
High Temperature Heat Detector
Can be used for applications where smoke detectors are unsuitable
Ideal environments that are dirty or smoky under normal conditions
CS detectors are ideal for use in environments with rapid temperature fluctuations such as boiler rooms
360 visibility of LEDs
Reduction of false alarms
Quick and simple installation
Visual and audible warning
AlarmSense priority/non priority signal recognition
Detects the removal of a detector head and reports a fault
Quick and simple installation
Provides audible signal and detection at one point
High and low volume ranges
Specification | Value |
|---|---|
Detection principle | Heat sensitive resistance using a single NTC thermistor |
Sampling frequency | Once every four seconds |
Supply voltage | 9 Vdc to 33 Vdc |
Supply wiring | Two wire supply, polarity insensitive |
Quiescent current at 15 V | < 50 µA |
Alarm current (2–8.5 V) | < 1.5 mA |
Alarm current (10.5–15 V) | 25 ± 2 mA |
Alarm current (18–24 V) | < 1.5 mA |
Alarm current (33 V) | < 2 mA |
Maximum reset voltage | 2 V |
Reset time | 1 second |
Maximum supply interruption time | 40 ms |
Operating temperature (A1R) | -40°C to +50°C |
Operating temperature (CS) | -40°C to +80°C |
Humidity | 0% to 95% RH (no condensation or icing) |
IP Rating | Designed to IP44 |
Standards and approvals | EN 54-5, CPR and FG |
Dimensions | 100 mm diameter × 42 mm height |
Dimensions in base | 100 mm diameter × 50 mm height |
Weight | 80 g (detector) |
Materials – Housing | White flame-retardant polycarbonate |
Materials – Terminals | Nickel plated stainless steel |
The Apollo 55000-199APO AlarmSense CS High Temperature Heat Detector with sounder beacon base provides integrated heat detection with combined audible and visual alarm signalling.
This package includes the Apollo 55000-193 CS High Temperature Heat Detector and the Apollo 45681-509 sounder beacon base, delivering detection and warning from a single point. The CS heat detector operates at a fixed temperature of 90°C, making it suitable for environments with high ambient temperatures or rapid temperature fluctuations, such as boiler rooms and plant areas.
The included sounder beacon base provides both a selectable audible output and a visual warning, improving alarm awareness in noisy or complex environments.
As part of the AlarmSense range, the unit connects to a two-wire system that allows detectors, sounders and call points to be installed on a single cable pair, reducing wiring complexity and simplifying installation.
Apollo 55000-199APO
High Temperature Heat Detector
Can be used for applications where smoke detectors are unsuitable
Ideal environments that are dirty or smoky under normal conditions
CS detectors are ideal for use in environments with rapid temperature fluctuations such as boiler rooms
360 visibility of LEDs
Reduction of false alarms
Quick and simple installation
Visual and audible warning
AlarmSense priority/non priority signal recognition
Detects the removal of a detector head and reports a fault
Quick and simple installation
Provides audible signal and detection at one point
High and low volume ranges
Specification | Value |
|---|---|
Detection principle | Heat sensitive resistance using a single NTC thermistor |
Sampling frequency | Once every four seconds |
Supply voltage | 9 Vdc to 33 Vdc |
Supply wiring | Two wire supply, polarity insensitive |
Quiescent current at 15 V | < 50 µA |
Alarm current (2–8.5 V) | < 1.5 mA |
Alarm current (10.5–15 V) | 25 ± 2 mA |
Alarm current (18–24 V) | < 1.5 mA |
Alarm current (33 V) | < 2 mA |
Maximum reset voltage | 2 V |
Reset time | 1 second |
Maximum supply interruption time | 40 ms |
Operating temperature (A1R) | -40°C to +50°C |
Operating temperature (CS) | -40°C to +80°C |
Humidity | 0% to 95% RH (no condensation or icing) |
IP Rating | Designed to IP44 |
Standards and approvals | EN 54-5, CPR and FG |
Dimensions | 100 mm diameter × 42 mm height |
Dimensions in base | 100 mm diameter × 50 mm height |
Weight | 80 g (detector) |
Materials – Housing | White flame-retardant polycarbonate |
Materials – Terminals | Nickel plated stainless steel |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.