Provide us with a few simple details, and our in-house engineers can produce your zone plan chart.
| Product | Price (ex VAT) | Quantity | Total (ex VAT) |
|---|---|---|---|
|
|
£
ex VAT
|
£0.00
|
1 item added to basket
Apollo 55000-193APO AlarmSense CS High Temperature Heat Detector | Standard Base Set
Code: FDS410/043
INC VAT
Code: FDS410/043
The Apollo 55000-193APO AlarmSense CS High Temperature Heat Detector is a static heat detector designed to operate at a fixed temperature of 90°C. It is suited to environments where standard heat or smoke detection may not be appropriate due to high ambient temperatures or rapid temperature changes.
Classified as CS, this detector is commonly used in areas such as boiler rooms, plant rooms and industrial spaces where higher background temperatures are expected. It responds only when the fixed temperature threshold is reached, helping to minimise nuisance alarms in demanding conditions.
Part of the Apollo AlarmSense range, the detector connects to a two-wire conventional system, allowing detectors, sounders and call points to be installed on a single cable pair. This reduces installation time and simplifies system design.
This set includes the Apollo 45681-244APO AlarmSense detector base.
Apollo 55000-193APO
Apollo 45681-244APO AlarmSense Detector Base
High Temperature Heat Detector
Can be used for applications where smoke detectors are unsuitable
Ideal environments that are dirty or smoky under normal conditions
CS detectors are ideal for use in environments with rapid temperature fluctuations such as boiler rooms
360 visibility of LEDs
Reduction of false alarms
Quick and simple installation
compatible with any Apollo Alarmsense fire alarm panel
Specification | Value |
|---|---|
Detection principle | Heat sensitive resistance using a single NTC thermistor |
Sampling frequency | Once every four seconds |
Supply voltage | 9 Vdc to 33 Vdc |
Supply wiring | Two wire supply, polarity insensitive |
Quiescent current at 15 V | < 50 µA |
Alarm current (2–8.5 V) | < 1.5 mA |
Alarm current (10.5–15 V) | 25 ± 2 mA |
Alarm current (18–24 V) | < 1.5 mA |
Alarm current (33 V) | < 2 mA |
Maximum reset voltage | 2 V |
Reset time | 1 second |
Maximum supply interruption time | 40 ms |
Operating temperature (A1R) | -40°C to +50°C |
Operating temperature (CS) | -40°C to +80°C |
Humidity | 0% to 95% RH (no condensation or icing) |
IP Rating | Designed to IP44 |
Standards and approvals | EN 54-5, CPR and FG |
Dimensions | 100 mm diameter × 42 mm height |
Dimensions in base | 100 mm diameter × 50 mm height |
Weight | 80 g (detector) |
Materials – Housing | White flame-retardant polycarbonate |
Materials – Terminals | Nickel plated stainless steel |
The Apollo 55000-193APO AlarmSense CS High Temperature Heat Detector is a static heat detector designed to operate at a fixed temperature of 90°C. It is suited to environments where standard heat or smoke detection may not be appropriate due to high ambient temperatures or rapid temperature changes.
Classified as CS, this detector is commonly used in areas such as boiler rooms, plant rooms and industrial spaces where higher background temperatures are expected. It responds only when the fixed temperature threshold is reached, helping to minimise nuisance alarms in demanding conditions.
Part of the Apollo AlarmSense range, the detector connects to a two-wire conventional system, allowing detectors, sounders and call points to be installed on a single cable pair. This reduces installation time and simplifies system design.
This set includes the Apollo 45681-244APO AlarmSense detector base.
Apollo 55000-193APO
Apollo 45681-244APO AlarmSense Detector Base
High Temperature Heat Detector
Can be used for applications where smoke detectors are unsuitable
Ideal environments that are dirty or smoky under normal conditions
CS detectors are ideal for use in environments with rapid temperature fluctuations such as boiler rooms
360 visibility of LEDs
Reduction of false alarms
Quick and simple installation
compatible with any Apollo Alarmsense fire alarm panel
Specification | Value |
|---|---|
Detection principle | Heat sensitive resistance using a single NTC thermistor |
Sampling frequency | Once every four seconds |
Supply voltage | 9 Vdc to 33 Vdc |
Supply wiring | Two wire supply, polarity insensitive |
Quiescent current at 15 V | < 50 µA |
Alarm current (2–8.5 V) | < 1.5 mA |
Alarm current (10.5–15 V) | 25 ± 2 mA |
Alarm current (18–24 V) | < 1.5 mA |
Alarm current (33 V) | < 2 mA |
Maximum reset voltage | 2 V |
Reset time | 1 second |
Maximum supply interruption time | 40 ms |
Operating temperature (A1R) | -40°C to +50°C |
Operating temperature (CS) | -40°C to +80°C |
Humidity | 0% to 95% RH (no condensation or icing) |
IP Rating | Designed to IP44 |
Standards and approvals | EN 54-5, CPR and FG |
Dimensions | 100 mm diameter × 42 mm height |
Dimensions in base | 100 mm diameter × 50 mm height |
Weight | 80 g (detector) |
Materials – Housing | White flame-retardant polycarbonate |
Materials – Terminals | Nickel plated stainless steel |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.