Book your manufacturer training with Fire Detection Shop today
Product | Price (ex VAT) | Quantity | Total (ex VAT) |
---|---|---|---|
|
£
ex VAT
|
£0.00
|
Code: FDS600/013
INC VAT
Code: FDS600/013
The Apollo 55100-908APO XP95 Addressable Manual Call Point is a legacy model designed for use with addressable fire alarm systems that operate on the Apollo XP95 protocol.
Compatible with Apollo XP95 addressable systems
Legacy style manual call point – available by order only
Address set via DIL switch for commissioning flexibility
Resettable element for reduced maintenance
Plug-and-play terminals for fast installation
Ideal for system expansions or replacements, this call point features a seven-segment DIL switch for address configuration during commissioning, providing flexibility and straightforward setup.
Installation is quick thanks to plug-and-play terminal connections, while the resettable element helps reduce maintenance time and long-term servicing costs.
Please note: This is an older style unit and is available to order only.
Apollo 55100-908APO
Matches existing call points
Plug and play terminal connections for fast wiring
Easy wiring continuity testing before fitting
Resettable element
Built in isolator
Reports an alarm in under 0.2 seconds
Warranty | 10 year |
Colour | Red |
Weight | 151g |
Materials housing | Polycarbonate, ABS |
Product length | 93mm |
Product width | 89mm |
Product depth | 26.5mm |
Detection principle | Operation of a switch |
Product length (inches) | 3.66in |
Product width (inches) | 3.5in |
Product depth (inches) | 1.04in |
Standards | EN 54-17 |
Approvals | LPCB, CPR |
Protocol voltage (max) | 9V |
Protocol voltage (min) | 5V |
Protocol voltage | 5 to 9V peak to peak |
Power-up surge current | 1mA |
Maximum power-up time | 1 second |
Quiescent current | 100μA |
Quiescent current tested at | 24V dc |
Humidity (max) | 95% RH |
Humidity (min) | 0% RH |
Humidity | 0% to 95% (no condensation or icing) |
Humidity Note | no condensation or icing |
Operating temperature | -20 to 60°C |
Operating temperature (max) | 60°C |
Operating temperature (min) | -20°C |
IP rating Value | IP24 |
Storage temperature (min) | -30°C |
Storage temperature (max) | 80°C |
Storage temperature | -30 to 80°C |
Operating Temperature (°F) | -4 to 140°F |
Operating temperature (max) | 140°F |
Operating temperature (min) | -4°F |
Part Number | 55100-908APO |
The Apollo 55100-908APO XP95 Addressable Manual Call Point is a legacy model designed for use with addressable fire alarm systems that operate on the Apollo XP95 protocol.
Compatible with Apollo XP95 addressable systems
Legacy style manual call point – available by order only
Address set via DIL switch for commissioning flexibility
Resettable element for reduced maintenance
Plug-and-play terminals for fast installation
Ideal for system expansions or replacements, this call point features a seven-segment DIL switch for address configuration during commissioning, providing flexibility and straightforward setup.
Installation is quick thanks to plug-and-play terminal connections, while the resettable element helps reduce maintenance time and long-term servicing costs.
Please note: This is an older style unit and is available to order only.
Apollo 55100-908APO
Matches existing call points
Plug and play terminal connections for fast wiring
Easy wiring continuity testing before fitting
Resettable element
Built in isolator
Reports an alarm in under 0.2 seconds
Warranty | 10 year |
Colour | Red |
Weight | 151g |
Materials housing | Polycarbonate, ABS |
Product length | 93mm |
Product width | 89mm |
Product depth | 26.5mm |
Detection principle | Operation of a switch |
Product length (inches) | 3.66in |
Product width (inches) | 3.5in |
Product depth (inches) | 1.04in |
Standards | EN 54-17 |
Approvals | LPCB, CPR |
Protocol voltage (max) | 9V |
Protocol voltage (min) | 5V |
Protocol voltage | 5 to 9V peak to peak |
Power-up surge current | 1mA |
Maximum power-up time | 1 second |
Quiescent current | 100μA |
Quiescent current tested at | 24V dc |
Humidity (max) | 95% RH |
Humidity (min) | 0% RH |
Humidity | 0% to 95% (no condensation or icing) |
Humidity Note | no condensation or icing |
Operating temperature | -20 to 60°C |
Operating temperature (max) | 60°C |
Operating temperature (min) | -20°C |
IP rating Value | IP24 |
Storage temperature (min) | -30°C |
Storage temperature (max) | 80°C |
Storage temperature | -30 to 80°C |
Operating Temperature (°F) | -4 to 140°F |
Operating temperature (max) | 140°F |
Operating temperature (min) | -4°F |
Part Number | 55100-908APO |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.