The Apollo 55100-905APO is a legacy-style addressable manual call point designed for use with fire alarm systems operating on the Apollo XP95 protocol.
This model is ideal for maintaining visual consistency in systems with older call points already installed.
Each unit is addressed manually using a 7-segment DIL switch during commissioning. It features plug-and-play terminal connections for efficient wiring and a resettable element, allowing the device to be reused after activation without the need to replace any parts. Wiring continuity can also be easily verified before final installation.
This is a non-isolator model, and is suitable for systems where isolation is handled separately or not required. It reports an alarm condition in under 0.2 seconds, ensuring rapid notification in the event of an emergency.
Apollo 55100-908APO
Matches existing call points
Plug and play terminal connections for fast wiring
Easy wiring continuity testing before fitting
Resettable element
Non isolator model
Reports an alarm in under 0.2 seconds
Warranty | 10 year |
Colour | Red |
Weight | 151g |
Materials housing | Polycarbonate, ABS |
Product length | 93mm |
Product width | 89mm |
Product depth | 26.5mm |
Detection principle | Operation of a switch |
Product length (inches) | 3.66in |
Product width (inches) | 3.5in |
Product depth (inches) | 1.04in |
Standards | EN 54-11 |
Approvals | CCCf, LPCB, CPR |
Protocol voltage (max) | 9V |
Protocol voltage (min) | 5V |
Protocol voltage | 5 to 9V peak to peak |
Power-up surge current | 1mA |
Maximum power-up time | 1 second |
Quiescent current | 100μA |
Quiescent current tested at | 24V dc |
Humidity (max) | 95% RH |
Humidity (min) | 0% RH |
Humidity | 0% to 95% (no condensation or icing) |
Humidity Note | no condensation or icing |
Operating temperature | -20 to 60°C |
Operating temperature (max) | 60°C |
Operating temperature (min) | -20°C |
IP rating Value | IP24 |
Storage temperature (min) | -30°C |
Storage temperature (max) | 80°C |
Storage temperature | -30 to 80°C |
Operating Temperature (°F) | -4 to 140°F |
Operating temperature (max) | 140°F |
Operating temperature (min) | -4°F |
Part Number | 55100-908APO |
No, the 55100-905APO is a non-isolator version. If loop isolation is required, consider using the Apollo 55100-908APO instead.
The address is configured using a seven-segment DIL switch, typically at the commissioning stage.
While it is technically compatible, this model is more suitable for refurbishment or extension projects where matching older equipment is essential. For new installations, Apollo’s updated call point models may be more appropriate.
The Apollo 55100-905APO is a legacy-style addressable manual call point designed for use with fire alarm systems operating on the Apollo XP95 protocol.
This model is ideal for maintaining visual consistency in systems with older call points already installed.
Each unit is addressed manually using a 7-segment DIL switch during commissioning. It features plug-and-play terminal connections for efficient wiring and a resettable element, allowing the device to be reused after activation without the need to replace any parts. Wiring continuity can also be easily verified before final installation.
This is a non-isolator model, and is suitable for systems where isolation is handled separately or not required. It reports an alarm condition in under 0.2 seconds, ensuring rapid notification in the event of an emergency.
Apollo 55100-908APO
Matches existing call points
Plug and play terminal connections for fast wiring
Easy wiring continuity testing before fitting
Resettable element
Non isolator model
Reports an alarm in under 0.2 seconds
Warranty | 10 year |
Colour | Red |
Weight | 151g |
Materials housing | Polycarbonate, ABS |
Product length | 93mm |
Product width | 89mm |
Product depth | 26.5mm |
Detection principle | Operation of a switch |
Product length (inches) | 3.66in |
Product width (inches) | 3.5in |
Product depth (inches) | 1.04in |
Standards | EN 54-11 |
Approvals | CCCf, LPCB, CPR |
Protocol voltage (max) | 9V |
Protocol voltage (min) | 5V |
Protocol voltage | 5 to 9V peak to peak |
Power-up surge current | 1mA |
Maximum power-up time | 1 second |
Quiescent current | 100μA |
Quiescent current tested at | 24V dc |
Humidity (max) | 95% RH |
Humidity (min) | 0% RH |
Humidity | 0% to 95% (no condensation or icing) |
Humidity Note | no condensation or icing |
Operating temperature | -20 to 60°C |
Operating temperature (max) | 60°C |
Operating temperature (min) | -20°C |
IP rating Value | IP24 |
Storage temperature (min) | -30°C |
Storage temperature (max) | 80°C |
Storage temperature | -30 to 80°C |
Operating Temperature (°F) | -4 to 140°F |
Operating temperature (max) | 140°F |
Operating temperature (min) | -4°F |
Part Number | 55100-908APO |
No, the 55100-905APO is a non-isolator version. If loop isolation is required, consider using the Apollo 55100-908APO instead.
The address is configured using a seven-segment DIL switch, typically at the commissioning stage.
While it is technically compatible, this model is more suitable for refurbishment or extension projects where matching older equipment is essential. For new installations, Apollo’s updated call point models may be more appropriate.
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.