The Apollo 55000-122APO Series 65 A1R Heat Detector is a reliable conventional detector suitable for use with most conventional fire alarm control panels.
Housed in a casing that matches other detectors in the Apollo Series 65 range, it ensures visual consistency across your system.
This A1R model uses a dual thermistor sensing network to monitor ambient temperature. It is designed to trigger an alarm when the temperature rises rapidly—between 12°C and 15°C per minute, or reaches a fixed threshold of 57°C.
This makes it ideal for areas where smoke detectors may cause false alarms, such as kitchens, boiler rooms, or garages.
Apollo 55000-122APO
Can be used for applications where smoke detectors are unsuitable
Ideal for environments that are dirty or smoky under natural conditions
Wide operating voltage
Flashing LED and magnet operated test switch option
Complete with diode base
Warranty | 10 years |
Applications | B&Bs/guest houses Cafes Dusty environments Restaurants Retail Small to medium buildings |
Heat classification | A1R |
Colour | White |
Weight | 80g |
Materials housing | Polycarbonate |
Product length | 42mm |
Product diameter | 100mm |
Product length | 1.65in |
Product diameter | 3.94in |
Standards | EN 54-5 |
Approvals | CPR FG VdS BOSEC LPCB |
Polarity | L1 & L2 are polarity insensitive |
Holding voltage | 6 to 6V |
Holding voltage (max) | 6V |
Holding voltage (min) | 6V |
Minimum voltage to light alarm LED | 12V |
Alarm load | 420Ω in series with 2V drop |
Humidity (max) | 95% RH |
Humidity (min) | 0% RH |
Humidity Note | no condensation or icing |
Humidity | 0% to 95% (no condensation or icing) |
Operating temperature | -20 to 90°C |
Operating temperature (max) | 90°C |
Operating temperature (min) | -20°C |
IP rating Value | IP23D |
Storage temperature (max) |
|
Storage temperature (min) | -30°C |
It is compatible with most conventional fire alarm control panels.
A1R heat detectors are ideal for environments where smoke may be present during normal conditions, such as commercial kitchens, utility rooms, or workshops.
The detector triggers an alarm either when the temperature exceeds 57°C or when there is a rapid temperature increase of 12–15°C per minute.
The Apollo 55000-122APO Series 65 A1R Heat Detector is a reliable conventional detector suitable for use with most conventional fire alarm control panels.
Housed in a casing that matches other detectors in the Apollo Series 65 range, it ensures visual consistency across your system.
This A1R model uses a dual thermistor sensing network to monitor ambient temperature. It is designed to trigger an alarm when the temperature rises rapidly—between 12°C and 15°C per minute, or reaches a fixed threshold of 57°C.
This makes it ideal for areas where smoke detectors may cause false alarms, such as kitchens, boiler rooms, or garages.
Apollo 55000-122APO
Can be used for applications where smoke detectors are unsuitable
Ideal for environments that are dirty or smoky under natural conditions
Wide operating voltage
Flashing LED and magnet operated test switch option
Complete with diode base
Warranty | 10 years |
Applications | B&Bs/guest houses Cafes Dusty environments Restaurants Retail Small to medium buildings |
Heat classification | A1R |
Colour | White |
Weight | 80g |
Materials housing | Polycarbonate |
Product length | 42mm |
Product diameter | 100mm |
Product length | 1.65in |
Product diameter | 3.94in |
Standards | EN 54-5 |
Approvals | CPR FG VdS BOSEC LPCB |
Polarity | L1 & L2 are polarity insensitive |
Holding voltage | 6 to 6V |
Holding voltage (max) | 6V |
Holding voltage (min) | 6V |
Minimum voltage to light alarm LED | 12V |
Alarm load | 420Ω in series with 2V drop |
Humidity (max) | 95% RH |
Humidity (min) | 0% RH |
Humidity Note | no condensation or icing |
Humidity | 0% to 95% (no condensation or icing) |
Operating temperature | -20 to 90°C |
Operating temperature (max) | 90°C |
Operating temperature (min) | -20°C |
IP rating Value | IP23D |
Storage temperature (max) |
|
Storage temperature (min) | -30°C |
It is compatible with most conventional fire alarm control panels.
A1R heat detectors are ideal for environments where smoke may be present during normal conditions, such as commercial kitchens, utility rooms, or workshops.
The detector triggers an alarm either when the temperature exceeds 57°C or when there is a rapid temperature increase of 12–15°C per minute.
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.