The Apollo 55000-137APO Series 65 CS Heat Detector is a conventional fixed temperature heat detector supplied with a diode base, making it suitable for systems where manual call points and detector bases are wired on the same circuit.
It monitors ambient temperature using a dual thermistor network and signals the control panel when the alarm threshold is reached. The CS detector has a fixed upper temperature limit of 90°C, which makes it a practical option for higher ambient temperature areas where smoke detection is unsuitable.
This model is commonly used in locations that are dusty, steamy or subject to fumes under normal conditions, such as kitchens, plant rooms, workshops and some industrial areas, helping to reduce nuisance alarms compared with smoke detection.
Designed for use with most conventional fire alarm panels, it fits Apollo Series 65 bases and is a straightforward choice when standardising on Series 65 devices across a conventional system.
Apollo 55000-137APO
Can be used for applications where smoke detectors are unsuitable, ideal for environments that are dirty or smoky under natural conditions
Wide operating voltage
Flashing LED and magnet operated test switch option
Base supplied separately (please see related products below)
Specification | Value |
|---|---|
Warranty | 10 year |
Applications | B&Bs/guest houses, Cafes, Dusty environments, Restaurants, Retail, Small to medium buildings |
Classification | CS |
Chamber type | Chevron |
Colour | White |
Weight | 80g |
Housing material | Polycarbonate |
Terminal material | Nickel plated stainless steel |
Dimensions | 42mm (L), 100mm (Dia) |
Dimensions | 1.65in (L), 3.94in (Dia) |
Approvals | BOSEC, FG, VdS, LPCB, CPR |
Quiescent current | 250μA |
Polarity | L1 & L2 are polarity insensitive |
Holding voltage | 6V (min/max) |
LED alarm voltage | 12V minimum |
Alarm load | 420Ω in series with 2V drop |
Humidity | 0% to 95% RH (no condensation or icing) |
Temperature | -20 to 90°C (operating), -30 to 120°C (storage) |
Temperature | -4 to 194°F (operating) |
IP rating | IP23D |
The Apollo 55000-137APO Series 65 CS Heat Detector is a conventional fixed temperature heat detector supplied with a diode base, making it suitable for systems where manual call points and detector bases are wired on the same circuit.
It monitors ambient temperature using a dual thermistor network and signals the control panel when the alarm threshold is reached. The CS detector has a fixed upper temperature limit of 90°C, which makes it a practical option for higher ambient temperature areas where smoke detection is unsuitable.
This model is commonly used in locations that are dusty, steamy or subject to fumes under normal conditions, such as kitchens, plant rooms, workshops and some industrial areas, helping to reduce nuisance alarms compared with smoke detection.
Designed for use with most conventional fire alarm panels, it fits Apollo Series 65 bases and is a straightforward choice when standardising on Series 65 devices across a conventional system.
Apollo 55000-137APO
Can be used for applications where smoke detectors are unsuitable, ideal for environments that are dirty or smoky under natural conditions
Wide operating voltage
Flashing LED and magnet operated test switch option
Base supplied separately (please see related products below)
Specification | Value |
|---|---|
Warranty | 10 year |
Applications | B&Bs/guest houses, Cafes, Dusty environments, Restaurants, Retail, Small to medium buildings |
Classification | CS |
Chamber type | Chevron |
Colour | White |
Weight | 80g |
Housing material | Polycarbonate |
Terminal material | Nickel plated stainless steel |
Dimensions | 42mm (L), 100mm (Dia) |
Dimensions | 1.65in (L), 3.94in (Dia) |
Approvals | BOSEC, FG, VdS, LPCB, CPR |
Quiescent current | 250μA |
Polarity | L1 & L2 are polarity insensitive |
Holding voltage | 6V (min/max) |
LED alarm voltage | 12V minimum |
Alarm load | 420Ω in series with 2V drop |
Humidity | 0% to 95% RH (no condensation or icing) |
Temperature | -20 to 90°C (operating), -30 to 120°C (storage) |
Temperature | -4 to 194°F (operating) |
IP rating | IP23D |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.