The Hochiki YBO-R/6R Conventional Relay Base is a reliable detector mounting base designed for use with the Hochiki CDX Range of Detectors, offering dependable performance in conventional fire detection and security systems. With a wide operating voltage range, the base is suitable for integration with most conventional fire alarm and security control panels, providing flexibility across a range of installations.
Engineered for straightforward installation and long-term durability, the YBO-R/6R features square cable clamps that provide quick, secure cable termination and support cables up to 2.5 mm in size. The base incorporates a bayonet slot design with low insertion force, allowing detectors to be fitted or removed quickly, helping reduce installation and maintenance time.
An integral remote indicator output is provided through a dedicated third terminal, enabling the connection of an external indicator for situations where detectors are installed in concealed or hard-to-view locations.
The base features a rugged construction designed for dependable operation in demanding environments. As the base does not maintain line continuity when the detector is removed, manual call points should be connected at the beginning of the zone when used within the same circuit.
Finished in ivory, the YBO-R/6R blends easily into most commercial and residential environments while delivering reliable functionality as part of a conventional detection system. The unit also has LPCB approval, confirming compliance with recognised fire safety standards.
Integral remote indicator output
Wide voltage range - can be used in security systems
Rugged design
Quick connections via square cable clamps
Accepts 2.5 mm cables
Bayonet slot, low insertion force for detectors
Approved by LPCB
Ordering Code | YBO-R/6R |
Operating Voltage | 9.5 – 30 V dc |
Relay Voltage | 30 V dc @ 1 A (non-inductive) |
Operating Temperature Range | -10 °C to + 50 °C |
Storage Temperature Range | -30 °C to + 60 °C |
Maximum Humidity | 95%RH - Non Condensing (at 40 °C) |
Colour / Material | Ivory White / ABS |
Weight (g) / Diameter (mm) / Height (mm) | 87 / 100 / 13 |
Fixing Centres (mm) | 48 ~ 74 |
Maximum Wire Thickness | 2.5 mm² Cables |
The Hochiki YBO-R/6R Conventional Relay Base is a reliable detector mounting base designed for use with the Hochiki CDX Range of Detectors, offering dependable performance in conventional fire detection and security systems. With a wide operating voltage range, the base is suitable for integration with most conventional fire alarm and security control panels, providing flexibility across a range of installations.
Engineered for straightforward installation and long-term durability, the YBO-R/6R features square cable clamps that provide quick, secure cable termination and support cables up to 2.5 mm in size. The base incorporates a bayonet slot design with low insertion force, allowing detectors to be fitted or removed quickly, helping reduce installation and maintenance time.
An integral remote indicator output is provided through a dedicated third terminal, enabling the connection of an external indicator for situations where detectors are installed in concealed or hard-to-view locations.
The base features a rugged construction designed for dependable operation in demanding environments. As the base does not maintain line continuity when the detector is removed, manual call points should be connected at the beginning of the zone when used within the same circuit.
Finished in ivory, the YBO-R/6R blends easily into most commercial and residential environments while delivering reliable functionality as part of a conventional detection system. The unit also has LPCB approval, confirming compliance with recognised fire safety standards.
Integral remote indicator output
Wide voltage range - can be used in security systems
Rugged design
Quick connections via square cable clamps
Accepts 2.5 mm cables
Bayonet slot, low insertion force for detectors
Approved by LPCB
Ordering Code | YBO-R/6R |
Operating Voltage | 9.5 – 30 V dc |
Relay Voltage | 30 V dc @ 1 A (non-inductive) |
Operating Temperature Range | -10 °C to + 50 °C |
Storage Temperature Range | -30 °C to + 60 °C |
Maximum Humidity | 95%RH - Non Condensing (at 40 °C) |
Colour / Material | Ivory White / ABS |
Weight (g) / Diameter (mm) / Height (mm) | 87 / 100 / 13 |
Fixing Centres (mm) | 48 ~ 74 |
Maximum Wire Thickness | 2.5 mm² Cables |
FDS330/900
FDS330/901
FDS330/902
FDS331/283
FDS340/041
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.