Provide us with a few simple details, and our in-house engineers can produce your zone plan chart.
| Product | Price (ex VAT) | Quantity | Total (ex VAT) |
|---|---|---|---|
|
|
£
ex VAT
|
£0.00
|
1 item added to basket
4 Zone Fire Alarm Conventional Kit - Hospitality Sector
We Recommend
Bestseller
Code: FDS330/901
INC VAT
Code: FDS330/901
The 4 Zone Conventional Fire Alarm Kit – Hospitality Sector is designed specifically for cafés, restaurants, bars and similar hospitality environments that require a reliable and easy to install fire detection system.
Kit Contents
1 × C-TEC CFP704-4 4 Zone Conventional Fire Alarm Panel
4 × FireSmart Optical Smoke Detectors
1 × FireSmart Rate-of-Rise Heat Detector
2 × FireSmart Universal Conventional Manual Call Points
2 × FireSmart Sounders with Bases
2 × FireSmart Beacons with Bases
2 × FireSmart 12Vdc 3.2Ah Backup Batteries
This complete kit provides all the essential components needed to begin installation quickly, combining the trusted C-TEC CFP704-4 conventional fire alarm panel with reliable FireSmart detection and alarm devices. The fully compatible components ensure straightforward installation while delivering dependable system performance.
The kit includes optical smoke detectors for general detection areas, a rate-of-rise heat detector for kitchens or areas where smoke detection may not be suitable, manual call points for manual activation and sounders with beacons to provide clear audible and visual alarm notification.
Ideal for small to medium sized hospitality venues and public buildings, this kit offers a practical and cost-effective fire protection solution.
C-TEC CFP704-4 2 Zone Conventional Fire Alarm Panel: The C-TEC CFP704-4 2 zone conventional fire alarm panel is LPCB certified to the latest revisions of EN54 parts 2 and 4, offers an array of user and installer-friendly features at a very competitive price.
FireSmart Optical Smoke Detectors: A state of the art optical chamber combined with an application specific integrated circuit (ASIC) to provide quick and accurate detection of fires.
FireSmart Rate-of-Rise Heat Detector: The Heat Detector uses a state of the art heat element combined with an application specific integrated circuit (ASIC) to provide quick and accurate detection of fires.
FireSmart Diode Bases: Diode base for use with the FireSmart range of detectors.
FireSmart Conventional Manual Call Points: An easy to operate fire alarm manual call point. Fully compliant with EN 54-11, each point is manufactured from impact resistant ABS and include a resettable press to break glass.
FireSmart Sounder & Deep Bases (Red): Provides outstanding sound output and low current draw. Specifically designed and approved to meet EN54-3 the FireSmart sounder delivers quality, reliability and extended operational life.
FireSmart Conventional VID Deep Base w/ Red Flash: Features high output LEDs, advanced optics and an innovative lens design. Approved to meet EN54-23.
FireSmart 12vdc 3.2Ah Backup Batteries: 12v 2.2Ah batteries specifically designed for use throughout the fire and security industries.
Specification | 4 Zone Panel |
|---|---|
Approvals/Certifications | EN54 Parts 2 & 4 (LPCB), EN54-13 (Kiwa Telefication) |
Mains Supply | 230V 50/60Hz |
Mains Rated Current | 350mA max |
Internal Power Supply | 19V–28.5V (27V nominal), Ripple 7V max |
Total Output Current | 1.5A @ 230Vac (ImaxA eq 146mA) |
Quiescent Current | 25mA (mains failed, internal sounder active) |
Max Battery Size & Type | 2 x 12V 3.2Ah VRLA (Min. 1.2Ah) |
No. of Detector Zones | 4 (Max. 500m per circuit) |
Call Point Resistor Value | 470 to 680Ω |
Max Devices per Zone | Same |
No. of Sounder Circuits | 4 (Max. 500m per circuit) |
EOL Resistor Value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Alarm Voltage | 27V max, 20V min |
Max Sounder Output Current | 4 x 200mA (800mA total) |
Auxiliary Relays | 2: Aux. Fire & Fault, volt-free SPCO, 1A @ 30Vdc |
Open Collector Outputs | 2: Reset & Remote, 30mA max sink, 30V open circuit |
Other Outputs | 24V Aux Power, resettable fuse, 100mA min hold |
Auxiliary Inputs | 2: Class Change & Alert, 27V max input |
Engineer Functions | Coincidence, 1-man test, programmable delays, zone & sounder behaviour settings |
Expansion Connections | Yes – repeater/network/relay/sounder interface board compatible |
Product Dimensions (mm) | 380 W x 235 H x 96 D (Flush: 367 W x 220 H x 75 D) |
Construction & Finish | Plastic lid/base, RAL7035 textured |
IP Rating | IP30 |
Weight | 1.75kg (without batteries) |
Operating Conditions | -5ºC to +40ºC, 95% RH max |
The 4 Zone Conventional Fire Alarm Kit – Hospitality Sector is designed specifically for cafés, restaurants, bars and similar hospitality environments that require a reliable and easy to install fire detection system.
Kit Contents
1 × C-TEC CFP704-4 4 Zone Conventional Fire Alarm Panel
4 × FireSmart Optical Smoke Detectors
1 × FireSmart Rate-of-Rise Heat Detector
2 × FireSmart Universal Conventional Manual Call Points
2 × FireSmart Sounders with Bases
2 × FireSmart Beacons with Bases
2 × FireSmart 12Vdc 3.2Ah Backup Batteries
This complete kit provides all the essential components needed to begin installation quickly, combining the trusted C-TEC CFP704-4 conventional fire alarm panel with reliable FireSmart detection and alarm devices. The fully compatible components ensure straightforward installation while delivering dependable system performance.
The kit includes optical smoke detectors for general detection areas, a rate-of-rise heat detector for kitchens or areas where smoke detection may not be suitable, manual call points for manual activation and sounders with beacons to provide clear audible and visual alarm notification.
Ideal for small to medium sized hospitality venues and public buildings, this kit offers a practical and cost-effective fire protection solution.
C-TEC CFP704-4 2 Zone Conventional Fire Alarm Panel: The C-TEC CFP704-4 2 zone conventional fire alarm panel is LPCB certified to the latest revisions of EN54 parts 2 and 4, offers an array of user and installer-friendly features at a very competitive price.
FireSmart Optical Smoke Detectors: A state of the art optical chamber combined with an application specific integrated circuit (ASIC) to provide quick and accurate detection of fires.
FireSmart Rate-of-Rise Heat Detector: The Heat Detector uses a state of the art heat element combined with an application specific integrated circuit (ASIC) to provide quick and accurate detection of fires.
FireSmart Diode Bases: Diode base for use with the FireSmart range of detectors.
FireSmart Conventional Manual Call Points: An easy to operate fire alarm manual call point. Fully compliant with EN 54-11, each point is manufactured from impact resistant ABS and include a resettable press to break glass.
FireSmart Sounder & Deep Bases (Red): Provides outstanding sound output and low current draw. Specifically designed and approved to meet EN54-3 the FireSmart sounder delivers quality, reliability and extended operational life.
FireSmart Conventional VID Deep Base w/ Red Flash: Features high output LEDs, advanced optics and an innovative lens design. Approved to meet EN54-23.
FireSmart 12vdc 3.2Ah Backup Batteries: 12v 2.2Ah batteries specifically designed for use throughout the fire and security industries.
Specification | 4 Zone Panel |
|---|---|
Approvals/Certifications | EN54 Parts 2 & 4 (LPCB), EN54-13 (Kiwa Telefication) |
Mains Supply | 230V 50/60Hz |
Mains Rated Current | 350mA max |
Internal Power Supply | 19V–28.5V (27V nominal), Ripple 7V max |
Total Output Current | 1.5A @ 230Vac (ImaxA eq 146mA) |
Quiescent Current | 25mA (mains failed, internal sounder active) |
Max Battery Size & Type | 2 x 12V 3.2Ah VRLA (Min. 1.2Ah) |
No. of Detector Zones | 4 (Max. 500m per circuit) |
Call Point Resistor Value | 470 to 680Ω |
Max Devices per Zone | Same |
No. of Sounder Circuits | 4 (Max. 500m per circuit) |
EOL Resistor Value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Alarm Voltage | 27V max, 20V min |
Max Sounder Output Current | 4 x 200mA (800mA total) |
Auxiliary Relays | 2: Aux. Fire & Fault, volt-free SPCO, 1A @ 30Vdc |
Open Collector Outputs | 2: Reset & Remote, 30mA max sink, 30V open circuit |
Other Outputs | 24V Aux Power, resettable fuse, 100mA min hold |
Auxiliary Inputs | 2: Class Change & Alert, 27V max input |
Engineer Functions | Coincidence, 1-man test, programmable delays, zone & sounder behaviour settings |
Expansion Connections | Yes – repeater/network/relay/sounder interface board compatible |
Product Dimensions (mm) | 380 W x 235 H x 96 D (Flush: 367 W x 220 H x 75 D) |
Construction & Finish | Plastic lid/base, RAL7035 textured |
IP Rating | IP30 |
Weight | 1.75kg (without batteries) |
Operating Conditions | -5ºC to +40ºC, 95% RH max |
FDS330/900
FDS330/902
FDS331/283
FDS340/041
FDS361/015
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.