Provide us with a few simple details, and our in-house engineers can produce your zone plan chart.
| Product | Price (ex VAT) | Quantity | Total (ex VAT) |
|---|---|---|---|
|
|
£
ex VAT
|
£0.00
|
1 item added to basket
C-TEC LAP501/CA CAST Addressable 1 Loop 32 Zone Lockdown Alert Panel
Code: FDS005/011
£565.44
INC VAT
Code: FDS005/011
The C-TEC LAP501/CA is a dedicated CAST addressable single-message lockdown and invacuation control panel designed for smaller, straightforward applications. Fully monitored and battery backed, it provides a central control point for a C-TEC CAST lockdown system and is designed for use with compatible CAST lockdown voice sounders, sounder VADs and lockdown call points.
When a CAST lockdown call point is activated, the panel broadcasts a full lockdown voice message through connected CAST lockdown voice sounders or sounder VADs, helping communicate that an immediate threat is present within the building. The system supports up to 255 addressable devices on its single loop, with a maximum loop length of 1km and loop output current of 450mA.
The LAP501/CA is ENVISION Enabled and compatible with C-TEC's cloud-based data management software, allowing incidents to be monitored either on or off site. It also provides two conventional sounder circuits, programmable auxiliary inputs and relays, a 24V auxiliary power output and comprehensive status indication via a two-line backlit display and 32 zonal LEDs.
The panel has been designed to help smaller venues prepare for the Terrorism (Protection of Premises) Act 2025, commonly known as Martyn's Law, which introduces public protection requirements including lockdown planning for certain premises and events.
Powered from a 230V AC mains supply, the panel supports two 12V 7Ah VRLA batteries connected in series for standby operation.
LAP501/CA
Dedicated single-message CAST lockdown and invacuation control panel
Broadcasts a full lockdown voice message when a CAST lockdown call point is activated
Fully monitored and battery backed
Single addressable loop supporting up to 255 devices
Maximum loop length of 1km
ENVISION Enabled for cloud-based incident monitoring
Two conventional sounder circuits
32 zonal LED indicators and two-line backlit display
Programmable auxiliary inputs and relay outputs
Specification | Details |
|---|---|
Model | LAP501/CA |
Protocol | C-TEC CAST |
Mains Supply | 230V 50/60Hz |
Mains Rated Current | 680mA maximum |
Internal Power Supply | 27Vdc nominal |
Total Output Current | Limited to 3A @ 230Vac (Imax.A 250mA; Imin. 70mA) |
Quiescent Current | 80mA (loop unloaded) |
Maximum Battery Size And Type | 2 x 12V 7Ah VRLA connected in series |
Number Of Loop Drivers | 1 |
Maximum Loop Output Current | 450mA (40V max) |
Maximum Loop Length | 1km |
Maximum Addressable Devices Per Loop | 255 |
Conventional Sounder Circuits | 2, maximum length per circuit 500m |
EOL Resistor Value | 6800Ω 5% Tol. 0.25W (blue, grey, red, gold) |
Maximum Sounder Output Current | 400mA |
Auxiliary Relays | 3 x programmable relays, 1 x fault relay, volt-free single pole changeover, max. switch current 1A, max. switch voltage 30Vdc |
Other Outputs | 24V Aux. Power, 19.5V min., 28V max., protected by resettable fuse, max. current 100mA |
Auxiliary Inputs | 2 x programmable inputs, connect to 0V to trigger, max. input voltage 27V, non-latching |
PC Connection | RS232 Molex connector, supplied in XFP507 upload/download software kit; no printer connection available |
Indicators | 2 line x 40 character backlit display; 32 zonal LEDs; General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault |
Connections | Fixed, largest acceptable conductor size 1mm² |
Expansion Connections | 2-wire RS485 non-redundant network/repeater connection via optional AFP711 network card |
Maximum Network Capacity | 8 mains per network, limit 1km, or 8 repeaters per non-networked main |
Base Dimensions | 410 W x 250 H x 80 D mm |
Lid Dimensions | 439 W x 274 H x 7 D mm |
Semi-Flush Mounting Hole | 412 W x 255 H x 50 D mm, requires XFP385 bezel |
Construction | Metal |
IP Rating | IP30 |
Weight | 4.5kg, no batteries |
Operating Temperature | -5ºC to +40ºC |
Maximum Relative Humidity | 95% |
The C-TEC LAP501/CA is a dedicated CAST addressable single-message lockdown and invacuation control panel designed for smaller, straightforward applications. Fully monitored and battery backed, it provides a central control point for a C-TEC CAST lockdown system and is designed for use with compatible CAST lockdown voice sounders, sounder VADs and lockdown call points.
When a CAST lockdown call point is activated, the panel broadcasts a full lockdown voice message through connected CAST lockdown voice sounders or sounder VADs, helping communicate that an immediate threat is present within the building. The system supports up to 255 addressable devices on its single loop, with a maximum loop length of 1km and loop output current of 450mA.
The LAP501/CA is ENVISION Enabled and compatible with C-TEC's cloud-based data management software, allowing incidents to be monitored either on or off site. It also provides two conventional sounder circuits, programmable auxiliary inputs and relays, a 24V auxiliary power output and comprehensive status indication via a two-line backlit display and 32 zonal LEDs.
The panel has been designed to help smaller venues prepare for the Terrorism (Protection of Premises) Act 2025, commonly known as Martyn's Law, which introduces public protection requirements including lockdown planning for certain premises and events.
Powered from a 230V AC mains supply, the panel supports two 12V 7Ah VRLA batteries connected in series for standby operation.
LAP501/CA
Dedicated single-message CAST lockdown and invacuation control panel
Broadcasts a full lockdown voice message when a CAST lockdown call point is activated
Fully monitored and battery backed
Single addressable loop supporting up to 255 devices
Maximum loop length of 1km
ENVISION Enabled for cloud-based incident monitoring
Two conventional sounder circuits
32 zonal LED indicators and two-line backlit display
Programmable auxiliary inputs and relay outputs
Specification | Details |
|---|---|
Model | LAP501/CA |
Protocol | C-TEC CAST |
Mains Supply | 230V 50/60Hz |
Mains Rated Current | 680mA maximum |
Internal Power Supply | 27Vdc nominal |
Total Output Current | Limited to 3A @ 230Vac (Imax.A 250mA; Imin. 70mA) |
Quiescent Current | 80mA (loop unloaded) |
Maximum Battery Size And Type | 2 x 12V 7Ah VRLA connected in series |
Number Of Loop Drivers | 1 |
Maximum Loop Output Current | 450mA (40V max) |
Maximum Loop Length | 1km |
Maximum Addressable Devices Per Loop | 255 |
Conventional Sounder Circuits | 2, maximum length per circuit 500m |
EOL Resistor Value | 6800Ω 5% Tol. 0.25W (blue, grey, red, gold) |
Maximum Sounder Output Current | 400mA |
Auxiliary Relays | 3 x programmable relays, 1 x fault relay, volt-free single pole changeover, max. switch current 1A, max. switch voltage 30Vdc |
Other Outputs | 24V Aux. Power, 19.5V min., 28V max., protected by resettable fuse, max. current 100mA |
Auxiliary Inputs | 2 x programmable inputs, connect to 0V to trigger, max. input voltage 27V, non-latching |
PC Connection | RS232 Molex connector, supplied in XFP507 upload/download software kit; no printer connection available |
Indicators | 2 line x 40 character backlit display; 32 zonal LEDs; General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault |
Connections | Fixed, largest acceptable conductor size 1mm² |
Expansion Connections | 2-wire RS485 non-redundant network/repeater connection via optional AFP711 network card |
Maximum Network Capacity | 8 mains per network, limit 1km, or 8 repeaters per non-networked main |
Base Dimensions | 410 W x 250 H x 80 D mm |
Lid Dimensions | 439 W x 274 H x 7 D mm |
Semi-Flush Mounting Hole | 412 W x 255 H x 50 D mm, requires XFP385 bezel |
Construction | Metal |
IP Rating | IP30 |
Weight | 4.5kg, no batteries |
Operating Temperature | -5ºC to +40ºC |
Maximum Relative Humidity | 95% |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.