Provide us with a few simple details, and our in-house engineers can produce your zone plan chart.
| Product | Price (ex VAT) | Quantity | Total (ex VAT) |
|---|---|---|---|
|
|
£
ex VAT
|
£0.00
|
1 item added to basket
C-TEC 8 Zone Fire Alarm Conventional Kit - Hochiki
We Recommend
Bestseller
Code: FDS100/520
INC VAT
Code: FDS100/520
The C-TEC 8 Zone Fire Alarm Conventional Kit – Hochiki provides a complete solution for starting a conventional fire alarm installation. Combining the reliable C-TEC CFP control panel with Hochiki detection devices, this kit includes the essential equipment required to begin protecting a premises quickly and efficiently.
Kit Contents
1 × C-TEC CFP708-4 8 Zone Conventional Fire Alarm Panel
4 × Hochiki SOC-E3N(WHT) Conventional Optical Smoke Detectors
1 × Hochiki DCD-AE3(WHT) Conventional Combined 60°C Heat Detector
5 × Hochiki YBN-R6SK Diode Bases
2 × Universal Conventional Manual Call Points
2 × FireSmart Sounders with Deep Bases
2 × FireSmart 12Vdc 3.2Ah Backup Batteries
Using the trusted Hochiki range of conventional detectors, the system delivers dependable fire detection performance alongside simple installation. This 4-wire conventional fire alarm system is designed for straightforward projects where reliability and compatibility are essential.
Additional devices can be selected from the options to configure the system to match the requirements of your premises.
Complete 8 zone conventional fire alarm starter kit
Built around the LPCB approved C-TEC CFP708-4 control panel
Hochiki optical smoke detectors for reliable fire detection
Hochiki combined heat detector suitable for temperature-based detection areas
Hochiki diode bases for secure detector installation
Resettable conventional manual call points compliant with EN54-11
FireSmart sounders with deep bases for clear audible alarm signalling
Backup batteries included for standby power during mains failure
Designed for straightforward installation and system configuration
Specification | 8 Zone Panel |
|---|---|
Approvals/Certifications | EN54 Parts 2 & 4 (LPCB), EN54-13 (Kiwa Telefication) |
Mains Supply | 230V 50/60Hz |
Mains Rated Current | 350mA max |
Internal Power Supply | 19V–28.5V (27V nominal), Ripple 7V max |
Total Output Current | 1.5A @ 230Vac (ImaxA eq 146mA) |
Quiescent Current | 25mA (mains failed, internal sounder active) |
Max Battery Size & Type | 2 x 12V 3.2Ah VRLA (Min. 1.2Ah) |
No. of Detector Zones | 8 (Max. 500m per circuit) |
Call Point Resistor Value | 470 to 680Ω |
Max Devices per Zone | Same |
No. of Sounder Circuits | 4 (Max. 500m per circuit) |
EOL Resistor Value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Alarm Voltage | 27V max, 20V min |
Max Sounder Output Current | 4 x 200mA (800mA total) |
Auxiliary Relays | 2: Aux. Fire & Fault, volt-free SPCO, 1A @ 30Vdc |
Open Collector Outputs | 2: Reset & Remote, 30mA max sink, 30V open circuit |
Other Outputs | 24V Aux Power, resettable fuse, 100mA min hold |
Auxiliary Inputs | 2: Class Change & Alert, 27V max input |
Engineer Functions | Coincidence, 1-man test, programmable delays, zone & sounder behaviour settings |
Expansion Connections | Yes – repeater/network/relay/sounder interface board compatible |
Product Dimensions (mm) | 380 W x 235 H x 96 D (Flush: 367 W x 220 H x 75 D) |
Construction & Finish | Plastic lid/base, RAL7035 textured |
IP Rating | IP30 |
Weight | 1.75kg (without batteries) |
Operating Conditions | -5ºC to +40ºC, 95% RH max |
The C-TEC 8 Zone Fire Alarm Conventional Kit – Hochiki provides a complete solution for starting a conventional fire alarm installation. Combining the reliable C-TEC CFP control panel with Hochiki detection devices, this kit includes the essential equipment required to begin protecting a premises quickly and efficiently.
Kit Contents
1 × C-TEC CFP708-4 8 Zone Conventional Fire Alarm Panel
4 × Hochiki SOC-E3N(WHT) Conventional Optical Smoke Detectors
1 × Hochiki DCD-AE3(WHT) Conventional Combined 60°C Heat Detector
5 × Hochiki YBN-R6SK Diode Bases
2 × Universal Conventional Manual Call Points
2 × FireSmart Sounders with Deep Bases
2 × FireSmart 12Vdc 3.2Ah Backup Batteries
Using the trusted Hochiki range of conventional detectors, the system delivers dependable fire detection performance alongside simple installation. This 4-wire conventional fire alarm system is designed for straightforward projects where reliability and compatibility are essential.
Additional devices can be selected from the options to configure the system to match the requirements of your premises.
Complete 8 zone conventional fire alarm starter kit
Built around the LPCB approved C-TEC CFP708-4 control panel
Hochiki optical smoke detectors for reliable fire detection
Hochiki combined heat detector suitable for temperature-based detection areas
Hochiki diode bases for secure detector installation
Resettable conventional manual call points compliant with EN54-11
FireSmart sounders with deep bases for clear audible alarm signalling
Backup batteries included for standby power during mains failure
Designed for straightforward installation and system configuration
Specification | 8 Zone Panel |
|---|---|
Approvals/Certifications | EN54 Parts 2 & 4 (LPCB), EN54-13 (Kiwa Telefication) |
Mains Supply | 230V 50/60Hz |
Mains Rated Current | 350mA max |
Internal Power Supply | 19V–28.5V (27V nominal), Ripple 7V max |
Total Output Current | 1.5A @ 230Vac (ImaxA eq 146mA) |
Quiescent Current | 25mA (mains failed, internal sounder active) |
Max Battery Size & Type | 2 x 12V 3.2Ah VRLA (Min. 1.2Ah) |
No. of Detector Zones | 8 (Max. 500m per circuit) |
Call Point Resistor Value | 470 to 680Ω |
Max Devices per Zone | Same |
No. of Sounder Circuits | 4 (Max. 500m per circuit) |
EOL Resistor Value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Alarm Voltage | 27V max, 20V min |
Max Sounder Output Current | 4 x 200mA (800mA total) |
Auxiliary Relays | 2: Aux. Fire & Fault, volt-free SPCO, 1A @ 30Vdc |
Open Collector Outputs | 2: Reset & Remote, 30mA max sink, 30V open circuit |
Other Outputs | 24V Aux Power, resettable fuse, 100mA min hold |
Auxiliary Inputs | 2: Class Change & Alert, 27V max input |
Engineer Functions | Coincidence, 1-man test, programmable delays, zone & sounder behaviour settings |
Expansion Connections | Yes – repeater/network/relay/sounder interface board compatible |
Product Dimensions (mm) | 380 W x 235 H x 96 D (Flush: 367 W x 220 H x 75 D) |
Construction & Finish | Plastic lid/base, RAL7035 textured |
IP Rating | IP30 |
Weight | 1.75kg (without batteries) |
Operating Conditions | -5ºC to +40ºC, 95% RH max |
FDS330/900
FDS330/901
FDS330/902
FDS331/283
FDS340/041
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.