C-TEC 4 Zone Fire Alarm Conventional Kit - FireSmart
We Recommend
Bestseller
Code: FDS130/451
INC VAT
Code: FDS130/451
The C-TEC 4 Zone Fire Alarm Conventional Kit – FireSmart provides a complete conventional fire detection solution using the trusted C-TEC control panel and FireSmart detection devices. Designed to simplify installation, the kit includes all the essential components required to begin installing a fire alarm system in one convenient package.
Kit Contents
1 x C-TEC CFP704-4 4 Zone Conventional Fire Alarm Panel
4 x FireSmart Optical Smoke Detectors
1 x FireSmart Rate-of-Rise Heat Detector
2 x FireSmart Conventional Manual Call Points
2 x FireSmart Sounders with Deep Bases
2 x FireSmart 12Vdc 3.4Ah Backup Batteries
Using devices from the reliable FireSmart range, the kit delivers a straightforward and cost-effective solution for protecting small to medium sized premises. All components are selected for compatibility, helping installers achieve a quick installation while ensuring dependable fire detection and alarm signalling.
The system includes optical smoke detectors for general detection areas, a rate-of-rise heat detector for locations where smoke detection may not be suitable, manual call points for manual activation and sounders to provide clear audible alarm notification.
Complete conventional fire alarm kit using FireSmart detection devices
Built around the LPCB approved C-TEC CFP704-4 4 zone conventional fire alarm panel
FireSmart optical smoke detectors for reliable fire detection
Rate-of-rise heat detector suitable for kitchens or high humidity environments
Resettable FireSmart manual call points compliant with EN54-11
FireSmart sounders with bases provide clear audible alarm signalling
Backup batteries included for standby power during mains failure
Fully compatible components designed for reliable system performance
Ideal for small to medium sized commercial premises
Simplifies system specification, ordering and installation
Specification | 4 Zone Panel |
|---|---|
Approvals/Certifications | EN54 Parts 2 & 4 (LPCB), EN54-13 (Kiwa Telefication) |
Mains Supply | 230V 50/60Hz |
Mains Rated Current | 350mA max |
Internal Power Supply | 19V–28.5V (27V nominal), Ripple 7V max |
Total Output Current | 1.5A @ 230Vac (ImaxA eq 146mA) |
Quiescent Current | 25mA (mains failed, internal sounder active) |
Max Battery Size & Type | 2 x 12V 3.2Ah VRLA (Min. 1.2Ah) |
No. of Detector Zones | 4 (Max. 500m per circuit) |
Call Point Resistor Value | 470 to 680Ω |
Max Devices per Zone | Same |
No. of Sounder Circuits | 4 (Max. 500m per circuit) |
EOL Resistor Value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Alarm Voltage | 27V max, 20V min |
Max Sounder Output Current | 4 x 200mA (800mA total) |
Auxiliary Relays | 2: Aux. Fire & Fault, volt-free SPCO, 1A @ 30Vdc |
Open Collector Outputs | 2: Reset & Remote, 30mA max sink, 30V open circuit |
Other Outputs | 24V Aux Power, resettable fuse, 100mA min hold |
Auxiliary Inputs | 2: Class Change & Alert, 27V max input |
Engineer Functions | Coincidence, 1-man test, programmable delays, zone & sounder behaviour settings |
Expansion Connections | Yes – repeater/network/relay/sounder interface board compatible |
Product Dimensions (mm) | 380 W x 235 H x 96 D (Flush: 367 W x 220 H x 75 D) |
Construction & Finish | Plastic lid/base, RAL7035 textured |
IP Rating | IP30 |
Weight | 1.75kg (without batteries) |
Operating Conditions | -5ºC to +40ºC, 95% RH max |
The C-TEC 4 Zone Fire Alarm Conventional Kit – FireSmart provides a complete conventional fire detection solution using the trusted C-TEC control panel and FireSmart detection devices. Designed to simplify installation, the kit includes all the essential components required to begin installing a fire alarm system in one convenient package.
Kit Contents
1 x C-TEC CFP704-4 4 Zone Conventional Fire Alarm Panel
4 x FireSmart Optical Smoke Detectors
1 x FireSmart Rate-of-Rise Heat Detector
2 x FireSmart Conventional Manual Call Points
2 x FireSmart Sounders with Deep Bases
2 x FireSmart 12Vdc 3.4Ah Backup Batteries
Using devices from the reliable FireSmart range, the kit delivers a straightforward and cost-effective solution for protecting small to medium sized premises. All components are selected for compatibility, helping installers achieve a quick installation while ensuring dependable fire detection and alarm signalling.
The system includes optical smoke detectors for general detection areas, a rate-of-rise heat detector for locations where smoke detection may not be suitable, manual call points for manual activation and sounders to provide clear audible alarm notification.
Complete conventional fire alarm kit using FireSmart detection devices
Built around the LPCB approved C-TEC CFP704-4 4 zone conventional fire alarm panel
FireSmart optical smoke detectors for reliable fire detection
Rate-of-rise heat detector suitable for kitchens or high humidity environments
Resettable FireSmart manual call points compliant with EN54-11
FireSmart sounders with bases provide clear audible alarm signalling
Backup batteries included for standby power during mains failure
Fully compatible components designed for reliable system performance
Ideal for small to medium sized commercial premises
Simplifies system specification, ordering and installation
Specification | 4 Zone Panel |
|---|---|
Approvals/Certifications | EN54 Parts 2 & 4 (LPCB), EN54-13 (Kiwa Telefication) |
Mains Supply | 230V 50/60Hz |
Mains Rated Current | 350mA max |
Internal Power Supply | 19V–28.5V (27V nominal), Ripple 7V max |
Total Output Current | 1.5A @ 230Vac (ImaxA eq 146mA) |
Quiescent Current | 25mA (mains failed, internal sounder active) |
Max Battery Size & Type | 2 x 12V 3.2Ah VRLA (Min. 1.2Ah) |
No. of Detector Zones | 4 (Max. 500m per circuit) |
Call Point Resistor Value | 470 to 680Ω |
Max Devices per Zone | Same |
No. of Sounder Circuits | 4 (Max. 500m per circuit) |
EOL Resistor Value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Alarm Voltage | 27V max, 20V min |
Max Sounder Output Current | 4 x 200mA (800mA total) |
Auxiliary Relays | 2: Aux. Fire & Fault, volt-free SPCO, 1A @ 30Vdc |
Open Collector Outputs | 2: Reset & Remote, 30mA max sink, 30V open circuit |
Other Outputs | 24V Aux Power, resettable fuse, 100mA min hold |
Auxiliary Inputs | 2: Class Change & Alert, 27V max input |
Engineer Functions | Coincidence, 1-man test, programmable delays, zone & sounder behaviour settings |
Expansion Connections | Yes – repeater/network/relay/sounder interface board compatible |
Product Dimensions (mm) | 380 W x 235 H x 96 D (Flush: 367 W x 220 H x 75 D) |
Construction & Finish | Plastic lid/base, RAL7035 textured |
IP Rating | IP30 |
Weight | 1.75kg (without batteries) |
Operating Conditions | -5ºC to +40ºC, 95% RH max |
FDS331/283
FDS340/041
FDS361/015
FDS130/350
FDS100/518
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.