Provide us with a few simple details, and our in-house engineers can produce your zone plan chart.
| Product | Price (ex VAT) | Quantity | Total (ex VAT) |
|---|---|---|---|
|
|
£
ex VAT
|
£0.00
|
We Recommend
Code: FDS372/440
INC VAT
Code: FDS372/440
The C-TEC 2 Zone Fire Alarm Conventional Kit – Orbis provides a practical, ready-to-install solution for small commercial premises and light industrial sites.
Built around the reliable C-TEC CFP702-4 control panel and Apollo Orbis conventional detection, this 4 wire system offers dependable fire detection at a competitive price point.
The kit includes Apollo Orbis optical smoke detectors for general areas and circulation spaces, alongside an A2S fixed temperature heat detector suited to kitchens or areas where smoke detectors may be prone to false alarms.
Conventional manual call points and sounders are supplied to provide straightforward alarm activation and clear audible warning throughout the premises.
Diode bases are included to ensure correct conventional circuit configuration, and standby batteries are provided for compliant backup power.
Additional devices can be selected using the options above to tailor the system to your specific site requirements and streamline the ordering process.
Complete 2 zone conventional fire alarm kit for small installations
C-TEC CFP702-4 2 zone conventional control panel included
Apollo Orbis conventional detection for modern, reliable performance
4 × Orbis optical smoke detectors for general areas and circulation spaces
1 × Orbis A2S fixed temperature heat detector for kitchens or higher nuisance areas
2 × conventional manual call points for straightforward alarm activation
5 × Orbis diode bases supplied for correct conventional circuit operation
2 × conventional sounders with deep bases for clear audible warning
2.2Ah battery twin pack included for standby power
Options available to add devices and build out the system to suit your site
Specification | C-TEC 2 Zone Panel |
|---|---|
Approvals/Certifications | EN54 Parts 2 & 4 (LPCB), EN54-13 (Kiwa Telefication) |
Mains Supply | 230V 50/60Hz |
Mains Rated Current | 350mA max |
Internal Power Supply | 19V–28.5V (27V nominal), Ripple 7V max |
Total Output Current | 1.5A @ 230Vac (ImaxA eq 146mA) |
Quiescent Current | 25mA (mains failed, internal sounder active) |
Max Battery Size & Type | 2 x 12V 3.2Ah VRLA (Min. 1.2Ah) |
No. of Detector Zones | 2 (Max. 500m per circuit) |
Call Point Resistor Value | 470 to 680Ω |
Max Devices per Zone | 25 detectors or 32 detectors/call points combined |
No. of Sounder Circuits | 4 (Max. 500m per circuit) |
EOL Resistor Value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Alarm Voltage | 27V max, 20V min |
Max Sounder Output Current | 4 x 200mA (800mA total) |
Auxiliary Relays | 2: Aux. Fire & Fault, volt-free SPCO, 1A @ 30Vdc |
Open Collector Outputs | 2: Reset & Remote, 30mA max sink, 30V open circuit |
Other Outputs | 24V Aux Power, resettable fuse, 100mA min hold |
Auxiliary Inputs | 2: Class Change & Alert, 27V max input |
Engineer Functions | Coincidence, 1-man test, programmable delays, zone & sounder behaviour settings |
Expansion Connections | Yes – repeater/network/relay/sounder interface board compatible |
Product Dimensions (mm) | 380 W x 235 H x 96 D (Flush: 367 W x 220 H x 75 D) |
Construction & Finish | Plastic lid/base, RAL7035 textured |
IP Rating | IP30 |
Weight | 1.75kg (without batteries) |
Operating Conditions | -5ºC to +40ºC, 95% RH max |
The C-TEC 2 Zone Fire Alarm Conventional Kit – Orbis provides a practical, ready-to-install solution for small commercial premises and light industrial sites.
Built around the reliable C-TEC CFP702-4 control panel and Apollo Orbis conventional detection, this 4 wire system offers dependable fire detection at a competitive price point.
The kit includes Apollo Orbis optical smoke detectors for general areas and circulation spaces, alongside an A2S fixed temperature heat detector suited to kitchens or areas where smoke detectors may be prone to false alarms.
Conventional manual call points and sounders are supplied to provide straightforward alarm activation and clear audible warning throughout the premises.
Diode bases are included to ensure correct conventional circuit configuration, and standby batteries are provided for compliant backup power.
Additional devices can be selected using the options above to tailor the system to your specific site requirements and streamline the ordering process.
Complete 2 zone conventional fire alarm kit for small installations
C-TEC CFP702-4 2 zone conventional control panel included
Apollo Orbis conventional detection for modern, reliable performance
4 × Orbis optical smoke detectors for general areas and circulation spaces
1 × Orbis A2S fixed temperature heat detector for kitchens or higher nuisance areas
2 × conventional manual call points for straightforward alarm activation
5 × Orbis diode bases supplied for correct conventional circuit operation
2 × conventional sounders with deep bases for clear audible warning
2.2Ah battery twin pack included for standby power
Options available to add devices and build out the system to suit your site
Specification | C-TEC 2 Zone Panel |
|---|---|
Approvals/Certifications | EN54 Parts 2 & 4 (LPCB), EN54-13 (Kiwa Telefication) |
Mains Supply | 230V 50/60Hz |
Mains Rated Current | 350mA max |
Internal Power Supply | 19V–28.5V (27V nominal), Ripple 7V max |
Total Output Current | 1.5A @ 230Vac (ImaxA eq 146mA) |
Quiescent Current | 25mA (mains failed, internal sounder active) |
Max Battery Size & Type | 2 x 12V 3.2Ah VRLA (Min. 1.2Ah) |
No. of Detector Zones | 2 (Max. 500m per circuit) |
Call Point Resistor Value | 470 to 680Ω |
Max Devices per Zone | 25 detectors or 32 detectors/call points combined |
No. of Sounder Circuits | 4 (Max. 500m per circuit) |
EOL Resistor Value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Alarm Voltage | 27V max, 20V min |
Max Sounder Output Current | 4 x 200mA (800mA total) |
Auxiliary Relays | 2: Aux. Fire & Fault, volt-free SPCO, 1A @ 30Vdc |
Open Collector Outputs | 2: Reset & Remote, 30mA max sink, 30V open circuit |
Other Outputs | 24V Aux Power, resettable fuse, 100mA min hold |
Auxiliary Inputs | 2: Class Change & Alert, 27V max input |
Engineer Functions | Coincidence, 1-man test, programmable delays, zone & sounder behaviour settings |
Expansion Connections | Yes – repeater/network/relay/sounder interface board compatible |
Product Dimensions (mm) | 380 W x 235 H x 96 D (Flush: 367 W x 220 H x 75 D) |
Construction & Finish | Plastic lid/base, RAL7035 textured |
IP Rating | IP30 |
Weight | 1.75kg (without batteries) |
Operating Conditions | -5ºC to +40ºC, 95% RH max |
FDS331/283
FDS340/041
FDS361/015
FDS130/350
FDS100/518
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.