The Ajax Residence Line FireProtect 2 SB (Heat/Smoke) Jeweller is a wireless fire detector combining smoke and heat detection in a single unit. Designed for use within an Ajax system, it uses sealed lithium batteries to provide up to 10 years of battery life, reducing routine battery maintenance over the detector's service period.
Smoke detection is handled by a dual-spectrum optical sensor working with the HazeFlow 2 software algorithm. This combination is designed to distinguish smoke from vapour and water steam, helping to reduce unwanted alarms. The smoke chamber is dustproof, resistant to insect ingress and requires no regular cleaning.
For heat detection, two A1R-class thermistors are positioned outside the enclosure to minimise detection delays. The detector raises an alarm if the temperature increases by 10°C within one minute or exceeds +64°C.
FireProtect 2 detectors can be interconnected using two parallel methods. Primary interconnection operates through an Ajax hub and can activate the built-in sirens of all fire detectors in the system within 20 seconds. A fallback detector-to-detector interconnection provides additional resilience if communication with the hub is unavailable.
Jeweller wireless communication provides a range of up to 1,700 metres in open space, with system supervision including regular polling, automatic self-diagnosis and maintenance notifications. A built-in 85 dB siren and LED status indication provide local alerts, while the SmartBracket mounting panel and QR code pairing support straightforward installation and setup.
Dual-spectrum optical smoke sensor with HazeFlow 2 algorithm
Two A1R-class thermistors for heat detection
Alarm activation at +64°C or a 10°C temperature rise within one minute
Sealed lithium batteries with up to 10 years of battery life
Primary hub-based and fallback detector-to-detector interconnection
Jeweller wireless communication range up to 1,700 m in open space
Built-in 85 dB siren with LED detector status indication
Automatic detector self-diagnosis and maintenance notifications
SmartBracket mounting panel and QR code pairing for installation and setup
Specification | Details |
|---|---|
Smoke Sensor | Dual-spectrum optical sensor |
Smoke Detection Algorithm | HazeFlow 2 |
Smoke Chamber | Dustproof, resistant to insects and requires no regular cleaning |
Heat Sensors | 2 × A1R-class thermistors |
Heat Alarm Threshold | Temperature rise of 10°C within 1 minute or exceeds +64°C |
Communication Technology | Jeweller |
Frequency Bands | 866.0–866.5 MHz; 868.0–868.6 MHz; 868.7–869.2 MHz; 905.0–926.5 MHz; 915.85–926.5 MHz; 921.0–922.0 MHz, depending on sales region |
Maximum Effective Radiated Power | Up to 20 mW |
Communication Range | Up to 1,700 m / 5,550 ft in open space |
Siren | Built-in 85 dB |
Power Supply | 2 × sealed lithium batteries |
Battery Life | Up to 10 years |
Operating Temperature Range | 0°C to +50°C / 32°F to 122°F |
Operating Humidity | Up to 80% |
Dimensions | 124 × 124 × 45 mm / 4.88 × 4.88 × 1.77 in |
Weight | 268.5 g / 9.47 oz |
Colour | White, black |
Protection Class | IP20 |
Compliance | EN 14604:2005/AC:2008; BS 5839-6 (Grade F1); AS 3786:2014; BS 5446-2:2003 |
Certification | BSI KITEMARK Heat Alarms KM 797644; BSI KITEMARK Smoke Alarms KM 797639 |
Complete Set | FireProtect 2 SB (Heat/Smoke) Jeweller, SmartBracket mounting panel, installation kit, quick start guide |
The Ajax Residence Line FireProtect 2 SB (Heat/Smoke) Jeweller is a wireless fire detector combining smoke and heat detection in a single unit. Designed for use within an Ajax system, it uses sealed lithium batteries to provide up to 10 years of battery life, reducing routine battery maintenance over the detector's service period.
Smoke detection is handled by a dual-spectrum optical sensor working with the HazeFlow 2 software algorithm. This combination is designed to distinguish smoke from vapour and water steam, helping to reduce unwanted alarms. The smoke chamber is dustproof, resistant to insect ingress and requires no regular cleaning.
For heat detection, two A1R-class thermistors are positioned outside the enclosure to minimise detection delays. The detector raises an alarm if the temperature increases by 10°C within one minute or exceeds +64°C.
FireProtect 2 detectors can be interconnected using two parallel methods. Primary interconnection operates through an Ajax hub and can activate the built-in sirens of all fire detectors in the system within 20 seconds. A fallback detector-to-detector interconnection provides additional resilience if communication with the hub is unavailable.
Jeweller wireless communication provides a range of up to 1,700 metres in open space, with system supervision including regular polling, automatic self-diagnosis and maintenance notifications. A built-in 85 dB siren and LED status indication provide local alerts, while the SmartBracket mounting panel and QR code pairing support straightforward installation and setup.
Dual-spectrum optical smoke sensor with HazeFlow 2 algorithm
Two A1R-class thermistors for heat detection
Alarm activation at +64°C or a 10°C temperature rise within one minute
Sealed lithium batteries with up to 10 years of battery life
Primary hub-based and fallback detector-to-detector interconnection
Jeweller wireless communication range up to 1,700 m in open space
Built-in 85 dB siren with LED detector status indication
Automatic detector self-diagnosis and maintenance notifications
SmartBracket mounting panel and QR code pairing for installation and setup
Specification | Details |
|---|---|
Smoke Sensor | Dual-spectrum optical sensor |
Smoke Detection Algorithm | HazeFlow 2 |
Smoke Chamber | Dustproof, resistant to insects and requires no regular cleaning |
Heat Sensors | 2 × A1R-class thermistors |
Heat Alarm Threshold | Temperature rise of 10°C within 1 minute or exceeds +64°C |
Communication Technology | Jeweller |
Frequency Bands | 866.0–866.5 MHz; 868.0–868.6 MHz; 868.7–869.2 MHz; 905.0–926.5 MHz; 915.85–926.5 MHz; 921.0–922.0 MHz, depending on sales region |
Maximum Effective Radiated Power | Up to 20 mW |
Communication Range | Up to 1,700 m / 5,550 ft in open space |
Siren | Built-in 85 dB |
Power Supply | 2 × sealed lithium batteries |
Battery Life | Up to 10 years |
Operating Temperature Range | 0°C to +50°C / 32°F to 122°F |
Operating Humidity | Up to 80% |
Dimensions | 124 × 124 × 45 mm / 4.88 × 4.88 × 1.77 in |
Weight | 268.5 g / 9.47 oz |
Colour | White, black |
Protection Class | IP20 |
Compliance | EN 14604:2005/AC:2008; BS 5839-6 (Grade F1); AS 3786:2014; BS 5446-2:2003 |
Certification | BSI KITEMARK Heat Alarms KM 797644; BSI KITEMARK Smoke Alarms KM 797639 |
Complete Set | FireProtect 2 SB (Heat/Smoke) Jeweller, SmartBracket mounting panel, installation kit, quick start guide |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.