The 4 Zone Contractor Fire Alarm Kit is a complete conventional fire detection solution designed for installers who require a reliable and cost-effective system for small to medium sized premises.
Kit Contents
1 × C-TEC CFP704-4 4 Zone Conventional Fire Alarm Panel
8 × FireSmart Optical Smoke Detectors
4 × FireSmart Universal Conventional Manual Call Points
4 × FireSmart Conventional Sounders
2 × FireSmart 12Vdc 3.2Ah Backup Batteries
1 × FireSmart Fire Alarm Log Book
Carefully selected by the engineers at Fire Detection Shop, this contractor kit combines the trusted C-TEC CFP704-4 conventional fire alarm panel with compatible FireSmart detection and alarm devices. By supplying a fully matched set of components, the kit simplifies ordering while ensuring dependable system performance and straightforward installation.
Ideal for offices, retail units, workshops and similar commercial buildings, the kit provides effective fire detection and clear alarm signalling through a combination of optical smoke detectors, manual call points and sounders.
Complete conventional fire alarm kit designed for contractor installations
Built around the C-TEC CFP704-4 LPCB approved 4 zone fire alarm panel
FireSmart optical smoke detectors for reliable fire detection
Resettable FireSmart manual call points for manual alarm activation
FireSmart sounders providing clear audible alarm signalling
Backup batteries included for standby power in the event of mains failure
Supplied with fire alarm log book for recording maintenance and service history
Compatible FireSmart devices designed for reliable system operation
Ideal for small to medium sized commercial premises
Simplifies system specification, ordering and installation
Specification | 4 Zone Panel |
|---|---|
Approvals/Certifications | EN54 Parts 2 & 4 (LPCB), EN54-13 (Kiwa Telefication) |
Mains Supply | 230V 50/60Hz |
Mains Rated Current | 350mA max |
Internal Power Supply | 19V–28.5V (27V nominal), Ripple 7V max |
Total Output Current | 1.5A @ 230Vac (ImaxA eq 146mA) |
Quiescent Current | 25mA (mains failed, internal sounder active) |
Max Battery Size & Type | 2 x 12V 3.2Ah VRLA (Min. 1.2Ah) |
No. of Detector Zones | 4 (Max. 500m per circuit) |
Call Point Resistor Value | 470 to 680Ω |
Max Devices per Zone | Same |
No. of Sounder Circuits | 4 (Max. 500m per circuit) |
EOL Resistor Value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Alarm Voltage | 27V max, 20V min |
Max Sounder Output Current | 4 x 200mA (800mA total) |
Auxiliary Relays | 2: Aux. Fire & Fault, volt-free SPCO, 1A @ 30Vdc |
Open Collector Outputs | 2: Reset & Remote, 30mA max sink, 30V open circuit |
Other Outputs | 24V Aux Power, resettable fuse, 100mA min hold |
Auxiliary Inputs | 2: Class Change & Alert, 27V max input |
Engineer Functions | Coincidence, 1-man test, programmable delays, zone & sounder behaviour settings |
Expansion Connections | Yes – repeater/network/relay/sounder interface board compatible |
Product Dimensions (mm) | 380 W x 235 H x 96 D (Flush: 367 W x 220 H x 75 D) |
Construction & Finish | Plastic lid/base, RAL7035 textured |
IP Rating | IP30 |
Weight | 1.75kg (without batteries) |
Operating Conditions | -5ºC to +40ºC, 95% RH max |
The 4 Zone Contractor Fire Alarm Kit is a complete conventional fire detection solution designed for installers who require a reliable and cost-effective system for small to medium sized premises.
Kit Contents
1 × C-TEC CFP704-4 4 Zone Conventional Fire Alarm Panel
8 × FireSmart Optical Smoke Detectors
4 × FireSmart Universal Conventional Manual Call Points
4 × FireSmart Conventional Sounders
2 × FireSmart 12Vdc 3.2Ah Backup Batteries
1 × FireSmart Fire Alarm Log Book
Carefully selected by the engineers at Fire Detection Shop, this contractor kit combines the trusted C-TEC CFP704-4 conventional fire alarm panel with compatible FireSmart detection and alarm devices. By supplying a fully matched set of components, the kit simplifies ordering while ensuring dependable system performance and straightforward installation.
Ideal for offices, retail units, workshops and similar commercial buildings, the kit provides effective fire detection and clear alarm signalling through a combination of optical smoke detectors, manual call points and sounders.
Complete conventional fire alarm kit designed for contractor installations
Built around the C-TEC CFP704-4 LPCB approved 4 zone fire alarm panel
FireSmart optical smoke detectors for reliable fire detection
Resettable FireSmart manual call points for manual alarm activation
FireSmart sounders providing clear audible alarm signalling
Backup batteries included for standby power in the event of mains failure
Supplied with fire alarm log book for recording maintenance and service history
Compatible FireSmart devices designed for reliable system operation
Ideal for small to medium sized commercial premises
Simplifies system specification, ordering and installation
Specification | 4 Zone Panel |
|---|---|
Approvals/Certifications | EN54 Parts 2 & 4 (LPCB), EN54-13 (Kiwa Telefication) |
Mains Supply | 230V 50/60Hz |
Mains Rated Current | 350mA max |
Internal Power Supply | 19V–28.5V (27V nominal), Ripple 7V max |
Total Output Current | 1.5A @ 230Vac (ImaxA eq 146mA) |
Quiescent Current | 25mA (mains failed, internal sounder active) |
Max Battery Size & Type | 2 x 12V 3.2Ah VRLA (Min. 1.2Ah) |
No. of Detector Zones | 4 (Max. 500m per circuit) |
Call Point Resistor Value | 470 to 680Ω |
Max Devices per Zone | Same |
No. of Sounder Circuits | 4 (Max. 500m per circuit) |
EOL Resistor Value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Alarm Voltage | 27V max, 20V min |
Max Sounder Output Current | 4 x 200mA (800mA total) |
Auxiliary Relays | 2: Aux. Fire & Fault, volt-free SPCO, 1A @ 30Vdc |
Open Collector Outputs | 2: Reset & Remote, 30mA max sink, 30V open circuit |
Other Outputs | 24V Aux Power, resettable fuse, 100mA min hold |
Auxiliary Inputs | 2: Class Change & Alert, 27V max input |
Engineer Functions | Coincidence, 1-man test, programmable delays, zone & sounder behaviour settings |
Expansion Connections | Yes – repeater/network/relay/sounder interface board compatible |
Product Dimensions (mm) | 380 W x 235 H x 96 D (Flush: 367 W x 220 H x 75 D) |
Construction & Finish | Plastic lid/base, RAL7035 textured |
IP Rating | IP30 |
Weight | 1.75kg (without batteries) |
Operating Conditions | -5ºC to +40ºC, 95% RH max |
FDS500/666
FDS330/900
FDS330/901
FDS330/902
FDS331/283
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.