Provide us with a few simple details, and our in-house engineers can produce your zone plan chart.
| Product | Price (ex VAT) | Quantity | Total (ex VAT) |
|---|---|---|---|
|
|
£
ex VAT
|
£0.00
|
Code: FDS002/636
INC VAT
Code: FDS002/636
The Zeta Infinity ID2 Intelligent Bi-Wire (2-Wire) Fire Alarm Control Panel is a hard and soft addressable fire detection system designed to deliver the benefits of intelligent identification while retaining the simplicity of a two-wire installation.
Built on Zeta’s proven communication protocol, the ID2 system allows every device on the circuit to be uniquely identified by the panel, improving fault diagnosis, alarm verification and system management. Devices are connected using standard two-core zone cable on radial circuits, eliminating the need for separate sounder wiring or end-of-line components.
The ID2 range is ideal for new installations, retrofits of conventional systems, or upgrades of existing two-wire systems where additional intelligence and compliance are required without full re-cabling. Full compatibility with the ID2 Smartphone App enables fast device identification and commissioning directly from a mobile device.
The control panels are fully compliant with BS EN 5839-1 and BS EN 5839-6, and are certified to EN54-2 and EN54-4, making them suitable for a wide range of commercial fire alarm applications.
Intelligent 2-wire fire detection system with device identification
Available in 2, 4 or 8 zone variants (ID2/2, ID2/4, ID2/8)
Devices connected on radial circuits using standard two-core cable
No end-of-line components required
Supports 15 devices per zone
Up to 2048 event history with alarm and diagnostic logging
Alarm verification and device count verification
Built-in cable break and short-circuit protection
Loop-powered sounders with no separate sounder circuits required
Detectors available with integrated sounders
ID2 Smartphone App for device identification and commissioning
RS485 repeater connection supported
Suitable for new installations, retrofits, and system upgrades
Fully compliant with EN54-2, EN54-4 and BS EN 5839 Parts 1 & 6
Specification | ID2/2 | ID2/4 | ID2/8 |
|---|---|---|---|
Part Number | 37-660 | 37-661 | 37-663 |
Supply Voltage | 230V AC ±10% / −15% @ 50/60Hz | 230V AC ±10% / −15% @ 50/60Hz | 230V AC ±10% / −15% @ 50/60Hz |
System Voltage | 29V DC nominal (19–30V) | 29V DC nominal (19–30V) | 29V DC nominal (19–30V) |
Number of Zones | 2 | 4 | 8 |
Zone Capacity | Up to 15 devices per zone | Up to 15 devices per zone | Up to 15 devices per zone |
Detection Circuits | Radial mode: up to 8 radials or loop mode: 1 loop | Radial mode: up to 8 radials or loop mode: 1 loop | Radial mode: up to 8 radials or loop mode: 1 loop |
Maximum Loop Sounders | Up to 80 loop-powered sounders | Up to 80 loop-powered sounders | Up to 80 loop-powered sounders |
Sounder Output | 2 × conventional sounder circuits, 28V nominal, 150mA | 2 × conventional sounder circuits, 28V nominal, 150mA | 2 × conventional sounder circuits, 28V nominal, 150mA |
Fire Output | 1 × fire relay, SELV rated at 1A | 1 × fire relay, SELV rated at 1A | 1 × fire relay, SELV rated at 1A |
Fault Output | 1 × fault relay, SELV rated at 1A, normally energised | 1 × fault relay, SELV rated at 1A, normally energised | 1 × fault relay, SELV rated at 1A, normally energised |
Repeater Connection | RS485 repeater interface | RS485 repeater interface | RS485 repeater interface |
Event Memory | 2048 alarm and diagnostic events | 2048 alarm and diagnostic events | 2048 alarm and diagnostic events |
Dimensions (W × H × D) | 370 × 311 × 113 mm | 370 × 311 × 113 mm | 370 × 311 × 113 mm |
Weight | 2.65 kg | 2.65 kg | 2.65 kg |
Certification | EN54-2 and EN54-4 | EN54-2 and EN54-4 | EN54-2 and EN54-4 |
The Zeta Infinity ID2 Intelligent Bi-Wire (2-Wire) Fire Alarm Control Panel is a hard and soft addressable fire detection system designed to deliver the benefits of intelligent identification while retaining the simplicity of a two-wire installation.
Built on Zeta’s proven communication protocol, the ID2 system allows every device on the circuit to be uniquely identified by the panel, improving fault diagnosis, alarm verification and system management. Devices are connected using standard two-core zone cable on radial circuits, eliminating the need for separate sounder wiring or end-of-line components.
The ID2 range is ideal for new installations, retrofits of conventional systems, or upgrades of existing two-wire systems where additional intelligence and compliance are required without full re-cabling. Full compatibility with the ID2 Smartphone App enables fast device identification and commissioning directly from a mobile device.
The control panels are fully compliant with BS EN 5839-1 and BS EN 5839-6, and are certified to EN54-2 and EN54-4, making them suitable for a wide range of commercial fire alarm applications.
Intelligent 2-wire fire detection system with device identification
Available in 2, 4 or 8 zone variants (ID2/2, ID2/4, ID2/8)
Devices connected on radial circuits using standard two-core cable
No end-of-line components required
Supports 15 devices per zone
Up to 2048 event history with alarm and diagnostic logging
Alarm verification and device count verification
Built-in cable break and short-circuit protection
Loop-powered sounders with no separate sounder circuits required
Detectors available with integrated sounders
ID2 Smartphone App for device identification and commissioning
RS485 repeater connection supported
Suitable for new installations, retrofits, and system upgrades
Fully compliant with EN54-2, EN54-4 and BS EN 5839 Parts 1 & 6
Specification | ID2/2 | ID2/4 | ID2/8 |
|---|---|---|---|
Part Number | 37-660 | 37-661 | 37-663 |
Supply Voltage | 230V AC ±10% / −15% @ 50/60Hz | 230V AC ±10% / −15% @ 50/60Hz | 230V AC ±10% / −15% @ 50/60Hz |
System Voltage | 29V DC nominal (19–30V) | 29V DC nominal (19–30V) | 29V DC nominal (19–30V) |
Number of Zones | 2 | 4 | 8 |
Zone Capacity | Up to 15 devices per zone | Up to 15 devices per zone | Up to 15 devices per zone |
Detection Circuits | Radial mode: up to 8 radials or loop mode: 1 loop | Radial mode: up to 8 radials or loop mode: 1 loop | Radial mode: up to 8 radials or loop mode: 1 loop |
Maximum Loop Sounders | Up to 80 loop-powered sounders | Up to 80 loop-powered sounders | Up to 80 loop-powered sounders |
Sounder Output | 2 × conventional sounder circuits, 28V nominal, 150mA | 2 × conventional sounder circuits, 28V nominal, 150mA | 2 × conventional sounder circuits, 28V nominal, 150mA |
Fire Output | 1 × fire relay, SELV rated at 1A | 1 × fire relay, SELV rated at 1A | 1 × fire relay, SELV rated at 1A |
Fault Output | 1 × fault relay, SELV rated at 1A, normally energised | 1 × fault relay, SELV rated at 1A, normally energised | 1 × fault relay, SELV rated at 1A, normally energised |
Repeater Connection | RS485 repeater interface | RS485 repeater interface | RS485 repeater interface |
Event Memory | 2048 alarm and diagnostic events | 2048 alarm and diagnostic events | 2048 alarm and diagnostic events |
Dimensions (W × H × D) | 370 × 311 × 113 mm | 370 × 311 × 113 mm | 370 × 311 × 113 mm |
Weight | 2.65 kg | 2.65 kg | 2.65 kg |
Certification | EN54-2 and EN54-4 | EN54-2 and EN54-4 | EN54-2 and EN54-4 |
FDS100/442P
FDS300/028P
FDS100/365P
FDS100/447P
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.