The KAC CWSO-RR Red Conventional Fire Alarm Sounder is a high-performance audible warning device designed for use with conventional fire alarm systems.
Providing powerful and reliable alarm signalling, this red conventional fire alarm sounder delivers up to 107dB at 1 metre, ensuring clear and effective evacuation alerts in commercial, industrial and public buildings.
Approved to EN54-3, the CWSO-RR combines strong acoustic performance with low current consumption, making it suitable for a wide range of conventional fire alarm installations where dependable audible warning is essential.
The sounder features a robust red housing and an IP65-rated deep base option, allowing it to be installed in both indoor environments and more demanding locations where additional environmental protection is required.
Designed with installers in mind, the unit includes multiple cable entry points, common fixing centres and a positive fit base that provides clear engagement feedback during installation.
With 32 selectable tones and adjustable volume settings, the KAC CWSO-RR conventional sounder offers flexibility to suit different building requirements while maintaining full EN54-3 compliance.
KAC CWSO-RR-W1/S1
Compatible with all conventional systems
Deep base option with multiple cable entries for flexible installation.
9 - 28vdc voltage range.
Selectable volume.
IP65 rated
Designed with full range of common fixing centres.
Positive fit engagement and feedback of base with device for easy installation.
Approved to EN54-3.
32 tones all approved to EN54-3.
107dB @ 1m
Specification | Details |
|---|---|
Operating Voltage | 9 to 29 VDC (Approved to EN54-3 @ 9–14V and 18–29V) |
Average Current Consumption | 31 mA @ 29 VDC (Tone 8) |
Maximum Sound Output | 107 dB(A) @ 1 m (Tone 23) |
Operating Temperature | -25°C to 70°C |
Relative Humidity | 93% ±3% non-condensing |
Ingress Protection | IP21C (low profile base), IP65 (deep base) |
Body Colour | Red / White |
Number of Tones | 32 (includes bell tone) |
Volume Setting | High or Medium |
Cable Termination Size | 0.5 – 2.5 mm² |
Material | Flame retardant PC/ABS |
Gross Weight – Standard Device | Low profile: 190 g / Deep (IP65): 197 g |
Gross Weight – First Fix Option | Low profile: 200 g / Deep (IP65): 207 g |
The KAC CWSO-RR Red Conventional Fire Alarm Sounder is a high-performance audible warning device designed for use with conventional fire alarm systems.
Providing powerful and reliable alarm signalling, this red conventional fire alarm sounder delivers up to 107dB at 1 metre, ensuring clear and effective evacuation alerts in commercial, industrial and public buildings.
Approved to EN54-3, the CWSO-RR combines strong acoustic performance with low current consumption, making it suitable for a wide range of conventional fire alarm installations where dependable audible warning is essential.
The sounder features a robust red housing and an IP65-rated deep base option, allowing it to be installed in both indoor environments and more demanding locations where additional environmental protection is required.
Designed with installers in mind, the unit includes multiple cable entry points, common fixing centres and a positive fit base that provides clear engagement feedback during installation.
With 32 selectable tones and adjustable volume settings, the KAC CWSO-RR conventional sounder offers flexibility to suit different building requirements while maintaining full EN54-3 compliance.
KAC CWSO-RR-W1/S1
Compatible with all conventional systems
Deep base option with multiple cable entries for flexible installation.
9 - 28vdc voltage range.
Selectable volume.
IP65 rated
Designed with full range of common fixing centres.
Positive fit engagement and feedback of base with device for easy installation.
Approved to EN54-3.
32 tones all approved to EN54-3.
107dB @ 1m
Specification | Details |
|---|---|
Operating Voltage | 9 to 29 VDC (Approved to EN54-3 @ 9–14V and 18–29V) |
Average Current Consumption | 31 mA @ 29 VDC (Tone 8) |
Maximum Sound Output | 107 dB(A) @ 1 m (Tone 23) |
Operating Temperature | -25°C to 70°C |
Relative Humidity | 93% ±3% non-condensing |
Ingress Protection | IP21C (low profile base), IP65 (deep base) |
Body Colour | Red / White |
Number of Tones | 32 (includes bell tone) |
Volume Setting | High or Medium |
Cable Termination Size | 0.5 – 2.5 mm² |
Material | Flame retardant PC/ABS |
Gross Weight – Standard Device | Low profile: 190 g / Deep (IP65): 197 g |
Gross Weight – First Fix Option | Low profile: 200 g / Deep (IP65): 207 g |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.