The Apollo 55000-190APO AlarmSense A1R Standard Heat Detector is designed for reliable heat detection in environments where smoke detectors may not be suitable.
This A1R classified detector provides both a fixed upper temperature limit of 57°C and rate-of-rise detection, responding to rapid temperature increases of approximately 12–15°C per minute for faster fire recognition.
Part of the AlarmSense range, this detector is engineered for two-wire conventional systems, allowing detectors, sounders and call points to be connected on a single pair of cables. This simplifies installation, reduces wiring costs and improves system efficiency.
The unit features a clear 360° LED indicator for easy visual status confirmation and is suitable for kitchens, plant rooms, workshops and other areas prone to dust, steam or fumes.
A compatible base is required and is supplied separately.
Apollo 55000-190APO
Can be used for applications where smoke detectors are unsuitable
Ideal environments that are dirty or smoky under normal conditions
360 visibility of LED
Reduction of false alarms
Quick and simple 2 wire installation
Base supplied separately (please see related products below)
Specification | Value |
|---|---|
Detection principle | Heat sensitive resistance using a single NTC thermistor |
Sampling frequency | Once every four seconds |
Supply voltage | 9 Vdc to 33 Vdc |
Supply wiring | Two wire supply, polarity insensitive |
Quiescent current at 15 V | < 50 µA |
Alarm current (2–8.5 V) | < 1.5 mA |
Alarm current (10.5–15 V) | 25 ± 2 mA |
Alarm current (18–24 V) | < 1.5 mA |
Alarm current (33 V) | < 2 mA |
Maximum reset voltage | 2 V |
Reset time | 1 second |
Maximum supply interruption time | 40 ms |
Operating temperature (A1R) | -40°C to +50°C |
Operating temperature (CS) | -40°C to +80°C |
Humidity | 0% to 95% RH (no condensation or icing) |
IP Rating | Designed to IP44 |
Standards and approvals | EN 54-5, CPR and FDG |
Dimensions | 100 mm diameter × 42 mm height |
Dimensions in base | 100 mm diameter × 50 mm height |
Weight | 80 g (detector) |
Materials – Housing | White flame-retardant polycarbonate |
Materials – Terminals | Nickel plated stainless steel |
The Apollo 55000-190APO AlarmSense A1R Standard Heat Detector is designed for reliable heat detection in environments where smoke detectors may not be suitable.
This A1R classified detector provides both a fixed upper temperature limit of 57°C and rate-of-rise detection, responding to rapid temperature increases of approximately 12–15°C per minute for faster fire recognition.
Part of the AlarmSense range, this detector is engineered for two-wire conventional systems, allowing detectors, sounders and call points to be connected on a single pair of cables. This simplifies installation, reduces wiring costs and improves system efficiency.
The unit features a clear 360° LED indicator for easy visual status confirmation and is suitable for kitchens, plant rooms, workshops and other areas prone to dust, steam or fumes.
A compatible base is required and is supplied separately.
Apollo 55000-190APO
Can be used for applications where smoke detectors are unsuitable
Ideal environments that are dirty or smoky under normal conditions
360 visibility of LED
Reduction of false alarms
Quick and simple 2 wire installation
Base supplied separately (please see related products below)
Specification | Value |
|---|---|
Detection principle | Heat sensitive resistance using a single NTC thermistor |
Sampling frequency | Once every four seconds |
Supply voltage | 9 Vdc to 33 Vdc |
Supply wiring | Two wire supply, polarity insensitive |
Quiescent current at 15 V | < 50 µA |
Alarm current (2–8.5 V) | < 1.5 mA |
Alarm current (10.5–15 V) | 25 ± 2 mA |
Alarm current (18–24 V) | < 1.5 mA |
Alarm current (33 V) | < 2 mA |
Maximum reset voltage | 2 V |
Reset time | 1 second |
Maximum supply interruption time | 40 ms |
Operating temperature (A1R) | -40°C to +50°C |
Operating temperature (CS) | -40°C to +80°C |
Humidity | 0% to 95% RH (no condensation or icing) |
IP Rating | Designed to IP44 |
Standards and approvals | EN 54-5, CPR and FDG |
Dimensions | 100 mm diameter × 42 mm height |
Dimensions in base | 100 mm diameter × 50 mm height |
Weight | 80 g (detector) |
Materials – Housing | White flame-retardant polycarbonate |
Materials – Terminals | Nickel plated stainless steel |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.