The SmartCell SC-41-0200-0001 Wireless Dual Input / Output Unit is designed to provide wireless monitoring and control of third-party equipment as part of the SmartCell wireless fire alarm system.
This module allows seamless integration with auxiliary systems such as fire doors, plant shutdowns, ventilation systems, lifts and sprinkler interfaces, enabling both input monitoring and output control during fire alarm events.
Featuring two monitored inputs and two voltage-free relay outputs, the SC-41-0200-0001 supports flexible cause-and-effect programming within the SmartCell system.
Operating on the secure SmartCell 868 MHz wireless platform, the unit enables cable-free installation and is powered by long-life lithium batteries to reduce installation time and ongoing maintenance.
Fully compliant with EN 54-18 (Input/Output devices) and EN 54-25 (Wireless fire alarm systems), this device is suitable for residential, HMO and light commercial applications where reliable wireless integration is required.
Wireless dual input / output module for SmartCell systems
Two monitored inputs for external device status
Two voltage-free relay outputs for control functions
Fully compliant with EN 54-18 and EN 54-25
Operates on SmartCell secure 868 MHz wireless network
Battery powered for fast, cable-free installation
Suitable for fire doors, HVAC shutdowns, lifts and plant interfaces
Supplied with 3 × 3.6 V lithium batteries
Ideal for residential, HMO and light commercial systems
Category | Specification |
|---|---|
General | Wireless frequency: 868 MHz |
Input | Input quantity: 2 |
Input type and rating: Resistor monitored inputs | |
Output | Output quantity: 2 |
Output type and rating: Voltage free outputs, rated 1 A at 30 VDC | |
Physical | Dimensions: 150 × 200 × 55 mm (W × H × D) |
Net weight: 0.45 kg | |
Mounting type: Wall mount | |
Batteries: 3 × ER14505M 3.6 V lithium thionyl chloride batteries (Fanso or Titus) | |
Environmental | Operating temperature: -10 to +55°C |
Storage temperature: -10 to +30°C (with batteries) | |
Storage temperature: -10 to +55°C (without batteries) | |
Relative humidity: 95% noncondensing max. | |
Environment: Indoor | |
Regulatory | Compliancy: CE |
Certification: CPR | |
Standards: EN54-13 | |
Standards: EN54-18 | |
Standards: EN54-25 |
The SmartCell SC-41-0200-0001 Wireless Dual Input / Output Unit is designed to provide wireless monitoring and control of third-party equipment as part of the SmartCell wireless fire alarm system.
This module allows seamless integration with auxiliary systems such as fire doors, plant shutdowns, ventilation systems, lifts and sprinkler interfaces, enabling both input monitoring and output control during fire alarm events.
Featuring two monitored inputs and two voltage-free relay outputs, the SC-41-0200-0001 supports flexible cause-and-effect programming within the SmartCell system.
Operating on the secure SmartCell 868 MHz wireless platform, the unit enables cable-free installation and is powered by long-life lithium batteries to reduce installation time and ongoing maintenance.
Fully compliant with EN 54-18 (Input/Output devices) and EN 54-25 (Wireless fire alarm systems), this device is suitable for residential, HMO and light commercial applications where reliable wireless integration is required.
Wireless dual input / output module for SmartCell systems
Two monitored inputs for external device status
Two voltage-free relay outputs for control functions
Fully compliant with EN 54-18 and EN 54-25
Operates on SmartCell secure 868 MHz wireless network
Battery powered for fast, cable-free installation
Suitable for fire doors, HVAC shutdowns, lifts and plant interfaces
Supplied with 3 × 3.6 V lithium batteries
Ideal for residential, HMO and light commercial systems
Category | Specification |
|---|---|
General | Wireless frequency: 868 MHz |
Input | Input quantity: 2 |
Input type and rating: Resistor monitored inputs | |
Output | Output quantity: 2 |
Output type and rating: Voltage free outputs, rated 1 A at 30 VDC | |
Physical | Dimensions: 150 × 200 × 55 mm (W × H × D) |
Net weight: 0.45 kg | |
Mounting type: Wall mount | |
Batteries: 3 × ER14505M 3.6 V lithium thionyl chloride batteries (Fanso or Titus) | |
Environmental | Operating temperature: -10 to +55°C |
Storage temperature: -10 to +30°C (with batteries) | |
Storage temperature: -10 to +55°C (without batteries) | |
Relative humidity: 95% noncondensing max. | |
Environment: Indoor | |
Regulatory | Compliancy: CE |
Certification: CPR | |
Standards: EN54-13 | |
Standards: EN54-18 | |
Standards: EN54-25 |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.