The Haes SZAOV-1001 is a single zone Automatic Opening Vent control panel designed to manage smoke vents, windows and rooflights in fire and ventilation scenarios.
It supports conventional or twin wire detection and uses the same detection circuit technology as Haes EN54 approved fire control panels.
All vent controls and status indications are located on the front of the panel, making operation clear and intuitive for engineers and building managers.
The panel includes an integral 3A power supply with battery backup to ensure continued operation during mains failure.
Additional functionality such as rain sensors, PIR inputs and BMS integration can be added via a simple plug-in PCB, allowing the system to be tailored to site requirements.
Manufactured in the UK, the SZAOV-1001 is a robust and flexible solution for compliant smoke control applications.
Single zone Automatic Opening Vent control panel
Conventional or twin wire detection compatibility
Integral 3A power supply with battery backup
Front-mounted vent controls and status indications
Fireman’s control inputs for Open, Close and Auto
Monitored actuator output for 24V DC vents or magnets
False alarm management mode to reduce call-outs
Disable and test modes for maintenance
Thermostat input for controlled ventilation mode
Optional PIR, rain sensor and BMS inputs via add-on PCB
UK manufactured and CE certified
Item | Specification |
|---|---|
Enclosure | 1.2 mm Mild Steel IP30. Colour ref: MW334E Interpon powder coat |
Cable Entry | Via 20 mm knockouts located in the top and rear of the cabinet |
Dimensions | Back box: 310 mm W × 300 mm H × 80 mm DLid: 317 mm W × 309 mm H × 25 mm D |
Mains Supply | 3A internal switch mode power supply, Nom 27 V DC |
Battery Capacity | 2 × 7Ah 12V VRLA fire rated |
Detection Zones | Single monitored detection zone. EOL – 6k8 |
Twin Wire | Selectable in panel (enables AV devices to be connected to det cct) |
On Board Relays | 1 × Alarm, 1 × Fault, volt free changeover, Max 3A |
Fireman’s Switch Input | Fireman’s control switch input for Open/Close/Auto |
Vent Control Input | Vent control switch input, Open/Close (rocker switch) |
Actuator Output | Reversal actuator control output (2.5A total max) can be configured as a maintained output for a magnetic door |
ACT Spec | Monitoring current limit 1.5 mA O/C >10k S/C <10R |
Inrush Current | 20A for an interval of 2 seconds |
Aux Output | 28V, 2.5A. The Aux output should not be used to control sounders. |
False Alarm Management | Type A |
The Haes SZAOV-1001 is a single zone Automatic Opening Vent control panel designed to manage smoke vents, windows and rooflights in fire and ventilation scenarios.
It supports conventional or twin wire detection and uses the same detection circuit technology as Haes EN54 approved fire control panels.
All vent controls and status indications are located on the front of the panel, making operation clear and intuitive for engineers and building managers.
The panel includes an integral 3A power supply with battery backup to ensure continued operation during mains failure.
Additional functionality such as rain sensors, PIR inputs and BMS integration can be added via a simple plug-in PCB, allowing the system to be tailored to site requirements.
Manufactured in the UK, the SZAOV-1001 is a robust and flexible solution for compliant smoke control applications.
Single zone Automatic Opening Vent control panel
Conventional or twin wire detection compatibility
Integral 3A power supply with battery backup
Front-mounted vent controls and status indications
Fireman’s control inputs for Open, Close and Auto
Monitored actuator output for 24V DC vents or magnets
False alarm management mode to reduce call-outs
Disable and test modes for maintenance
Thermostat input for controlled ventilation mode
Optional PIR, rain sensor and BMS inputs via add-on PCB
UK manufactured and CE certified
Item | Specification |
|---|---|
Enclosure | 1.2 mm Mild Steel IP30. Colour ref: MW334E Interpon powder coat |
Cable Entry | Via 20 mm knockouts located in the top and rear of the cabinet |
Dimensions | Back box: 310 mm W × 300 mm H × 80 mm DLid: 317 mm W × 309 mm H × 25 mm D |
Mains Supply | 3A internal switch mode power supply, Nom 27 V DC |
Battery Capacity | 2 × 7Ah 12V VRLA fire rated |
Detection Zones | Single monitored detection zone. EOL – 6k8 |
Twin Wire | Selectable in panel (enables AV devices to be connected to det cct) |
On Board Relays | 1 × Alarm, 1 × Fault, volt free changeover, Max 3A |
Fireman’s Switch Input | Fireman’s control switch input for Open/Close/Auto |
Vent Control Input | Vent control switch input, Open/Close (rocker switch) |
Actuator Output | Reversal actuator control output (2.5A total max) can be configured as a maintained output for a magnetic door |
ACT Spec | Monitoring current limit 1.5 mA O/C >10k S/C <10R |
Inrush Current | 20A for an interval of 2 seconds |
Aux Output | 28V, 2.5A. The Aux output should not be used to control sounders. |
False Alarm Management | Type A |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.