Code: FDS340/059
INC VAT
Code: FDS340/059
medium-sized buildings requiring 2, 4, or 8-zone configurations. Models include the 13270-02LB (2 zones), 13270-04LB (4 zones), and 13270-08LB (8 zones), offering flexible protection tailored to your site's needs.
Each panel includes a built-in EN54-certified power supply and supports up to 72 hours of standby time when fitted with suitable batteries (sold separately).
Xenex panels are known for their ease of installation and operation, making them a practical choice for installers and end users alike.
Key features include multiple sounder circuits for flexible system design, support for repeater panel outputs, and remote evacuation control. The one-man test mode simplifies commissioning and ongoing maintenance, saving time on site.
The Gent Xenex is an ideal solution for conventional fire alarm systems in offices, retail units, small schools, and commercial premises requiring robust and reliable protection.
Available in 2, 4 or 8 zone configurations
Designed for conventional fire alarm systems
Simple, intuitive LED interface and controls
Supports multiple sounder circuits and repeater panels
Fully compliant with BS 5839-1 and EN 54
Compact steel enclosure with secure access
Ideal for commercial, retail, and industrial sites
Manufactured by Gent, a Honeywell company
Specification | 2 Zones | 4 Zones | 8 Zones |
---|---|---|---|
Maximum Load per Zone | 3mA | 3mA | 3mA |
No. of Sounder Circuits | 2 | 4 | 8 |
Max. Sounder Circuit Load | 500mA per circuit, max 1A combined | 500mA per circuit, max 1A combined | 500mA per circuit, max 1A combined |
Batteries | 2 x 12V, 2.1 Ah min | 2 x 12V, 2.1 Ah min | 2 x 12V, 3.4 Ah |
Battery Standby | 72 hours (1mA per zone + 0.5A sounder load max) | 72 hours (1mA per zone + 0.5A sounder load max) | 72 hours (1mA per zone + 0.5A sounder load max) |
Weight (Approx. with Batteries) | 5.8Kg | 5.8Kg | 6.2Kg |
Cable Type | BS 6387, 2 core, min 1.5mm² CSA | BS 6387, 2 core, min 1.5mm² CSA | BS 6387, 2 core, min 1.5mm² CSA |
Operating Environment | Indoor, 0 - 40ºC | Indoor, 0 - 40ºC | Indoor, 0 - 40ºC |
Class Change Facility | Volt free contact - max distance 100m | Volt free contact - max distance 100m | Volt free contact - max distance 100m |
Approvals | BSI Approved (KM 553763) | BSI Approved (KM 553763) | BSI Approved (KM 553763) |
CPD No | 0086-CPD-553764 | 0086-CPD-553764 | 0086-CPD-553764 |
Relevant Standard | EN54: Parts 2 & 4 | EN54: Parts 2 & 4 | EN54: Parts 2 & 4 |
The Gent Xenex is for conventional (non-addressable) fire alarm systems, where zones are used to identify the area of alarm activation.
It is available in 2, 4 or 8 zone models. Each zone supports multiple detectors or call points, grouped by area.
Yes. It’s ideal for small to medium sites such as shops, offices, schools and small industrial units.
Yes. The panel includes a mains supply and supports rechargeable battery backup to maintain system operation during power cuts.
Yes. The Xenex supports remote repeater panels for alarm and status indication at other locations in the building.
medium-sized buildings requiring 2, 4, or 8-zone configurations. Models include the 13270-02LB (2 zones), 13270-04LB (4 zones), and 13270-08LB (8 zones), offering flexible protection tailored to your site's needs.
Each panel includes a built-in EN54-certified power supply and supports up to 72 hours of standby time when fitted with suitable batteries (sold separately).
Xenex panels are known for their ease of installation and operation, making them a practical choice for installers and end users alike.
Key features include multiple sounder circuits for flexible system design, support for repeater panel outputs, and remote evacuation control. The one-man test mode simplifies commissioning and ongoing maintenance, saving time on site.
The Gent Xenex is an ideal solution for conventional fire alarm systems in offices, retail units, small schools, and commercial premises requiring robust and reliable protection.
Available in 2, 4 or 8 zone configurations
Designed for conventional fire alarm systems
Simple, intuitive LED interface and controls
Supports multiple sounder circuits and repeater panels
Fully compliant with BS 5839-1 and EN 54
Compact steel enclosure with secure access
Ideal for commercial, retail, and industrial sites
Manufactured by Gent, a Honeywell company
Specification | 2 Zones | 4 Zones | 8 Zones |
---|---|---|---|
Maximum Load per Zone | 3mA | 3mA | 3mA |
No. of Sounder Circuits | 2 | 4 | 8 |
Max. Sounder Circuit Load | 500mA per circuit, max 1A combined | 500mA per circuit, max 1A combined | 500mA per circuit, max 1A combined |
Batteries | 2 x 12V, 2.1 Ah min | 2 x 12V, 2.1 Ah min | 2 x 12V, 3.4 Ah |
Battery Standby | 72 hours (1mA per zone + 0.5A sounder load max) | 72 hours (1mA per zone + 0.5A sounder load max) | 72 hours (1mA per zone + 0.5A sounder load max) |
Weight (Approx. with Batteries) | 5.8Kg | 5.8Kg | 6.2Kg |
Cable Type | BS 6387, 2 core, min 1.5mm² CSA | BS 6387, 2 core, min 1.5mm² CSA | BS 6387, 2 core, min 1.5mm² CSA |
Operating Environment | Indoor, 0 - 40ºC | Indoor, 0 - 40ºC | Indoor, 0 - 40ºC |
Class Change Facility | Volt free contact - max distance 100m | Volt free contact - max distance 100m | Volt free contact - max distance 100m |
Approvals | BSI Approved (KM 553763) | BSI Approved (KM 553763) | BSI Approved (KM 553763) |
CPD No | 0086-CPD-553764 | 0086-CPD-553764 | 0086-CPD-553764 |
Relevant Standard | EN54: Parts 2 & 4 | EN54: Parts 2 & 4 | EN54: Parts 2 & 4 |
The Gent Xenex is for conventional (non-addressable) fire alarm systems, where zones are used to identify the area of alarm activation.
It is available in 2, 4 or 8 zone models. Each zone supports multiple detectors or call points, grouped by area.
Yes. It’s ideal for small to medium sites such as shops, offices, schools and small industrial units.
Yes. The panel includes a mains supply and supports rechargeable battery backup to maintain system operation during power cuts.
Yes. The Xenex supports remote repeater panels for alarm and status indication at other locations in the building.
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.