Provide us with a few simple details, and our in-house engineers can produce your zone plan chart.
| Product | Price (ex VAT) | Quantity | Total (ex VAT) |
|---|---|---|---|
|
|
£
ex VAT
|
£0.00
|
We Recommend
Bestseller
Code: FDS300/002
£384.28
INC VAT
Code: FDS300/002
The 4 Zone Fire Alarm Conventional Kit provides a complete fire detection and alarm solution using reliable control equipment and detection devices.
Kit Contents
1 × 4 Zone Conventional Fire Alarm Control Panel
4 × Optical Smoke Detectors
1 × Rate-of-Rise Heat Detector
5 × Diode Bases
2 × Conventional Manual Call Points
2 × Sounders with Deep Bases
2 × 12V 3.2Ah Backup Batteries
Designed for small to medium sized buildings, this kit includes all the essential components required to begin installing a conventional fire alarm system in one convenient package. The 4 zone conventional control panel offers dependable performance, straightforward configuration and a cost-effective solution for many fire alarm installations.
Optical smoke and heat detectors provide accurate fire detection across a wide range of environments. Optical smoke detectors offer early warning of smoke, while the rate-of-rise heat detector monitors temperature changes for areas where smoke detection may not be suitable. Manual call points allow occupants to raise the alarm quickly, while sounders provide clear audible alarm notification throughout the building.
Configured as a traditional 4-wire conventional fire alarm system, the kit separates detection and alarm circuits to provide reliable performance and straightforward installation.
Suitable for offices, retail units, small commercial premises and residential buildings, this kit offers a practical and cost-effective fire alarm system solution.
Complete 4 zone conventional fire alarm installation kit
4 zone conventional fire alarm control panel
Optical smoke detectors for reliable smoke detection
Rate-of-rise heat detector for temperature based fire detection
Diode bases designed for use with detectors
Manual call points for manual fire alarm activation
Sounders provide clear audible alarm notification
Conventional 4-wire system configuration for straightforward installation
Suitable for commercial and residential fire alarm systems
Backup batteries included for standby power protection
Specification | 4 Zone Panel |
|---|---|
Approvals/Certifications | EN54 Parts 2 & 4 (LPCB), EN54-13 (Kiwa Telefication) |
Mains Supply | 230V 50/60Hz |
Mains Rated Current | 350mA max |
Internal Power Supply | 19V–28.5V (27V nominal), Ripple 7V max |
Total Output Current | 1.5A @ 230Vac (ImaxA eq 146mA) |
Quiescent Current | 25mA (mains failed, internal sounder active) |
Max Battery Size & Type | 2 x 12V 3.2Ah VRLA (Min. 1.2Ah) |
No. of Detector Zones | 4 (Max. 500m per circuit) |
Call Point Resistor Value | 470 to 680Ω |
Max Devices per Zone | Same |
No. of Sounder Circuits | 4 (Max. 500m per circuit) |
EOL Resistor Value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Alarm Voltage | 27V max, 20V min |
Max Sounder Output Current | 4 x 200mA (800mA total) |
Auxiliary Relays | 2: Aux. Fire & Fault, volt-free SPCO, 1A @ 30Vdc |
Open Collector Outputs | 2: Reset & Remote, 30mA max sink, 30V open circuit |
Other Outputs | 24V Aux Power, resettable fuse, 100mA min hold |
Auxiliary Inputs | 2: Class Change & Alert, 27V max input |
Engineer Functions | Coincidence, 1-man test, programmable delays, zone & sounder behaviour settings |
Expansion Connections | Yes – repeater/network/relay/sounder interface board compatible |
Product Dimensions (mm) | 380 W x 235 H x 96 D (Flush: 367 W x 220 H x 75 D) |
Construction & Finish | Plastic lid/base, RAL7035 textured |
IP Rating | IP30 |
Weight | 1.75kg (without batteries) |
Operating Conditions | -5ºC to +40ºC, 95% RH max |
The 4 Zone Fire Alarm Conventional Kit provides a complete fire detection and alarm solution using reliable control equipment and detection devices.
Kit Contents
1 × 4 Zone Conventional Fire Alarm Control Panel
4 × Optical Smoke Detectors
1 × Rate-of-Rise Heat Detector
5 × Diode Bases
2 × Conventional Manual Call Points
2 × Sounders with Deep Bases
2 × 12V 3.2Ah Backup Batteries
Designed for small to medium sized buildings, this kit includes all the essential components required to begin installing a conventional fire alarm system in one convenient package. The 4 zone conventional control panel offers dependable performance, straightforward configuration and a cost-effective solution for many fire alarm installations.
Optical smoke and heat detectors provide accurate fire detection across a wide range of environments. Optical smoke detectors offer early warning of smoke, while the rate-of-rise heat detector monitors temperature changes for areas where smoke detection may not be suitable. Manual call points allow occupants to raise the alarm quickly, while sounders provide clear audible alarm notification throughout the building.
Configured as a traditional 4-wire conventional fire alarm system, the kit separates detection and alarm circuits to provide reliable performance and straightforward installation.
Suitable for offices, retail units, small commercial premises and residential buildings, this kit offers a practical and cost-effective fire alarm system solution.
Complete 4 zone conventional fire alarm installation kit
4 zone conventional fire alarm control panel
Optical smoke detectors for reliable smoke detection
Rate-of-rise heat detector for temperature based fire detection
Diode bases designed for use with detectors
Manual call points for manual fire alarm activation
Sounders provide clear audible alarm notification
Conventional 4-wire system configuration for straightforward installation
Suitable for commercial and residential fire alarm systems
Backup batteries included for standby power protection
Specification | 4 Zone Panel |
|---|---|
Approvals/Certifications | EN54 Parts 2 & 4 (LPCB), EN54-13 (Kiwa Telefication) |
Mains Supply | 230V 50/60Hz |
Mains Rated Current | 350mA max |
Internal Power Supply | 19V–28.5V (27V nominal), Ripple 7V max |
Total Output Current | 1.5A @ 230Vac (ImaxA eq 146mA) |
Quiescent Current | 25mA (mains failed, internal sounder active) |
Max Battery Size & Type | 2 x 12V 3.2Ah VRLA (Min. 1.2Ah) |
No. of Detector Zones | 4 (Max. 500m per circuit) |
Call Point Resistor Value | 470 to 680Ω |
Max Devices per Zone | Same |
No. of Sounder Circuits | 4 (Max. 500m per circuit) |
EOL Resistor Value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Alarm Voltage | 27V max, 20V min |
Max Sounder Output Current | 4 x 200mA (800mA total) |
Auxiliary Relays | 2: Aux. Fire & Fault, volt-free SPCO, 1A @ 30Vdc |
Open Collector Outputs | 2: Reset & Remote, 30mA max sink, 30V open circuit |
Other Outputs | 24V Aux Power, resettable fuse, 100mA min hold |
Auxiliary Inputs | 2: Class Change & Alert, 27V max input |
Engineer Functions | Coincidence, 1-man test, programmable delays, zone & sounder behaviour settings |
Expansion Connections | Yes – repeater/network/relay/sounder interface board compatible |
Product Dimensions (mm) | 380 W x 235 H x 96 D (Flush: 367 W x 220 H x 75 D) |
Construction & Finish | Plastic lid/base, RAL7035 textured |
IP Rating | IP30 |
Weight | 1.75kg (without batteries) |
Operating Conditions | -5ºC to +40ºC, 95% RH max |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.