Provide us with a few simple details, and our in-house engineers can produce your zone plan chart.
| Product | Price (ex VAT) | Quantity | Total (ex VAT) |
|---|---|---|---|
|
|
£
ex VAT
|
£0.00
|
1 item added to basket
Gent Vigilon S4-34440-02 Mains Powered Four Channel Interface
Code: FDS341/009
INC VAT
Code: FDS341/009
The Gent Vigilon S4-34440-02 Mains Powered Four Channel Interface provides a reliable method of connecting ancillary equipment to a Gent Vigilon fire alarm system where devices cannot be directly integrated onto the loop.
This interface allows external equipment such as plant shutdown systems, ventilation controls, dampers and other building services to be monitored or controlled by the fire alarm system. With four independently programmable channels, the unit offers flexible configuration options to suit a wide range of fire safety applications.
The interface incorporates an EN54-4 compliant power supply within the enclosure, providing a cost-effective solution that reduces installation complexity by housing all required elements in a single unit. This helps simplify installation and minimise maintenance requirements.
Designed for use with Gent Vigilon addressable systems, the S4-34440-02 enables seamless integration between the fire alarm system and external building management equipment.
Mains powered interface 2.0AHR for Gent Vigilon fire alarm systems
Four independently programmable interface channels
Enables connection of ancillary equipment not directly supported on the loop
Integrated EN54-4 compliant power supply
Suitable for controlling or monitoring external building services
Cost-effective solution with all components housed in one enclosure
Helps reduce installation and maintenance time
Designed for integration with Gent Vigilon addressable systems
Specification | Details |
|---|---|
Standards Designed to Meet | EN54 Part 4:1998, EN54 Part 17:2005, EN54 Part 18:2005 |
Overall Dimensions | 478mm x 322mm x 145mm |
Assembled Weight (Approx.) | 5.25kg (excluding batteries and optional components) |
Enclosure | Steel |
Colour | RAL7024 Graphite Grey (fine textured) |
Storage Temperature | -20°C to +70°C |
Ambient Operating Temperature | -5°C to +40°C |
Relative Humidity (Non Condensing) | Up to 95% (Temperature +5°C to +40°C) |
Ingress Protection | IP30 (estimated) |
Mains Voltage | 230V -15% +10%, 50Hz / 60Hz |
Rated Current | 0.7A |
Input Modes | Input can be fault monitored, voltage free contacts or conventional detection zone |
Zone Nominal Voltage | 16V or 22.5V (default ±5%) |
Zone Quiescent Current | 20mA per zone (default) |
Zone Short Circuit Current | Limited to <30mA |
EN54 Compliance Limitation | Maximum of 32 devices per zone |
Addressable Devices | Maximum of 20 diode bases per zone |
Output Modes | Outputs monitored 24V (nominal) 0.5A or LED drive |
Confirmation Modes | All inputs and outputs can be configured as confirmation channels |
Batteries (Two Types) | PS-1221FR – 2 x 12V 2.1Ah (1kg each) for S4-34440-02PS-12120FR – 2 x 12V 12Ah (4.31kg each) for S4-34440-12 |
Compatible Systems | Vigilon (MCC v4.43+ / v3.97), LPC (v4.41 / v3.97), Nano (v2.50), Commissioning Tool (2.2.x) |
Operating Voltage | 35V – 48V |
Model | Imax A | Imax B | Ri max |
|---|---|---|---|
S4-34440-02 | 1.5A | 1.5A | 2.5Ω |
S4-34440-12 | 1.5A | 2.5A | 1.3Ω |
Parameter | Value |
|---|---|
Vmax | 48V |
Vnom | 40V |
Vmin | 24V |
IC max | 0.8A |
IS max | 1.25A |
IL max | 50µA |
ZC max | 0.35Ω |
VSO max | 16V |
VSO min | 8V |
The Gent Vigilon S4-34440-02 Mains Powered Four Channel Interface provides a reliable method of connecting ancillary equipment to a Gent Vigilon fire alarm system where devices cannot be directly integrated onto the loop.
This interface allows external equipment such as plant shutdown systems, ventilation controls, dampers and other building services to be monitored or controlled by the fire alarm system. With four independently programmable channels, the unit offers flexible configuration options to suit a wide range of fire safety applications.
The interface incorporates an EN54-4 compliant power supply within the enclosure, providing a cost-effective solution that reduces installation complexity by housing all required elements in a single unit. This helps simplify installation and minimise maintenance requirements.
Designed for use with Gent Vigilon addressable systems, the S4-34440-02 enables seamless integration between the fire alarm system and external building management equipment.
Mains powered interface 2.0AHR for Gent Vigilon fire alarm systems
Four independently programmable interface channels
Enables connection of ancillary equipment not directly supported on the loop
Integrated EN54-4 compliant power supply
Suitable for controlling or monitoring external building services
Cost-effective solution with all components housed in one enclosure
Helps reduce installation and maintenance time
Designed for integration with Gent Vigilon addressable systems
Specification | Details |
|---|---|
Standards Designed to Meet | EN54 Part 4:1998, EN54 Part 17:2005, EN54 Part 18:2005 |
Overall Dimensions | 478mm x 322mm x 145mm |
Assembled Weight (Approx.) | 5.25kg (excluding batteries and optional components) |
Enclosure | Steel |
Colour | RAL7024 Graphite Grey (fine textured) |
Storage Temperature | -20°C to +70°C |
Ambient Operating Temperature | -5°C to +40°C |
Relative Humidity (Non Condensing) | Up to 95% (Temperature +5°C to +40°C) |
Ingress Protection | IP30 (estimated) |
Mains Voltage | 230V -15% +10%, 50Hz / 60Hz |
Rated Current | 0.7A |
Input Modes | Input can be fault monitored, voltage free contacts or conventional detection zone |
Zone Nominal Voltage | 16V or 22.5V (default ±5%) |
Zone Quiescent Current | 20mA per zone (default) |
Zone Short Circuit Current | Limited to <30mA |
EN54 Compliance Limitation | Maximum of 32 devices per zone |
Addressable Devices | Maximum of 20 diode bases per zone |
Output Modes | Outputs monitored 24V (nominal) 0.5A or LED drive |
Confirmation Modes | All inputs and outputs can be configured as confirmation channels |
Batteries (Two Types) | PS-1221FR – 2 x 12V 2.1Ah (1kg each) for S4-34440-02PS-12120FR – 2 x 12V 12Ah (4.31kg each) for S4-34440-12 |
Compatible Systems | Vigilon (MCC v4.43+ / v3.97), LPC (v4.41 / v3.97), Nano (v2.50), Commissioning Tool (2.2.x) |
Operating Voltage | 35V – 48V |
Model | Imax A | Imax B | Ri max |
|---|---|---|---|
S4-34440-02 | 1.5A | 1.5A | 2.5Ω |
S4-34440-12 | 1.5A | 2.5A | 1.3Ω |
Parameter | Value |
|---|---|
Vmax | 48V |
Vnom | 40V |
Vmin | 24V |
IC max | 0.8A |
IS max | 1.25A |
IL max | 50µA |
ZC max | 0.35Ω |
VSO max | 16V |
VSO min | 8V |
FDS340/059P
FDS340/051
FDS340/212
FDS100/352
FDS600/034
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.