C-TEC 2 Zone AlarmSense Bi-Wire Fire Alarm Kit
We Recommend
Bestseller
Code: FDS600/001
INC VAT
Code: FDS600/001
The C-TEC 2 Zone AlarmSense Bi-Wire Fire Alarm Kit provides a straightforward solution for starting a conventional fire alarm installation.
Kit Contains
1 × C-TEC CFP 2 Zone AlarmSense Bi-Wire Fire Alarm Panel
3 × Apollo 55000-392APO AlarmSense Optical Smoke Detector with Sounder Base
1 × Apollo 55000-196APO AlarmSense A1R Heat Detector with Sounder Base
2 × Apollo 55400-894APO AlarmSense Manual Call Points
2 × 12V 2.1Ah Backup Batteries
Built around the C-TEC AlarmSense control panel and Apollo AlarmSense field devices, the system allows both detectors and sounders to be installed on the same two-core circuit. This bi-wire technology simplifies wiring, reduces installation time and helps keep installation costs down.
The kit includes smoke detection, heat detection, manual call points and standby batteries, providing installers with the core components needed to establish dependable fire detection and alarm signalling.
With two detection zones, the system is suitable for smaller premises where a reliable and easy-to-install fire alarm system is required.
Complete 2 zone conventional fire alarm kit
AlarmSense bi-wire technology allows detectors and sounders on the same circuit
Reduced cabling requirements for faster installation
C-TEC CFP control panel certified to EN54-2 and EN54-4
Optical smoke detection with integrated sounder base
A1R heat detection with integrated sounder base
Manual call points for manual alarm activation
Supplied with standby batteries for backup power
Suitable for small commercial and residential installations
C-TEC CFP 2 Zone AlarmSense Bi-Wire Fire Alarm Panel Technical Detail | |
|---|---|
Approvals/certifications | Certified to EN54-2 & 4 by the LPCB. |
Mains supply | 230V 50/60Hz. |
Mains rated current | 350mA maximum. |
Internal power supply | 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault). |
Total output current limited to | 1.5A @ 230Vac (ImaxA eq 146mA). |
Quiescent current | 25mA (mains failed, internal sounder active, PSU & gen fault LED lit) |
Max battery size and type | 2 x 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah. |
No. of detector zone circuits | The CFP702-2 has 2 AlarmSense zone circuits which are compatible with Apollo's AlarmSense range of detectors & call points AND sounders & visual indicators. (Max. length per circuit is 500m). |
Call point resistor value | Only use AlarmSense call points. |
Max. devices per detector zone | 25 AlarmSense detectors/manual call points per AlarmSense zone. For AlarmSense sounder limitations per AlarmSense zone see 'Max. sounder output current' section. |
No. of conventional sounder circuits | 4 – these are additional conventional (non-AlarmSense) sounder circuits; Max. length per circuit is 500m. |
EOL resistor value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold). |
Alarm voltage | 27V max, 20V min (final battery voltage) |
Auxiliary relays | Two: (1) Aux. Fire; (2) Fault. Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc. |
Open collector outputs | Two: (1) Reset (Active during reset cycle); (2) Remote (Active during any unsilenced fire condition provided all relevant delays have expired). Max. sink current 30mA, Max. open circuit volt |
Other outputs | 24V Aux. Power (Protected by a resettable fuse. 100mA min. hold current. Resets when fault removed). |
Auxiliary inputs | Two: (1) ‘Class Change’ (constant sounders); (2) Alert (pulsed sounders). Connect to 0V to trigger, Max. input voltage 27V (non-latching) |
Engineer (AL3) functions | Program coincidence (double knock); Invoke One Man Walk Test; Program delays; Set up zones for non-latching operation; Program sounders to resound (or not resound) |
Expansion connections | Yes – for optional network driver cards (one required per repeater system), relay output cards and EN54-13 sounder circuit interface boards. |
Product dimensions (mm) | 380 W x 235 H x D 96mm (hole required for flush mounting = 367 W x 220 H x 75 D mm. No bezel required). |
Construction & finish | Plastic lid and base; RAL7035 textured |
IP Rating | IP30. |
Weight | 1.75kg (without batteries) |
The kit contains:
1 x C-TEC CFP702-2 Two Zone AlarmSense Panel
3 x Apollo AlarmSense Optical Smoke Detectors with Sounder Bases
1 x Apollo AlarmSense A1R Heat Detector with Sounder Base
1 x Apollo AlarmSense Manual Call Point
2 x 12V 2.1Ah Backup Batteries
Yes, it’s ideal for both commercial and residential premises, including HMOs, small offices, shops, and shared housing.
AlarmSense is a protocol by Apollo that allows the connection of multiple device types (e.g. detectors, sounders, call points) on the same zone wiring, with the ability to distinguish between them.
Yes, the kit comes with 2 x 12V 2.1Ah backup batteries to maintain operation during a mains power failure.
No, this system requires AlarmSense-compatible devices throughout each zone to function correctly.
The C-TEC 2 Zone AlarmSense Bi-Wire Fire Alarm Kit provides a straightforward solution for starting a conventional fire alarm installation.
Kit Contains
1 × C-TEC CFP 2 Zone AlarmSense Bi-Wire Fire Alarm Panel
3 × Apollo 55000-392APO AlarmSense Optical Smoke Detector with Sounder Base
1 × Apollo 55000-196APO AlarmSense A1R Heat Detector with Sounder Base
2 × Apollo 55400-894APO AlarmSense Manual Call Points
2 × 12V 2.1Ah Backup Batteries
Built around the C-TEC AlarmSense control panel and Apollo AlarmSense field devices, the system allows both detectors and sounders to be installed on the same two-core circuit. This bi-wire technology simplifies wiring, reduces installation time and helps keep installation costs down.
The kit includes smoke detection, heat detection, manual call points and standby batteries, providing installers with the core components needed to establish dependable fire detection and alarm signalling.
With two detection zones, the system is suitable for smaller premises where a reliable and easy-to-install fire alarm system is required.
Complete 2 zone conventional fire alarm kit
AlarmSense bi-wire technology allows detectors and sounders on the same circuit
Reduced cabling requirements for faster installation
C-TEC CFP control panel certified to EN54-2 and EN54-4
Optical smoke detection with integrated sounder base
A1R heat detection with integrated sounder base
Manual call points for manual alarm activation
Supplied with standby batteries for backup power
Suitable for small commercial and residential installations
C-TEC CFP 2 Zone AlarmSense Bi-Wire Fire Alarm Panel Technical Detail | |
|---|---|
Approvals/certifications | Certified to EN54-2 & 4 by the LPCB. |
Mains supply | 230V 50/60Hz. |
Mains rated current | 350mA maximum. |
Internal power supply | 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault). |
Total output current limited to | 1.5A @ 230Vac (ImaxA eq 146mA). |
Quiescent current | 25mA (mains failed, internal sounder active, PSU & gen fault LED lit) |
Max battery size and type | 2 x 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah. |
No. of detector zone circuits | The CFP702-2 has 2 AlarmSense zone circuits which are compatible with Apollo's AlarmSense range of detectors & call points AND sounders & visual indicators. (Max. length per circuit is 500m). |
Call point resistor value | Only use AlarmSense call points. |
Max. devices per detector zone | 25 AlarmSense detectors/manual call points per AlarmSense zone. For AlarmSense sounder limitations per AlarmSense zone see 'Max. sounder output current' section. |
No. of conventional sounder circuits | 4 – these are additional conventional (non-AlarmSense) sounder circuits; Max. length per circuit is 500m. |
EOL resistor value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold). |
Alarm voltage | 27V max, 20V min (final battery voltage) |
Auxiliary relays | Two: (1) Aux. Fire; (2) Fault. Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc. |
Open collector outputs | Two: (1) Reset (Active during reset cycle); (2) Remote (Active during any unsilenced fire condition provided all relevant delays have expired). Max. sink current 30mA, Max. open circuit volt |
Other outputs | 24V Aux. Power (Protected by a resettable fuse. 100mA min. hold current. Resets when fault removed). |
Auxiliary inputs | Two: (1) ‘Class Change’ (constant sounders); (2) Alert (pulsed sounders). Connect to 0V to trigger, Max. input voltage 27V (non-latching) |
Engineer (AL3) functions | Program coincidence (double knock); Invoke One Man Walk Test; Program delays; Set up zones for non-latching operation; Program sounders to resound (or not resound) |
Expansion connections | Yes – for optional network driver cards (one required per repeater system), relay output cards and EN54-13 sounder circuit interface boards. |
Product dimensions (mm) | 380 W x 235 H x D 96mm (hole required for flush mounting = 367 W x 220 H x 75 D mm. No bezel required). |
Construction & finish | Plastic lid and base; RAL7035 textured |
IP Rating | IP30. |
Weight | 1.75kg (without batteries) |
The kit contains:
1 x C-TEC CFP702-2 Two Zone AlarmSense Panel
3 x Apollo AlarmSense Optical Smoke Detectors with Sounder Bases
1 x Apollo AlarmSense A1R Heat Detector with Sounder Base
1 x Apollo AlarmSense Manual Call Point
2 x 12V 2.1Ah Backup Batteries
Yes, it’s ideal for both commercial and residential premises, including HMOs, small offices, shops, and shared housing.
AlarmSense is a protocol by Apollo that allows the connection of multiple device types (e.g. detectors, sounders, call points) on the same zone wiring, with the ability to distinguish between them.
Yes, the kit comes with 2 x 12V 2.1Ah backup batteries to maintain operation during a mains power failure.
No, this system requires AlarmSense-compatible devices throughout each zone to function correctly.
FDS361/003
FDS600/002
FDS600/003
FDS560/001
FDS361/009
FDS400/004
FDS361/004
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.