Book your manufacturer training with Fire Detection Shop today
Product | Price (ex VAT) | Quantity | Total (ex VAT) |
---|---|---|---|
|
£
ex VAT
|
£0.00
|
We Recommend
Bestseller
Code: FDS600/001
INC VAT
Code: FDS600/001
The C-TEC 2 Zone AlarmSense Bi-Wire Fire Alarm Kit provides everything needed to start an installation in a single package.
Featuring a C-TEC AlarmSense panel and Apollo AlarmSense field devices, this system is perfect for conventional installations where detectors and sounders share the same two-core cable.
By integrating combined detectors and sounders, the kit allows for a more discreet setup without compromising sound coverage, ensuring effective alarm distribution throughout the building.
Ideal for commercial and residential applications, it offers a reliable and efficient fire detection solution.
What's in the kit:
1 x C-TEC CFP702-2 Two Zone AlarmSense Bi-Wire Fire Alarm Panel: An alarm panel that is LPCB certified to the latest revisions of EN54 parts 2 and 4, and offers an array of user and installer-friendly features at a very competitive price.
3 x Apollo 55000-392APO AlarmSense Optical Smoke Detector with Sounder Base: This detector changes to alarm state at a pre-set threshold of smoke penetration into the sensing chamber. Comes with a sounder base, providing an audible signal and detection.
1 x Apollo 55000-196APO AlarmSense A1R Standard Heat Detector with Sounder Base: A detector with a fixed upper temperature limit of 57 °C but in addition will detect sudden increases in temperature of 12- 15 °C per minute. Comes with a sounder base, providing audible signal and detection.
1 x Apollo 55400-894APO AlarmSense Manual Call Point: A Manual Call Point that uses push button operation and features a redesigned reset mechanism.
2 x 12vdc 2.1Ah Backup Batteries: 12v 3.2Ah batteries are specifically designed for use throughout the fire and security industries.
Category | Specification |
---|---|
Approvals/Certifications | Certified to EN54-2 & 4 by the LPCB. |
Mains Supply | 230V 50/60Hz. |
Mains Rated Current | 350mA maximum. |
Internal Power Supply | 19V-28.5V (27V nominal). |
Total Output Current Limited to | 1.5A @ 230Vac |
Quiescent Current | 25mA (mains failed, internal sounder active, PSU & gen fault LED lit). |
Max Battery Size and Type | 2 x 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah. |
Detector Zone Circuits | AlarmSense zone circuits compatible with Apollo's AlarmSense range of detectors, call points, sounders, and visual indicators (Max. length per circuit is 500m). |
Call Point Resistor Value | Only use AlarmSense call points. |
Max Devices per Detector Zone | 25 A/S detectors or 32 A/S Detectors and A/S manual call points per AlarmSense zone. |
Conventional Sounder Circuits | 4 Conventional sounder circuits, max 40 sounders, max cable length 500m. |
Sounder EOL Resistor Value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold). |
Alarm Voltage | 27V max, 20V min (final battery voltage). |
Auxiliary Relays | Two: (1) Aux. Fire; (2) Fault. Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc. |
Open Collector Outputs | Two: (1) Reset (Active during reset cycle); (2) Remote (Active during any unsilenced fire condition provided all relevant delays have expired). Max. sink current 30mA, Max. open circuit voltage. |
Other Outputs | 24V Aux. Power (Protected by a resettable fuse. 100mA min. hold current. Resets when fault removed). |
Auxiliary Inputs | Two: (1) ‘Class Change’ (constant sounders); (2) Alert (pulsed sounders). Connect to 0V to trigger, Max. input voltage 27V (non-latching). |
Engineer (AL3) Functions | Program coincidence (double knock); Invoke One Man Walk Test; Program delays; Set up zones for non-latching operation; Program sounders to resound (or not resound) when a new zone enters alarm. |
Expansion Connections | Yes – for optional network driver cards (one required per repeater system), relay output cards, and EN54-13 sounder circuit interface boards. |
Product Dimensions (mm) | 380 W x 235 H x D 96mm (hole required for flush mounting = 367 W x 220 H x 75 D mm. No bezel required). |
The kit contains:
1 x C-TEC CFP702-2 Two Zone AlarmSense Panel
3 x Apollo AlarmSense Optical Smoke Detectors with Sounder Bases
1 x Apollo AlarmSense A1R Heat Detector with Sounder Base
1 x Apollo AlarmSense Manual Call Point
2 x 12V 2.1Ah Backup Batteries
Yes, it’s ideal for both commercial and residential premises, including HMOs, small offices, shops, and shared housing.
AlarmSense is a protocol by Apollo that allows the connection of multiple device types (e.g. detectors, sounders, call points) on the same zone wiring, with the ability to distinguish between them.
Yes, the kit comes with 2 x 12V 2.1Ah backup batteries to maintain operation during a mains power failure.
No, this system requires AlarmSense-compatible devices throughout each zone to function correctly.
The C-TEC 2 Zone AlarmSense Bi-Wire Fire Alarm Kit provides everything needed to start an installation in a single package.
Featuring a C-TEC AlarmSense panel and Apollo AlarmSense field devices, this system is perfect for conventional installations where detectors and sounders share the same two-core cable.
By integrating combined detectors and sounders, the kit allows for a more discreet setup without compromising sound coverage, ensuring effective alarm distribution throughout the building.
Ideal for commercial and residential applications, it offers a reliable and efficient fire detection solution.
What's in the kit:
1 x C-TEC CFP702-2 Two Zone AlarmSense Bi-Wire Fire Alarm Panel: An alarm panel that is LPCB certified to the latest revisions of EN54 parts 2 and 4, and offers an array of user and installer-friendly features at a very competitive price.
3 x Apollo 55000-392APO AlarmSense Optical Smoke Detector with Sounder Base: This detector changes to alarm state at a pre-set threshold of smoke penetration into the sensing chamber. Comes with a sounder base, providing an audible signal and detection.
1 x Apollo 55000-196APO AlarmSense A1R Standard Heat Detector with Sounder Base: A detector with a fixed upper temperature limit of 57 °C but in addition will detect sudden increases in temperature of 12- 15 °C per minute. Comes with a sounder base, providing audible signal and detection.
1 x Apollo 55400-894APO AlarmSense Manual Call Point: A Manual Call Point that uses push button operation and features a redesigned reset mechanism.
2 x 12vdc 2.1Ah Backup Batteries: 12v 3.2Ah batteries are specifically designed for use throughout the fire and security industries.
Category | Specification |
---|---|
Approvals/Certifications | Certified to EN54-2 & 4 by the LPCB. |
Mains Supply | 230V 50/60Hz. |
Mains Rated Current | 350mA maximum. |
Internal Power Supply | 19V-28.5V (27V nominal). |
Total Output Current Limited to | 1.5A @ 230Vac |
Quiescent Current | 25mA (mains failed, internal sounder active, PSU & gen fault LED lit). |
Max Battery Size and Type | 2 x 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah. |
Detector Zone Circuits | AlarmSense zone circuits compatible with Apollo's AlarmSense range of detectors, call points, sounders, and visual indicators (Max. length per circuit is 500m). |
Call Point Resistor Value | Only use AlarmSense call points. |
Max Devices per Detector Zone | 25 A/S detectors or 32 A/S Detectors and A/S manual call points per AlarmSense zone. |
Conventional Sounder Circuits | 4 Conventional sounder circuits, max 40 sounders, max cable length 500m. |
Sounder EOL Resistor Value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold). |
Alarm Voltage | 27V max, 20V min (final battery voltage). |
Auxiliary Relays | Two: (1) Aux. Fire; (2) Fault. Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc. |
Open Collector Outputs | Two: (1) Reset (Active during reset cycle); (2) Remote (Active during any unsilenced fire condition provided all relevant delays have expired). Max. sink current 30mA, Max. open circuit voltage. |
Other Outputs | 24V Aux. Power (Protected by a resettable fuse. 100mA min. hold current. Resets when fault removed). |
Auxiliary Inputs | Two: (1) ‘Class Change’ (constant sounders); (2) Alert (pulsed sounders). Connect to 0V to trigger, Max. input voltage 27V (non-latching). |
Engineer (AL3) Functions | Program coincidence (double knock); Invoke One Man Walk Test; Program delays; Set up zones for non-latching operation; Program sounders to resound (or not resound) when a new zone enters alarm. |
Expansion Connections | Yes – for optional network driver cards (one required per repeater system), relay output cards, and EN54-13 sounder circuit interface boards. |
Product Dimensions (mm) | 380 W x 235 H x D 96mm (hole required for flush mounting = 367 W x 220 H x 75 D mm. No bezel required). |
The kit contains:
1 x C-TEC CFP702-2 Two Zone AlarmSense Panel
3 x Apollo AlarmSense Optical Smoke Detectors with Sounder Bases
1 x Apollo AlarmSense A1R Heat Detector with Sounder Base
1 x Apollo AlarmSense Manual Call Point
2 x 12V 2.1Ah Backup Batteries
Yes, it’s ideal for both commercial and residential premises, including HMOs, small offices, shops, and shared housing.
AlarmSense is a protocol by Apollo that allows the connection of multiple device types (e.g. detectors, sounders, call points) on the same zone wiring, with the ability to distinguish between them.
Yes, the kit comes with 2 x 12V 2.1Ah backup batteries to maintain operation during a mains power failure.
No, this system requires AlarmSense-compatible devices throughout each zone to function correctly.
FDS361/003
FDS600/002
FDS600/003
FDS560/001
FDS361/009
FDS400/004
FDS361/004
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.