C-TEC 16 Zone One Loop Addressable Fire Alarm System Builder | CAST Protocol
Code: FDS440/332
INC VAT
Code: FDS440/332
The C-TEC 16 Zone One Loop Addressable Fire Alarm System Builder is centred around the C-TEC XFP single loop control panel, delivering a reliable and scalable solution for commercial fire detection systems.
Designed around the CAST protocol, this system supports C-TEC CAST field devices, allowing full addressable control with clear device identification and efficient system management.
The XFP panel provides strong performance at a competitive price point, making it suitable for schools, offices, retail premises and light industrial sites.
Integrated keypad and key switch access enables Levels 2 and 3 entry, supporting secure operation and configuration.
The panel is third-party certified to EN54-2 and EN54-4 by the LPCB, ensuring compliance with recognised fire safety standards.
Two programmable conventional sounder circuits and two programmable inputs offer flexibility for system design.
A fault relay and three programmable voltage-free relay outputs provide options for interfacing with other building systems.
Batteries are included for straightforward installation.
Use the options above to configure your custom system build and streamline the ordering process.
16 zone single loop addressable system
C-TEC XFP control panel included
CAST protocol compatible
LPCB certified to EN54-2 and EN54-4
Two programmable sounder circuits
Two programmable inputs
Fault relay and three voltage-free relay outputs
Keypad and key switch access Levels 2 and 3
Batteries included
Configurable system builder format
Feature | Specification |
|---|---|
Approvals/certifications | EN54-2 & 4 by the LPCB |
Protocol/compatibility | C-TEC CAST |
Mains supply | 230V 50/60Hz |
Mains rated current | 350mA maximum |
Internal power supply | 27Vdc nominal |
Total output current | 1.4A @ 230Vac (Imax.A 210mA; Imin. 40mA) |
Quiescent current | 50mA (loop unloaded) |
Battery size and type | 2 x 12V 3.2Ah VRLA connected in series |
No. of loop drivers | 1 |
Max. loop output current | 500mA (25V min; 34V max) |
Max. loop length | 1KM |
Max. addressable devices per loop | 126 |
Conventional sounder circuits | 2 (Max. length per circuit is 500m) |
EOL resistor value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Max. sounder output current | 400mA |
Auxiliary relays | 3 x Programmable Relays, 1 x Fault Relay (active when no faults are present) |
Max. switch current/voltage | 1A / 30Vdc |
Other outputs | 24V Aux. Power (19.5V min, 28V max) Protected by a resettable fuse, Max. current 100mA |
Auxiliary inputs | 2 x Programmable Inputs. Connect to 0V to trigger, Max. input voltage 27V (non-latching) |
PC connection | Via RS232 molex connector (supplied in XFP507 upload/download software kit) |
Indicators | 2 line x 40 character backlit display, 16 Zonal LEDs |
Connections | Fixed, largest acceptable conductor size 1mm² |
Expansion connections | 2-wire RS485 non-redundant network/repeater connection available via optional XFP761 network card |
Product dimensions | 380 W x 235 H x D 96mm |
Construction & finish | Plastic lid and base; RAL7035 textured |
IP Rating | IP30 |
Weight | 1.8kg (without batteries) |
Operating conditions/temperature | -5ºC to +40ºC. Max relative humidity: 95% |
The C-TEC 16 Zone One Loop Addressable Fire Alarm System Builder is centred around the C-TEC XFP single loop control panel, delivering a reliable and scalable solution for commercial fire detection systems.
Designed around the CAST protocol, this system supports C-TEC CAST field devices, allowing full addressable control with clear device identification and efficient system management.
The XFP panel provides strong performance at a competitive price point, making it suitable for schools, offices, retail premises and light industrial sites.
Integrated keypad and key switch access enables Levels 2 and 3 entry, supporting secure operation and configuration.
The panel is third-party certified to EN54-2 and EN54-4 by the LPCB, ensuring compliance with recognised fire safety standards.
Two programmable conventional sounder circuits and two programmable inputs offer flexibility for system design.
A fault relay and three programmable voltage-free relay outputs provide options for interfacing with other building systems.
Batteries are included for straightforward installation.
Use the options above to configure your custom system build and streamline the ordering process.
16 zone single loop addressable system
C-TEC XFP control panel included
CAST protocol compatible
LPCB certified to EN54-2 and EN54-4
Two programmable sounder circuits
Two programmable inputs
Fault relay and three voltage-free relay outputs
Keypad and key switch access Levels 2 and 3
Batteries included
Configurable system builder format
Feature | Specification |
|---|---|
Approvals/certifications | EN54-2 & 4 by the LPCB |
Protocol/compatibility | C-TEC CAST |
Mains supply | 230V 50/60Hz |
Mains rated current | 350mA maximum |
Internal power supply | 27Vdc nominal |
Total output current | 1.4A @ 230Vac (Imax.A 210mA; Imin. 40mA) |
Quiescent current | 50mA (loop unloaded) |
Battery size and type | 2 x 12V 3.2Ah VRLA connected in series |
No. of loop drivers | 1 |
Max. loop output current | 500mA (25V min; 34V max) |
Max. loop length | 1KM |
Max. addressable devices per loop | 126 |
Conventional sounder circuits | 2 (Max. length per circuit is 500m) |
EOL resistor value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Max. sounder output current | 400mA |
Auxiliary relays | 3 x Programmable Relays, 1 x Fault Relay (active when no faults are present) |
Max. switch current/voltage | 1A / 30Vdc |
Other outputs | 24V Aux. Power (19.5V min, 28V max) Protected by a resettable fuse, Max. current 100mA |
Auxiliary inputs | 2 x Programmable Inputs. Connect to 0V to trigger, Max. input voltage 27V (non-latching) |
PC connection | Via RS232 molex connector (supplied in XFP507 upload/download software kit) |
Indicators | 2 line x 40 character backlit display, 16 Zonal LEDs |
Connections | Fixed, largest acceptable conductor size 1mm² |
Expansion connections | 2-wire RS485 non-redundant network/repeater connection available via optional XFP761 network card |
Product dimensions | 380 W x 235 H x D 96mm |
Construction & finish | Plastic lid and base; RAL7035 textured |
IP Rating | IP30 |
Weight | 1.8kg (without batteries) |
Operating conditions/temperature | -5ºC to +40ºC. Max relative humidity: 95% |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.