The Apollo Soteria SA5100-700APO is an isolating optical and heat multisensor detector designed to deliver flexible and reliable fire detection within intelligent addressable systems.
It combines advanced PureLight optical sensing technology with dual thermistors, allowing the detector to be configured for smoke detection, heat detection or a combined response depending on the application. This makes it suitable for environments where a single sensing method may not provide the most appropriate level of performance.
An integrated short-circuit isolator is built into the detector head to help maintain loop integrity in the event of a wiring fault, supporting system resilience and reducing potential downtime.
The detector is designed for connection to a two-wire loop carrying both data and power, simplifying installation while ensuring full communication with compatible control equipment.
A low-profile housing and 360° tri-colour LED indicator provide clear visual status from any angle, with red for alarm, flashing yellow for fault and green for protocol activity.
As part of the wider Apollo Soteria range, this multisensor detector offers consistent performance and compatibility across modern fire alarm installations.
Apollo SA5100-700APO
Integrated short-circuit isolator
10 year warranty
Tri-coloured LED status indicator
Polycarbonate moulding for colour stability and strength
Tested to exceed EN 54-5 & EN 54-7 standards
100mm diameter
Dual heat sensors
PureLight optical technology reduces false alarms and enhances smoke recognition
Utilises digital CoreProtocol communications
Specification | Details |
|---|---|
Notes | All data is supplied subject to change without notice. Specifications are typical at 24 V, 25°C and 50% RH unless otherwise stated. |
Detection principle | Smoke – Photo-electric light scatteringHeat – Thermistor |
Sensor configuration | Smoke – Chamber with surface-mount infrared emitter and prism. Solid state integrated photo-diode and amplifierHeat – Dual exposed heat sensing elements |
Sampling frequency | Once per second |
Terminal functions (L1 and L2 polarity sensitive) | +L2 – Loop in and out positive–L1 in – Loop isolated negative–L1 out – Loop isolated negative+R – Remote indicator positive connection, internal connection to positive–R – Remote indicator negative connection, 4.7 mA maximum |
Supply voltage (Vmin–Vmax) | 17V – 35 Vdc |
Digital communication | XP95, Discovery and CoreProtocol compatible |
Modulation voltage | 5 V – 13 V peak to peak |
Quiescent current | Isolated detector 350 µA |
Power-up surge current | 560 µA |
Maximum power-up time | 10 seconds |
Alarm current, LED illuminated | 3.5 mA |
Clean-air analogue value (excluding Mode 5) | 23 +4/-0 |
Alarm level analogue value | 55 |
Status indicator | Alarm – RedFault – Flashing YellowIsolate – YellowPoll – Green |
Operating temperature | –40°C to 70°C |
Humidity | 0% to 95% RH, no condensation or icing |
Effect of atmospheric pressure | None |
Effect of wind speed | None, tested up to 10 m/s |
Vibration, impact and shock | EN 54-5:2017 and EN 54-7:2018 |
IP rating | IP44 |
Standards and approvals | EN 54-5:2017, EN 54-7:2018 |
Dimensions | 100 mm diameter x 38.5 mm height |
Weight | 96 g, +/- 10% |
Materials | Housing: White flame-retardant polycarbonateTerminals: Nickel plated stainless steel |
The Apollo Soteria SA5100-700APO is an isolating optical and heat multisensor detector designed to deliver flexible and reliable fire detection within intelligent addressable systems.
It combines advanced PureLight optical sensing technology with dual thermistors, allowing the detector to be configured for smoke detection, heat detection or a combined response depending on the application. This makes it suitable for environments where a single sensing method may not provide the most appropriate level of performance.
An integrated short-circuit isolator is built into the detector head to help maintain loop integrity in the event of a wiring fault, supporting system resilience and reducing potential downtime.
The detector is designed for connection to a two-wire loop carrying both data and power, simplifying installation while ensuring full communication with compatible control equipment.
A low-profile housing and 360° tri-colour LED indicator provide clear visual status from any angle, with red for alarm, flashing yellow for fault and green for protocol activity.
As part of the wider Apollo Soteria range, this multisensor detector offers consistent performance and compatibility across modern fire alarm installations.
Apollo SA5100-700APO
Integrated short-circuit isolator
10 year warranty
Tri-coloured LED status indicator
Polycarbonate moulding for colour stability and strength
Tested to exceed EN 54-5 & EN 54-7 standards
100mm diameter
Dual heat sensors
PureLight optical technology reduces false alarms and enhances smoke recognition
Utilises digital CoreProtocol communications
Specification | Details |
|---|---|
Notes | All data is supplied subject to change without notice. Specifications are typical at 24 V, 25°C and 50% RH unless otherwise stated. |
Detection principle | Smoke – Photo-electric light scatteringHeat – Thermistor |
Sensor configuration | Smoke – Chamber with surface-mount infrared emitter and prism. Solid state integrated photo-diode and amplifierHeat – Dual exposed heat sensing elements |
Sampling frequency | Once per second |
Terminal functions (L1 and L2 polarity sensitive) | +L2 – Loop in and out positive–L1 in – Loop isolated negative–L1 out – Loop isolated negative+R – Remote indicator positive connection, internal connection to positive–R – Remote indicator negative connection, 4.7 mA maximum |
Supply voltage (Vmin–Vmax) | 17V – 35 Vdc |
Digital communication | XP95, Discovery and CoreProtocol compatible |
Modulation voltage | 5 V – 13 V peak to peak |
Quiescent current | Isolated detector 350 µA |
Power-up surge current | 560 µA |
Maximum power-up time | 10 seconds |
Alarm current, LED illuminated | 3.5 mA |
Clean-air analogue value (excluding Mode 5) | 23 +4/-0 |
Alarm level analogue value | 55 |
Status indicator | Alarm – RedFault – Flashing YellowIsolate – YellowPoll – Green |
Operating temperature | –40°C to 70°C |
Humidity | 0% to 95% RH, no condensation or icing |
Effect of atmospheric pressure | None |
Effect of wind speed | None, tested up to 10 m/s |
Vibration, impact and shock | EN 54-5:2017 and EN 54-7:2018 |
IP rating | IP44 |
Standards and approvals | EN 54-5:2017, EN 54-7:2018 |
Dimensions | 100 mm diameter x 38.5 mm height |
Weight | 96 g, +/- 10% |
Materials | Housing: White flame-retardant polycarbonateTerminals: Nickel plated stainless steel |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.