The Apollo 55000-393APO AlarmSense Integrating Optical Smoke Detector Base & Sounder Set combines intelligent optical detection with integrated audible signalling in a single, coordinated package.
This set includes the Apollo 55000-391 Integrating Optical Smoke Detector and a compatible AlarmSense sounder base, providing detection and local alarm notification from one device location. The integrating optical detector is specifically designed for environments where transient smoke or brief contamination may occur, helping to reduce unwanted alarms by monitoring and filtering short-term smoke sources before signalling.
When activated, the sounder base delivers a clear audible warning with selectable volume levels, ensuring effective notification at the point of detection.
As part of the AlarmSense range, the unit connects to a simple two-wire circuit shared by detectors, sounders and call points, reducing cabling requirements and streamlining installation.
Apollo 55000-393APO
Responds well to slow-burning, smouldering fires
Well suited for bedrooms and escape routes
360 visibility of LEDs
Reduces false alarms
Quick and simple installation
AlarmSense priority/non priority signal recognition
Detects the removal of a detector head and reports a fault
Quick and simple installation
Provides audible signal and detection at one point
High and low volume ranges
Specification | Value |
|---|---|
Detection principle | Photo-electric detection of light scattered by smoke particles over a wide range of angles |
Sampling frequency | Once every four seconds |
Supply voltage | 9 Vdc to 33 Vdc |
Supply wiring | Two wire supply, polarity insensitive |
Quiescent current at 15 V | < 50 µA |
Alarm current (2–8.5 V) | < 1.5 mA |
Alarm current (10.5–15 V) | 25 ± 2 mA |
Alarm current (18–24 V) | < 1.5 mA |
Alarm current (33 V) | < 2 mA |
Maximum reset voltage | 2 V |
Reset time | 1 second |
Maximum supply interruption time | 40 ms |
Operating temperature | -10°C to +55°C |
Humidity | 0% to 95% RH (no condensation or icing) |
IP Rating | Designed to IP44 |
Standards and approvals | EN 54-7, CPR, FG |
Dimensions | 100 mm diameter × 42 mm height |
Dimensions in base | 100 mm diameter × 50 mm height |
Weight | 90 g (detector) |
Materials – Housing | White flame-retardant polycarbonate |
Materials – Terminals | Nickel plated stainless steel |
The Apollo 55000-393APO AlarmSense Integrating Optical Smoke Detector Base & Sounder Set combines intelligent optical detection with integrated audible signalling in a single, coordinated package.
This set includes the Apollo 55000-391 Integrating Optical Smoke Detector and a compatible AlarmSense sounder base, providing detection and local alarm notification from one device location. The integrating optical detector is specifically designed for environments where transient smoke or brief contamination may occur, helping to reduce unwanted alarms by monitoring and filtering short-term smoke sources before signalling.
When activated, the sounder base delivers a clear audible warning with selectable volume levels, ensuring effective notification at the point of detection.
As part of the AlarmSense range, the unit connects to a simple two-wire circuit shared by detectors, sounders and call points, reducing cabling requirements and streamlining installation.
Apollo 55000-393APO
Responds well to slow-burning, smouldering fires
Well suited for bedrooms and escape routes
360 visibility of LEDs
Reduces false alarms
Quick and simple installation
AlarmSense priority/non priority signal recognition
Detects the removal of a detector head and reports a fault
Quick and simple installation
Provides audible signal and detection at one point
High and low volume ranges
Specification | Value |
|---|---|
Detection principle | Photo-electric detection of light scattered by smoke particles over a wide range of angles |
Sampling frequency | Once every four seconds |
Supply voltage | 9 Vdc to 33 Vdc |
Supply wiring | Two wire supply, polarity insensitive |
Quiescent current at 15 V | < 50 µA |
Alarm current (2–8.5 V) | < 1.5 mA |
Alarm current (10.5–15 V) | 25 ± 2 mA |
Alarm current (18–24 V) | < 1.5 mA |
Alarm current (33 V) | < 2 mA |
Maximum reset voltage | 2 V |
Reset time | 1 second |
Maximum supply interruption time | 40 ms |
Operating temperature | -10°C to +55°C |
Humidity | 0% to 95% RH (no condensation or icing) |
IP Rating | Designed to IP44 |
Standards and approvals | EN 54-7, CPR, FG |
Dimensions | 100 mm diameter × 42 mm height |
Dimensions in base | 100 mm diameter × 50 mm height |
Weight | 90 g (detector) |
Materials – Housing | White flame-retardant polycarbonate |
Materials – Terminals | Nickel plated stainless steel |
FDS100/437
FDS100/438
FDS340/033
FDS410/042
FDS410/043
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.