The Identi-Cryer Lockdown Control Panel is a dedicated emergency alert solution designed to coordinate lockdown procedures across buildings of all sizes.
Whether responding to internal threats, perimeter breaches, or nearby external risks, this panel provides clear and reliable notification control to ensure the safety of building occupants.
Available in 2, 4, or 8-zone models (IC3/2/230, IC3/4/230, IC3/8/230), the panel supports targeted or site-wide lockdown messaging with simple activation.
Built for continuous protection, it actively monitors for system faults 24/7 and offers up to 72 hours of battery standby, maintaining performance during power outages.
Designed for ease of use and straightforward installation, it also features common fault and alarm relay contacts, making it easy to integrate with wider building management or fire safety systems.
Key Features:
Available in 2, 4, or 8-zone configurations
Continuous 24-hour system fault monitoring
Up to 72-hour battery standby for enhanced resilience
Common fault and alarm relay outputs for easy integration
Simple to install and maintain
Supports a full lockdown notification strategy
Ideal for schools, offices, public buildings and commercial sites, the Identi-Cryer Lockdown Control Panel provides peace of mind and structured control in any emergency.
Available in 2, 4, or 8-zone configurations
Continuous 24-hour system fault monitoring
Up to 72-hour battery standby for enhanced resilience
Common fault and alarm relay outputs for easy integration
Simple to install and maintain
Supports a full lockdown notification strategy
Specification | Details |
---|---|
Mains Supply | 230 Vac (100 Watts Max) |
Mains Supply Fuse | 4 A - 250 V Slow Blow – 20 mm |
Output Voltage | 28.5 nominal Vdc |
Battery Size Max | 12 Vdc 7Ah (2 Batteries) |
Dedicated Sounder Circuits | 2 x 24 Vdc, fused at 500 mA |
Aux. Relay Output | 1 x Fire, 1 x Fault (NO, NC, C) |
Relay Contact Rating | 50 Vdc – 2 A resistive loads |
Detection Circuit EOL | Active EOL – Capacitor |
Sounder Circuit EOL | 10K Ohms, 0.25 W |
IP Rating | 30 |
Operating Temperature | -10°C to 50°C |
Construction | Fire Rated ABS |
Colour | White |
Dimensions (HxWxD) | 404 x 272 x 107 mm |
Weight | 1.7 Kg |
The Identi-Cryer Lockdown Control Panel is a dedicated emergency alert solution designed to coordinate lockdown procedures across buildings of all sizes.
Whether responding to internal threats, perimeter breaches, or nearby external risks, this panel provides clear and reliable notification control to ensure the safety of building occupants.
Available in 2, 4, or 8-zone models (IC3/2/230, IC3/4/230, IC3/8/230), the panel supports targeted or site-wide lockdown messaging with simple activation.
Built for continuous protection, it actively monitors for system faults 24/7 and offers up to 72 hours of battery standby, maintaining performance during power outages.
Designed for ease of use and straightforward installation, it also features common fault and alarm relay contacts, making it easy to integrate with wider building management or fire safety systems.
Key Features:
Available in 2, 4, or 8-zone configurations
Continuous 24-hour system fault monitoring
Up to 72-hour battery standby for enhanced resilience
Common fault and alarm relay outputs for easy integration
Simple to install and maintain
Supports a full lockdown notification strategy
Ideal for schools, offices, public buildings and commercial sites, the Identi-Cryer Lockdown Control Panel provides peace of mind and structured control in any emergency.
Available in 2, 4, or 8-zone configurations
Continuous 24-hour system fault monitoring
Up to 72-hour battery standby for enhanced resilience
Common fault and alarm relay outputs for easy integration
Simple to install and maintain
Supports a full lockdown notification strategy
Specification | Details |
---|---|
Mains Supply | 230 Vac (100 Watts Max) |
Mains Supply Fuse | 4 A - 250 V Slow Blow – 20 mm |
Output Voltage | 28.5 nominal Vdc |
Battery Size Max | 12 Vdc 7Ah (2 Batteries) |
Dedicated Sounder Circuits | 2 x 24 Vdc, fused at 500 mA |
Aux. Relay Output | 1 x Fire, 1 x Fault (NO, NC, C) |
Relay Contact Rating | 50 Vdc – 2 A resistive loads |
Detection Circuit EOL | Active EOL – Capacitor |
Sounder Circuit EOL | 10K Ohms, 0.25 W |
IP Rating | 30 |
Operating Temperature | -10°C to 50°C |
Construction | Fire Rated ABS |
Colour | White |
Dimensions (HxWxD) | 404 x 272 x 107 mm |
Weight | 1.7 Kg |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.