System Sensor 22051TE-26 Multi-Sensor Detector
Code: FDS201/211
£44.76
INC VAT
Code: FDS201/211
The System Sensor 22051TE-26 is an addressable photoelectric smoke and thermal multi-criteria fire detector from the Series 200 Advanced range. It combines photoelectric smoke sensing with thermal detection in a single plug-in device, using embedded software to manage both sensing elements as one detector. This approach provides enhanced false alarm immunity while supporting faster response across a wide range of developing fire conditions.
The thermal element uses thermistor technology with a software-corrected linear temperature response. The detector conforms to EN54-5 as a 58°C fixed temperature and rate-of-rise thermal detector, while the smoke sensing element conforms to EN54-7.
Sensitivity thresholds for the sensing elements can be controlled from the fire alarm panel, allowing detector behaviour to be adapted to the requirements of the protected area. It can also be programmed to operate in heat-only mode during periods when normal activities may otherwise cause unwanted alarms, before reverting to full photo-thermal operation during unoccupied periods.
Two integral tri-colour LEDs provide 360° local status indication using red, amber and green, with static or blinking indications available. Rotary decade address switches support straightforward device addressing, while the Series 200 Advanced Protocol provides enhanced device control and management. The detector is mechanically and electrically backwards compatible with existing Series 200 plus devices and is suitable for use with B501AP Series and specified B500 Series bases.
Thermal assistance to the core photoelectric smoke detector to provide enhanced false alarm immunity
Faster response to a wide range of incipient fires
Combines two separate sensing elements that are managed by embedded software to act as a single unit
Series 200 advanced protocol included
Tri-colour LED offering red, green and amber colours
Rotary decade address switches
Pure white colour to compliment modern buildings
100% mechanical and electrical backwards compatibility
Complete with isolator
Specification | Details |
|---|---|
Model | 22051TE |
Operating Voltage Range | 15 to 32Vdc |
Maximum Standby Current | 200μA at 24VDC (no communications) / 300μA at 24VDC (LED blink enabled, once every 5s) |
LED Current | Red: 3.5mA at 24Vdc; Green: 7.0mA @ 24Vdc; Yellow: 10.5mA @ 24Vdc |
Remote Output Voltage | 22.5Vdc @ 24Vdc |
Remote Output Current | 10.8mA @ 24Vdc |
Additional Loop Resistance Using B501AP | typ 20mohm (max 30 mohm) |
Temperature Range | -30°C to +80°C |
Normal Ambient Temperature Limit | Do not install where normal ambient temperature exceeds 50°C |
Humidity | 10 to 93% relative humidity, non-condensing |
Height | 61mm installed in B501AP base |
Diameter | 102mm installed in B501AP base |
Weight | 99g including base |
Maximum Wire Gauge For Terminals | 2.5mm² |
Colour | White |
Material | PC/ABS |
Alarm Level 1 | 1%/ft smoke |
Alarm Level 2 | Adjusting 1% - 2%/ft smoke |
Alarm Level 3 | 2%/ft smoke |
Alarm Level 4 | Adjusting 2% - 3.5%/ft smoke |
Alarm Level 5 | 3%/ft smoke |
Alarm Level 6 | ClassA1R |
Compatible Bases | B501AP Series, B500 Series (B501, B501DG, B524RTE, B524HTR, B524IEFT-1) |
Thermal Standard | EN54-5 |
Smoke Standard | EN54-7 |
Thermal Detection | 58°C fixed temperature and rate of rise |
Environmental Compliance | WEEE and RoHS legislative requirements |
The System Sensor 22051TE-26 is an addressable photoelectric smoke and thermal multi-criteria fire detector from the Series 200 Advanced range. It combines photoelectric smoke sensing with thermal detection in a single plug-in device, using embedded software to manage both sensing elements as one detector. This approach provides enhanced false alarm immunity while supporting faster response across a wide range of developing fire conditions.
The thermal element uses thermistor technology with a software-corrected linear temperature response. The detector conforms to EN54-5 as a 58°C fixed temperature and rate-of-rise thermal detector, while the smoke sensing element conforms to EN54-7.
Sensitivity thresholds for the sensing elements can be controlled from the fire alarm panel, allowing detector behaviour to be adapted to the requirements of the protected area. It can also be programmed to operate in heat-only mode during periods when normal activities may otherwise cause unwanted alarms, before reverting to full photo-thermal operation during unoccupied periods.
Two integral tri-colour LEDs provide 360° local status indication using red, amber and green, with static or blinking indications available. Rotary decade address switches support straightforward device addressing, while the Series 200 Advanced Protocol provides enhanced device control and management. The detector is mechanically and electrically backwards compatible with existing Series 200 plus devices and is suitable for use with B501AP Series and specified B500 Series bases.
Thermal assistance to the core photoelectric smoke detector to provide enhanced false alarm immunity
Faster response to a wide range of incipient fires
Combines two separate sensing elements that are managed by embedded software to act as a single unit
Series 200 advanced protocol included
Tri-colour LED offering red, green and amber colours
Rotary decade address switches
Pure white colour to compliment modern buildings
100% mechanical and electrical backwards compatibility
Complete with isolator
Specification | Details |
|---|---|
Model | 22051TE |
Operating Voltage Range | 15 to 32Vdc |
Maximum Standby Current | 200μA at 24VDC (no communications) / 300μA at 24VDC (LED blink enabled, once every 5s) |
LED Current | Red: 3.5mA at 24Vdc; Green: 7.0mA @ 24Vdc; Yellow: 10.5mA @ 24Vdc |
Remote Output Voltage | 22.5Vdc @ 24Vdc |
Remote Output Current | 10.8mA @ 24Vdc |
Additional Loop Resistance Using B501AP | typ 20mohm (max 30 mohm) |
Temperature Range | -30°C to +80°C |
Normal Ambient Temperature Limit | Do not install where normal ambient temperature exceeds 50°C |
Humidity | 10 to 93% relative humidity, non-condensing |
Height | 61mm installed in B501AP base |
Diameter | 102mm installed in B501AP base |
Weight | 99g including base |
Maximum Wire Gauge For Terminals | 2.5mm² |
Colour | White |
Material | PC/ABS |
Alarm Level 1 | 1%/ft smoke |
Alarm Level 2 | Adjusting 1% - 2%/ft smoke |
Alarm Level 3 | 2%/ft smoke |
Alarm Level 4 | Adjusting 2% - 3.5%/ft smoke |
Alarm Level 5 | 3%/ft smoke |
Alarm Level 6 | ClassA1R |
Compatible Bases | B501AP Series, B500 Series (B501, B501DG, B524RTE, B524HTR, B524IEFT-1) |
Thermal Standard | EN54-5 |
Smoke Standard | EN54-7 |
Thermal Detection | 58°C fixed temperature and rate of rise |
Environmental Compliance | WEEE and RoHS legislative requirements |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.