Provide us with a few simple details, and our in-house engineers can produce your zone plan chart.
| Product | Price (ex VAT) | Quantity | Total (ex VAT) |
|---|---|---|---|
|
|
£
ex VAT
|
£0.00
|
We Recommend
Bestseller
Code: FDS372/444
INC VAT
Code: FDS372/444
The Kentec 4 Zone Conventional Fire Alarm Kit – Orbis provides a reliable fire detection and alarm solution using the trusted Kentec Sigma control panel and Apollo Orbis detection devices.
Kit Contents
1 × Kentec Sigma KL11040M2 4 Zone Conventional Fire Alarm Control Panel
4 × Apollo ORB-OP-12001-APO Orbis Optical Smoke Detectors
1 × Apollo ORB-HT-11002-APO Orbis A2S Fixed Temperature Heat Detector
5 × Apollo ORB-DB-00003-APO Orbis Diode Bases
2 × FireSmart Conventional Manual Call Points
2 × FireSmart Conventional Sounders with Deep Bases
1 × FireSmart 12V 3.2Ah Trade Battery Twin Pack
Designed for small to medium sized buildings, this kit contains the core components required to begin a conventional fire alarm installation in one convenient package. The Kentec Sigma KL11040M2 control panel offers four detection zones and is known for its robust metal enclosure, simple configuration and dependable performance.
Apollo Orbis detectors provide fast and reliable fire detection, with optical smoke detection for early warning and heat detection for environments where smoke detectors may not be suitable. Combined with FireSmart manual call points and sounders, the system ensures clear audible alarm notification throughout the building.
Configured as a traditional 4-wire conventional fire alarm system, the kit separates detection and alarm circuits to provide dependable performance and straightforward installation.
Suitable for offices, retail units, small commercial premises and residential buildings, this kit offers a practical and cost-effective fire alarm system solution.
Complete 4 zone conventional fire alarm kit with Apollo Orbis detectors
Kentec Sigma conventional fire alarm control panel with metal enclosure
Apollo Orbis optical smoke detectors for reliable smoke detection
Fixed temperature heat detector for temperature based fire detection
Manual call points for manual fire alarm activation
FireSmart sounders provide clear audible alarm notification
Conventional 4-wire system configuration for straightforward installation
Suitable for commercial and residential fire alarm systems
Includes diode bases for Apollo Orbis detectors
Backup batteries included for standby power protection
Specification | Details |
|---|---|
Construction | 1.2mm mild sheet steel |
IP Rating | IP30 |
Finish | Epoxy powder coated |
Colour (lid & box) | BS 00 A 05 grey - fine texture |
Colour (control panel & labels) | RAL 7047 light grey - satin |
Weight | 6kg |
Supply Voltage | 230V AC (+10%/-15%) |
Mains Supply Fuse | 1.6 Amp 250V |
Power Supply DC Rating | 24V 3 Amps |
Maximum Battery Size | 7Ah 12V (2 per panel) |
Fault Contract Rating | 30V DC 1 Amp |
Local Fire Contract Rating | 30V DC 1 Amp |
Fire Contract Rating | 30V DC 1 Amp |
Sounder Output Rating | 0.5A per output (max 1.6A overall) |
Detection Zone Current | 1.6 milliamps |
Detection Zone EOL Resistor | 6k8 5% |
Active EOL | K14606K (optional) |
Sounder Output EOL Resistor | 10k 5% |
Cable Capacity | 2.5mm² per terminal |
Operating Temperature | -5°C to +40°C |
Operating Humidity | <95% (non-condensing) |
The Kentec 4 Zone Conventional Fire Alarm Kit – Orbis provides a reliable fire detection and alarm solution using the trusted Kentec Sigma control panel and Apollo Orbis detection devices.
Kit Contents
1 × Kentec Sigma KL11040M2 4 Zone Conventional Fire Alarm Control Panel
4 × Apollo ORB-OP-12001-APO Orbis Optical Smoke Detectors
1 × Apollo ORB-HT-11002-APO Orbis A2S Fixed Temperature Heat Detector
5 × Apollo ORB-DB-00003-APO Orbis Diode Bases
2 × FireSmart Conventional Manual Call Points
2 × FireSmart Conventional Sounders with Deep Bases
1 × FireSmart 12V 3.2Ah Trade Battery Twin Pack
Designed for small to medium sized buildings, this kit contains the core components required to begin a conventional fire alarm installation in one convenient package. The Kentec Sigma KL11040M2 control panel offers four detection zones and is known for its robust metal enclosure, simple configuration and dependable performance.
Apollo Orbis detectors provide fast and reliable fire detection, with optical smoke detection for early warning and heat detection for environments where smoke detectors may not be suitable. Combined with FireSmart manual call points and sounders, the system ensures clear audible alarm notification throughout the building.
Configured as a traditional 4-wire conventional fire alarm system, the kit separates detection and alarm circuits to provide dependable performance and straightforward installation.
Suitable for offices, retail units, small commercial premises and residential buildings, this kit offers a practical and cost-effective fire alarm system solution.
Complete 4 zone conventional fire alarm kit with Apollo Orbis detectors
Kentec Sigma conventional fire alarm control panel with metal enclosure
Apollo Orbis optical smoke detectors for reliable smoke detection
Fixed temperature heat detector for temperature based fire detection
Manual call points for manual fire alarm activation
FireSmart sounders provide clear audible alarm notification
Conventional 4-wire system configuration for straightforward installation
Suitable for commercial and residential fire alarm systems
Includes diode bases for Apollo Orbis detectors
Backup batteries included for standby power protection
Specification | Details |
|---|---|
Construction | 1.2mm mild sheet steel |
IP Rating | IP30 |
Finish | Epoxy powder coated |
Colour (lid & box) | BS 00 A 05 grey - fine texture |
Colour (control panel & labels) | RAL 7047 light grey - satin |
Weight | 6kg |
Supply Voltage | 230V AC (+10%/-15%) |
Mains Supply Fuse | 1.6 Amp 250V |
Power Supply DC Rating | 24V 3 Amps |
Maximum Battery Size | 7Ah 12V (2 per panel) |
Fault Contract Rating | 30V DC 1 Amp |
Local Fire Contract Rating | 30V DC 1 Amp |
Fire Contract Rating | 30V DC 1 Amp |
Sounder Output Rating | 0.5A per output (max 1.6A overall) |
Detection Zone Current | 1.6 milliamps |
Detection Zone EOL Resistor | 6k8 5% |
Active EOL | K14606K (optional) |
Sounder Output EOL Resistor | 10k 5% |
Cable Capacity | 2.5mm² per terminal |
Operating Temperature | -5°C to +40°C |
Operating Humidity | <95% (non-condensing) |
FDS320/235
FDS361/010
FDS130/351
FDS130/450
FDS372/443
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.