Kentec 4 Zone AlarmSense Bi-Wire Fire Alarm Kit
We Recommend
Bestseller
Code: FDS400/005
INC VAT
Code: FDS400/005
The Kentec 4 Zone AlarmSense Bi-Wire Fire Alarm Kit provides a practical solution for starting a conventional fire alarm installation.
Kit Contents:
1 × Kentec KA11040M2 4 Zone AlarmSense Bi-Wire Fire Alarm Panel
3 × Apollo 55000-392APO AlarmSense Optical Smoke Detector with Sounder Base
1 × Apollo 55000-196APO AlarmSense A1R Heat Detector with Sounder Base
2 × Apollo 55040-894APO AlarmSense Manual Call Points
2 × 12V 3.2Ah Backup Batteries
Built around the Kentec AlarmSense control panel and Apollo field devices, the system allows both detectors and sounders to operate on the same two-core circuit. This bi-wire technology simplifies wiring, reduces installation time and helps lower overall installation costs.
The kit includes smoke detection, heat detection, manual call points and standby batteries, providing the core components required to establish dependable fire detection and alarm signalling.
It is well suited to smaller commercial buildings, HMOs and similar premises where a reliable and straightforward fire alarm system is required.
Complete 4 zone conventional fire alarm kit
AlarmSense bi-wire technology allows detectors and sounders on the same circuit
Reduced cabling requirements for faster installation
Kentec AlarmSense control panel with selectable local alarm feature
Optical smoke detection with integrated sounder base
A1R heat detection with integrated sounder base
Manual call points for manual alarm activation
Supplied with standby batteries for backup power
Suitable for HMOs, small commercial buildings and similar applications
Specification | Control Panel Details |
|---|---|
Construction | 1.2mm mild sheet steel |
IP Rating | IP30 |
Finish | Epoxy powder coated |
Colour – lid & box | BS 00 A 05 grey – fine texture |
Colour – control panel & labels | RAL 7047 light grey – satin |
Weight | 6kg |
Supply Voltage | 230V AC (+10% / -15%) |
Mains supply fuse | 1.6 Amp 250V |
Power supply DC rating | 24V 3 Amps |
Maximum battery size | 7Ah 12V (2 per panel) |
Fault contact rating | 30V DC 1 Amp |
Local fire contact rating | 30V DC 1 Amp |
Fire contact rating | 30V DC 1 Amp |
Common Sounder output rating | 0.5A per output (max 1.6A over all outputs) |
AlarmSense Sounder output rating | 0.2A per output |
Detection zone current | 1.6 milliamps |
Detection zone EOL resistor | 3K3 5% |
Sounder output EOL resistor | 10k 5% |
Cable capacity | 2.5mm² per terminal |
Operating temperature | -5°C to +40°C |
Operating humidity | <95% (non condensing) |
The Kentec 4 Zone AlarmSense Bi-Wire Fire Alarm Kit provides a practical solution for starting a conventional fire alarm installation.
Kit Contents:
1 × Kentec KA11040M2 4 Zone AlarmSense Bi-Wire Fire Alarm Panel
3 × Apollo 55000-392APO AlarmSense Optical Smoke Detector with Sounder Base
1 × Apollo 55000-196APO AlarmSense A1R Heat Detector with Sounder Base
2 × Apollo 55040-894APO AlarmSense Manual Call Points
2 × 12V 3.2Ah Backup Batteries
Built around the Kentec AlarmSense control panel and Apollo field devices, the system allows both detectors and sounders to operate on the same two-core circuit. This bi-wire technology simplifies wiring, reduces installation time and helps lower overall installation costs.
The kit includes smoke detection, heat detection, manual call points and standby batteries, providing the core components required to establish dependable fire detection and alarm signalling.
It is well suited to smaller commercial buildings, HMOs and similar premises where a reliable and straightforward fire alarm system is required.
Complete 4 zone conventional fire alarm kit
AlarmSense bi-wire technology allows detectors and sounders on the same circuit
Reduced cabling requirements for faster installation
Kentec AlarmSense control panel with selectable local alarm feature
Optical smoke detection with integrated sounder base
A1R heat detection with integrated sounder base
Manual call points for manual alarm activation
Supplied with standby batteries for backup power
Suitable for HMOs, small commercial buildings and similar applications
Specification | Control Panel Details |
|---|---|
Construction | 1.2mm mild sheet steel |
IP Rating | IP30 |
Finish | Epoxy powder coated |
Colour – lid & box | BS 00 A 05 grey – fine texture |
Colour – control panel & labels | RAL 7047 light grey – satin |
Weight | 6kg |
Supply Voltage | 230V AC (+10% / -15%) |
Mains supply fuse | 1.6 Amp 250V |
Power supply DC rating | 24V 3 Amps |
Maximum battery size | 7Ah 12V (2 per panel) |
Fault contact rating | 30V DC 1 Amp |
Local fire contact rating | 30V DC 1 Amp |
Fire contact rating | 30V DC 1 Amp |
Common Sounder output rating | 0.5A per output (max 1.6A over all outputs) |
AlarmSense Sounder output rating | 0.2A per output |
Detection zone current | 1.6 milliamps |
Detection zone EOL resistor | 3K3 5% |
Sounder output EOL resistor | 10k 5% |
Cable capacity | 2.5mm² per terminal |
Operating temperature | -5°C to +40°C |
Operating humidity | <95% (non condensing) |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.