Book your manufacturer training with Fire Detection Shop today
| Product | Price (ex VAT) | Quantity | Total (ex VAT) |
|---|---|---|---|
|
|
£
ex VAT
|
£0.00
|
Code: FDS121/124
INC VAT
Code: FDS121/124
The Global Fire GEKKO-2 Gekko Addressable Fire Alarm Panel - 2 Loop is the next-generation replacement for the highly successful GFE JUNIOR panel.
GEKKO-2 supports between 1 and 4 addressable loops and is enclosed in a durable ABS plastic housing, secured with just two screws for quick and easy access.
Its new backlit graphic LCD display supports custom characters and symbols, enabling multi-language operation along with customisable visual and pictorial elements.
The panel integrates seamlessly with the ODYSSEY Graphics Interface and can also connect to third-party Building Management Systems via Modbus. In addition, it supports communication with repeater units using any CHAMELEON protocol networking interface.
The enclosure provides space for up to 7Ah 24V DC sealed lead-acid backup batteries, supplying reliable backup power to the GEKKO panel and associated ZEOS devices, which are designed for ultra-low current consumption.
All Cause and Effect programming and customer-specific configurations are created using the CHAMELEON CONNECTOR software and stored directly in the unit’s flash memory.
2 loop panel
Networkable panel, compatible with OCTO+ and NODE+ range of panels
Supports connection to Repeaters via RS422, Fibre-Optic or TCP/IP
250 devices per loop (125 address limit)
Up to 95 VULCAN 2 (addressable) ultra low current base sounders (32 address limit)
32 individually programmable sounder addresses
Full Self-Addressable Devices support
2 Fire output relays (change-over) and 1 Fault relay (NC - opens on fault)
2 conventional alarm outputs (individually programmable)
Both detection loops monitored for integrity
384 fully programmable zones
512 fully programmable sounder groups
512 I/O groups
Event log (rolling, 10000 entries)
Available only with ZEOS protocol
Compatible with all our own low cost ancillary modules
Backlit graphical LCD display of 240x64 pixels
Programming by integrated keypad or Loader PC software
Multiple language support (menu selectable)
Integrated 16 zone LED fire zone indication
Brand | Global Fire Equipment |
Manufacturer Part No. | GEKKO-2 |
Primary Power Source | Mains powered (230V) |
System Type | Addressable |
Number of Loops (Fitted) | 2 |
Number of Zones | 384 |
Protocol Compatibility | GFE ZEOS |
Colour | White |
The Global Fire GEKKO-2 Gekko Addressable Fire Alarm Panel - 2 Loop is the next-generation replacement for the highly successful GFE JUNIOR panel.
GEKKO-2 supports between 1 and 4 addressable loops and is enclosed in a durable ABS plastic housing, secured with just two screws for quick and easy access.
Its new backlit graphic LCD display supports custom characters and symbols, enabling multi-language operation along with customisable visual and pictorial elements.
The panel integrates seamlessly with the ODYSSEY Graphics Interface and can also connect to third-party Building Management Systems via Modbus. In addition, it supports communication with repeater units using any CHAMELEON protocol networking interface.
The enclosure provides space for up to 7Ah 24V DC sealed lead-acid backup batteries, supplying reliable backup power to the GEKKO panel and associated ZEOS devices, which are designed for ultra-low current consumption.
All Cause and Effect programming and customer-specific configurations are created using the CHAMELEON CONNECTOR software and stored directly in the unit’s flash memory.
2 loop panel
Networkable panel, compatible with OCTO+ and NODE+ range of panels
Supports connection to Repeaters via RS422, Fibre-Optic or TCP/IP
250 devices per loop (125 address limit)
Up to 95 VULCAN 2 (addressable) ultra low current base sounders (32 address limit)
32 individually programmable sounder addresses
Full Self-Addressable Devices support
2 Fire output relays (change-over) and 1 Fault relay (NC - opens on fault)
2 conventional alarm outputs (individually programmable)
Both detection loops monitored for integrity
384 fully programmable zones
512 fully programmable sounder groups
512 I/O groups
Event log (rolling, 10000 entries)
Available only with ZEOS protocol
Compatible with all our own low cost ancillary modules
Backlit graphical LCD display of 240x64 pixels
Programming by integrated keypad or Loader PC software
Multiple language support (menu selectable)
Integrated 16 zone LED fire zone indication
Brand | Global Fire Equipment |
Manufacturer Part No. | GEKKO-2 |
Primary Power Source | Mains powered (230V) |
System Type | Addressable |
Number of Loops (Fitted) | 2 |
Number of Zones | 384 |
Protocol Compatibility | GFE ZEOS |
Colour | White |
FDS900/067P
FDS100/456P
FDS100/470P
FDS333/264
FDS600/082
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.