The C-TEC C4403A2 ActiV Fixed Temperature Heat Detector is a precision-engineered Type A2 device designed to trigger an alarm when a static temperature of 60°C is reached.
Ideal for environments where smoke detection is unsuitable, this unit provides dependable heat-based detection with minimal false alarms.
Manufactured in the UK by C-TEC, this detector is third-party certified to EN54-5 by Intertek and built to deliver consistent performance at a cost-effective price.
Operating from 6V to 33V DC, it suits a wide range of conventional fire alarm systems.
Equipped with dual ultra-bright 8mm x 2mm red LEDs, the detector offers 360° visibility, ensuring alarm status is clearly seen from any angle.
Compatible with ActiV C4408, C4408D, and C4408R bases (sold separately), it integrates seamlessly into your fire detection setup.
Fixed temperature detection – Type A2 heat detector activates at a static temperature of 60°C
Consistent performance – High-quality unit designed and manufactured in the UK
EN54-5 certified – Independently approved by Intertek for fire detection compliance
Wide voltage range – Operates between 6V and 33V DC for versatile installation
360° LED indication – Twin 8mm x 2mm red LEDs provide full visual coverage
Base compatibility – Works with ActiV C4408 (standard), C4408D (diode), and C4408R (relay) bases (sold separately)
Specification | Details |
---|---|
Approvals/Certifications | Certified to EN54-5 by Intertek |
Application/Operation | Triggers when temperature reaches between 54°C and 65°C |
Application Temperature | 25°C typical, 50°C max |
Static Response Temperature | 54°C min, 65°C max |
Supply Wiring | 2-wire monitored, polarity sensitive |
Supply/Operating Voltage | 9 to 33V DC |
Quiescent Current | 30μA @ 24 VDC |
Alarm Voltage | 6–33V DC |
Alarm Current | 19mA @ 12–33V DC; 11mA @ 9V DC; 2.5mA @ 6V DC |
Alarm Reset Voltage | Less than 1V DC (+0.5 seconds alarm reset time) |
Expansion Connections | Remote LED output via ActiV base. Current source to negative line, short-circuit protected. Max voltage 2.7V DC |
Product Dimensions (mm) | 102.2mm diameter x 37mm deep (detector in base); 102.2mm diameter x 57.5mm deep |
Construction & Finish | White polycarbonate casing rated to UL94 V-2 with nylon parts |
IP Rating | IP42 |
Weight | 99g |
The C-TEC C4403A2 ActiV Fixed Temperature Heat Detector is a precision-engineered Type A2 device designed to trigger an alarm when a static temperature of 60°C is reached.
Ideal for environments where smoke detection is unsuitable, this unit provides dependable heat-based detection with minimal false alarms.
Manufactured in the UK by C-TEC, this detector is third-party certified to EN54-5 by Intertek and built to deliver consistent performance at a cost-effective price.
Operating from 6V to 33V DC, it suits a wide range of conventional fire alarm systems.
Equipped with dual ultra-bright 8mm x 2mm red LEDs, the detector offers 360° visibility, ensuring alarm status is clearly seen from any angle.
Compatible with ActiV C4408, C4408D, and C4408R bases (sold separately), it integrates seamlessly into your fire detection setup.
Fixed temperature detection – Type A2 heat detector activates at a static temperature of 60°C
Consistent performance – High-quality unit designed and manufactured in the UK
EN54-5 certified – Independently approved by Intertek for fire detection compliance
Wide voltage range – Operates between 6V and 33V DC for versatile installation
360° LED indication – Twin 8mm x 2mm red LEDs provide full visual coverage
Base compatibility – Works with ActiV C4408 (standard), C4408D (diode), and C4408R (relay) bases (sold separately)
Specification | Details |
---|---|
Approvals/Certifications | Certified to EN54-5 by Intertek |
Application/Operation | Triggers when temperature reaches between 54°C and 65°C |
Application Temperature | 25°C typical, 50°C max |
Static Response Temperature | 54°C min, 65°C max |
Supply Wiring | 2-wire monitored, polarity sensitive |
Supply/Operating Voltage | 9 to 33V DC |
Quiescent Current | 30μA @ 24 VDC |
Alarm Voltage | 6–33V DC |
Alarm Current | 19mA @ 12–33V DC; 11mA @ 9V DC; 2.5mA @ 6V DC |
Alarm Reset Voltage | Less than 1V DC (+0.5 seconds alarm reset time) |
Expansion Connections | Remote LED output via ActiV base. Current source to negative line, short-circuit protected. Max voltage 2.7V DC |
Product Dimensions (mm) | 102.2mm diameter x 37mm deep (detector in base); 102.2mm diameter x 57.5mm deep |
Construction & Finish | White polycarbonate casing rated to UL94 V-2 with nylon parts |
IP Rating | IP42 |
Weight | 99g |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.