Provide us with a few simple details, and our in-house engineers can produce your zone plan chart.
| Product | Price (ex VAT) | Quantity | Total (ex VAT) |
|---|---|---|---|
|
|
£
ex VAT
|
£0.00
|
Code: FDS440/334
INC VAT
Code: FDS440/334
Our Addressable Fire Alarm System Builder allows you to customise your fire alarm system using a C-TEC CAST base panel with supplied batteries
C-TEC's XFP larger single loop 32 zone addressable fire alarm panel comes with a metal housing and bigger batteries while still offering high performance at a very competitive price.
Combined keypad / key switch entry to Access Levels 2 and 3
Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB)
Two programmable conventional sounder circuits
Two programmable inputs
Fault output relay and three programmable relay outputs with voltage free changeover contacts
Compatible with C-TEC CAST field devices
Batteries included
Build your customised kit by selecting the number and type of field devices you want from the extras drop down.
Addressable C-TEC panel
Batteries included
Custom fire alarm system builder
C-TEC CAST protocol
Specification | Details |
|---|---|
Approvals/Certifications | Certified to EN54-2 & 4 by the LPCB |
Protocol/Compatibility | C-TEC CAST |
Mains supply | 230V 50/60Hz |
Mains rated current | 680mA maximum |
Internal power supply | 27Vdc nominal |
Total output current | Limited to 3A @ 230Vac (Imax.A 270mA; Imin. 70mA) |
Quiescent current | 100mA (2 loops unloaded) |
Max. battery size and type | 2 x 12V 7Ah VRLA connected in series |
No. of loop drivers | 2 |
Max. loop output current | 500mA (25V min; 34V max) |
Max. loop length | 1KM |
Max. addressable devices per loop | 126 |
No. of conventional sounder circuits | 2 (Max. length per circuit is 500m) |
EOL resistor value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Max. sounder output current | 400mA |
Auxiliary relays | 3 x Programmable Relays, 1 x Fault Relay |
Other outputs | 24V Aux. Power (19.5V min, 28V max), max. current 100mA |
Auxiliary inputs | 2 x Programmable Inputs |
PC connection | Via RS232 molex connector |
Indicators | 2 line x 40 character backlit display, 32 Zonal LEDs |
Connections | Fixed, largest acceptable conductor size 1mm² |
Expansion connections | 2-wire RS485 network/repeater connection via optional AFP711 |
Product dimensions (mm) | 410 W x 250 H x 80 D (base); 439 W x 274 H x 7 D (lid) |
Construction & finish | Metal |
IP Rating | IP30 |
Weight | 4.5kg (without batteries) |
Operating conditions/temperature | -5ºC to +40ºC, max relative humidity: 95% |
Our Addressable Fire Alarm System Builder allows you to customise your fire alarm system using a C-TEC CAST base panel with supplied batteries
C-TEC's XFP larger single loop 32 zone addressable fire alarm panel comes with a metal housing and bigger batteries while still offering high performance at a very competitive price.
Combined keypad / key switch entry to Access Levels 2 and 3
Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB)
Two programmable conventional sounder circuits
Two programmable inputs
Fault output relay and three programmable relay outputs with voltage free changeover contacts
Compatible with C-TEC CAST field devices
Batteries included
Build your customised kit by selecting the number and type of field devices you want from the extras drop down.
Addressable C-TEC panel
Batteries included
Custom fire alarm system builder
C-TEC CAST protocol
Specification | Details |
|---|---|
Approvals/Certifications | Certified to EN54-2 & 4 by the LPCB |
Protocol/Compatibility | C-TEC CAST |
Mains supply | 230V 50/60Hz |
Mains rated current | 680mA maximum |
Internal power supply | 27Vdc nominal |
Total output current | Limited to 3A @ 230Vac (Imax.A 270mA; Imin. 70mA) |
Quiescent current | 100mA (2 loops unloaded) |
Max. battery size and type | 2 x 12V 7Ah VRLA connected in series |
No. of loop drivers | 2 |
Max. loop output current | 500mA (25V min; 34V max) |
Max. loop length | 1KM |
Max. addressable devices per loop | 126 |
No. of conventional sounder circuits | 2 (Max. length per circuit is 500m) |
EOL resistor value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Max. sounder output current | 400mA |
Auxiliary relays | 3 x Programmable Relays, 1 x Fault Relay |
Other outputs | 24V Aux. Power (19.5V min, 28V max), max. current 100mA |
Auxiliary inputs | 2 x Programmable Inputs |
PC connection | Via RS232 molex connector |
Indicators | 2 line x 40 character backlit display, 32 Zonal LEDs |
Connections | Fixed, largest acceptable conductor size 1mm² |
Expansion connections | 2-wire RS485 network/repeater connection via optional AFP711 |
Product dimensions (mm) | 410 W x 250 H x 80 D (base); 439 W x 274 H x 7 D (lid) |
Construction & finish | Metal |
IP Rating | IP30 |
Weight | 4.5kg (without batteries) |
Operating conditions/temperature | -5ºC to +40ºC, max relative humidity: 95% |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.