Provide us with a few simple details, and our in-house engineers can produce your zone plan chart.
| Product | Price (ex VAT) | Quantity | Total (ex VAT) |
|---|---|---|---|
|
|
£
ex VAT
|
£0.00
|
1 item added to basket
C-TEC 32 Zone One Loop Addressable Fire Alarm System Builder | CAST Protocol
We Recommend
Code: FDS440/333
INC VAT
Code: FDS440/333
The C-TEC 32 Zone One Loop Addressable Fire Alarm System Builder enables you to configure a scalable addressable fire alarm system using C-TEC CAST protocol field devices.
This is a flexible system builder, not a fixed kit, allowing you to select detectors, call points, sounders and accessories to match your specific site requirements.
At the core is the larger C-TEC XFP 32 zone single loop control panel, supplied in a metal enclosure with increased battery capacity to support larger installations.
The panel delivers dependable performance for commercial premises while remaining competitively priced.
Third-party certified to EN54-2 and EN54-4 by the LPCB, it provides compliance for professional fire alarm installations.
Integrated keypad and key switch access enables Levels 2 and 3 control for secure system management.
Two programmable conventional sounder circuits, two programmable inputs and multiple voltage-free relay outputs allow flexible interfacing with other building systems.
Use the options above to build a customised system and streamline your project ordering.
32 zone single loop addressable system builder
Based on C-TEC XFP 32 zone control panel
Compatible with C-TEC CAST protocol field devices
LPCB certified to EN54-2 and EN54-4
Metal enclosure with larger battery capacity
Two programmable sounder circuits
Two programmable inputs
Fault relay and three voltage-free relay outputs
Keypad and key switch access Levels 2 and 3
Customisable configuration to suit site requirements
Suitable for medium to larger commercial premises
Feature | Specification |
|---|---|
Approvals/certifications | EN54-2 & 4 by the LPCB |
Protocol/compatibility | C-TEC CAST |
Mains supply | 230V 50/60Hz |
Mains rated current | 350mA maximum |
Internal power supply | 27Vdc nominal |
Total output current | 1.4A @ 230Vac (Imax.A 210mA; Imin. 40mA) |
Quiescent current | 50mA (loop unloaded) |
Battery size and type | 2 x 12V 7.0Ah VRLA connected in series |
No. of loop drivers | 1 |
Max. loop output current | 500mA (25V min; 34V max) |
Max. loop length | 1KM |
Max. addressable devices per loop | 126 |
Conventional sounder circuits | 2 (Max. length per circuit is 500m) |
EOL resistor value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Max. sounder output current | 400mA |
Auxiliary relays | 3 x Programmable Relays, 1 x Fault Relay (active when no faults are present) |
Max. switch current/voltage | 1A / 30Vdc |
Other outputs | 24V Aux. Power (19.5V min, 28V max) Protected by a resettable fuse, Max. current 100mA |
Auxiliary inputs | 2 x Programmable Inputs. Connect to 0V to trigger, Max. input voltage 27V (non-latching) |
PC connection | Via RS232 molex connector (supplied in XFP507 upload/download software kit) |
Indicators | 2 line x 40 character backlit display, 16 Zonal LEDs |
Connections | Fixed, largest acceptable conductor size 1mm² |
Expansion connections | 2-wire RS485 non-redundant network/repeater connection available via optional XFP761 network card |
Product dimensions | 380 W x 235 H x D 96mm |
Construction & finish | Plastic lid and base; RAL7035 textured |
IP Rating | IP30 |
Weight | 1.8kg (without batteries) |
Operating conditions/temperature | -5ºC to +40ºC. Max relative humidity: 95% |
The C-TEC 32 Zone One Loop Addressable Fire Alarm System Builder enables you to configure a scalable addressable fire alarm system using C-TEC CAST protocol field devices.
This is a flexible system builder, not a fixed kit, allowing you to select detectors, call points, sounders and accessories to match your specific site requirements.
At the core is the larger C-TEC XFP 32 zone single loop control panel, supplied in a metal enclosure with increased battery capacity to support larger installations.
The panel delivers dependable performance for commercial premises while remaining competitively priced.
Third-party certified to EN54-2 and EN54-4 by the LPCB, it provides compliance for professional fire alarm installations.
Integrated keypad and key switch access enables Levels 2 and 3 control for secure system management.
Two programmable conventional sounder circuits, two programmable inputs and multiple voltage-free relay outputs allow flexible interfacing with other building systems.
Use the options above to build a customised system and streamline your project ordering.
32 zone single loop addressable system builder
Based on C-TEC XFP 32 zone control panel
Compatible with C-TEC CAST protocol field devices
LPCB certified to EN54-2 and EN54-4
Metal enclosure with larger battery capacity
Two programmable sounder circuits
Two programmable inputs
Fault relay and three voltage-free relay outputs
Keypad and key switch access Levels 2 and 3
Customisable configuration to suit site requirements
Suitable for medium to larger commercial premises
Feature | Specification |
|---|---|
Approvals/certifications | EN54-2 & 4 by the LPCB |
Protocol/compatibility | C-TEC CAST |
Mains supply | 230V 50/60Hz |
Mains rated current | 350mA maximum |
Internal power supply | 27Vdc nominal |
Total output current | 1.4A @ 230Vac (Imax.A 210mA; Imin. 40mA) |
Quiescent current | 50mA (loop unloaded) |
Battery size and type | 2 x 12V 7.0Ah VRLA connected in series |
No. of loop drivers | 1 |
Max. loop output current | 500mA (25V min; 34V max) |
Max. loop length | 1KM |
Max. addressable devices per loop | 126 |
Conventional sounder circuits | 2 (Max. length per circuit is 500m) |
EOL resistor value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
Max. sounder output current | 400mA |
Auxiliary relays | 3 x Programmable Relays, 1 x Fault Relay (active when no faults are present) |
Max. switch current/voltage | 1A / 30Vdc |
Other outputs | 24V Aux. Power (19.5V min, 28V max) Protected by a resettable fuse, Max. current 100mA |
Auxiliary inputs | 2 x Programmable Inputs. Connect to 0V to trigger, Max. input voltage 27V (non-latching) |
PC connection | Via RS232 molex connector (supplied in XFP507 upload/download software kit) |
Indicators | 2 line x 40 character backlit display, 16 Zonal LEDs |
Connections | Fixed, largest acceptable conductor size 1mm² |
Expansion connections | 2-wire RS485 non-redundant network/repeater connection available via optional XFP761 network card |
Product dimensions | 380 W x 235 H x D 96mm |
Construction & finish | Plastic lid and base; RAL7035 textured |
IP Rating | IP30 |
Weight | 1.8kg (without batteries) |
Operating conditions/temperature | -5ºC to +40ºC. Max relative humidity: 95% |
If you’re looking for high quality fire detection, security of fire safety equipment, we are your one-stop-shop for everything you need to get your job done.
Fire Detection Shop has a wide range of products, kits and accessories in stock and ready to ship - so you can place your order now with confidence.
To help you choose the right product, our technical team are on the end of the telephone to answer your questions. Alternatively, you can complete the form here and one of our specialists will call you back.
We have a team of in-house engineers trained to design, install and commission the products we sell. If you’re interested in the services we can provide you with a quotation.
We use cookies to enhance your site experience. Choose your preferences below.